Form No. IRGCEM-1010
9
MAINTENANCE
Cleaning the Air Inlet Filters
The air inlet filters on the bottom of the unit should be removed
and cleaned monthly. Use the following procedure to clean the
filter.
1. Turn off and unplug the unit. Allow the unit to cool.
2. Remove, empty, and clean the grease tray.
3. Remove the side shield.
4. Access the air inlet filters.
• Turn the unit upside down and lay the unit on a soft, non-
scratching surface.
5. For each air inlet filter:
a. Remove the frame screw on the filter frame.
b. Lift the filter frame and air inlet filter off of the unit.
c. Clean the air inlet filter with soapy water.
d. Allow the air inlet filter to dry completely.
e. Place the air inlet filter inside the filter frame and install
onto the bottom of the unit. Install the frame by inserting
the tabs on the filter frame into the tab slots on the
bottom of the unit.
f. Insert the frame screw and tighten securely.
6. Return the unit to the upright position.
7. Reinstall the grease tray and side shield.
Figure 7. Removing the Air Inlet Filters
Frame
Screw
Tab
Filter Frame
Air Inlet Filter
Tab Slot