Model
Voltage
Watts
Amps
Plug Configuration
Shipping Weight
GRSDH-24
120
830
6.9
NEMA 5-15P
51 lbs. (23 kg)
GRSDH-30
120
970
8.1
NEMA 5-15P
58 lbs. (26 kg)
200E
940
4.7
CEE 7/7 Schuko
58 lbs. (26 kg)
220E
890
4.0
CEE 7/7 Schuko
58 lbs. (26 kg)
240E
1060
4.4
BS-1363
58 lbs. (26 kg)
220-230 (CE)
890-974
4.0-4.2
CEE 7/7 Schuko
58 lbs. (26 kg)
230-240 (CE)
974-1060
4.2-4.4
BS-1363
58 lbs. (26 kg)
GRSDH-36
120
1170
9.8
NEMA 5-15P
66 lbs. (30 kg)
220E
1074
4.9
CEE 7/7 Schuko
66 lbs. (30 kg)
240E
1278
5.3
BS-1363
66 lbs. (30 kg)
220-230 (CE)
1074-1174
4.9-5.1
CEE 7/7 Schuko
66 lbs. (30 kg)
230-240 (CE)
1174-1278
5.1-5.3
BS-1363
66 lbs. (30 kg)
GRSDH-41
120
1340
11.2
NEMA 5-15P
74 lbs. (34 kg)
200E
1180
5.9
No Plug
74 lbs. (34 kg)
220E
1228
5.6
CEE 7/7 Schuko
74 lbs. (34 kg)
240E
1464
6.1
BS-1363
74 lbs. (34 kg)
220-230 (CE)
1228-1343
5.6-5.8
CEE 7/7 Schuko
74 lbs. (34 kg)
230-240 (CE)
1343-1464
5.8-6.1
BS-1363
74 lbs. (34 kg)
GRSDH-52
120
1760
14.7
NEMA 5-15*
86 lbs. (39 kg)
220E
1604
7.3
CEE 7/7 Schuko
86 lbs. (39 kg)
240E
1912
8.0
BS-1363
86 lbs. (39 kg)
220-230 (CE)
1604-1754
7.3-7.6
CEE 7/7 Schuko
86 lbs. (39 kg)
230-240 (CE)
1754-1912
7.6-8.0
BS-1363
86 lbs. (39 kg)
GRSDH-60
120/208-240
2100
15.0
NEMA L14-20P
198 lbs. (90 kg)
220E
1830
8.3
CEE 7/7 Schuko
198 lbs. (90 kg)
240E
2180
9.1
BS-1363
198 lbs. (90 kg)
220-230 (CE)
1830-2001
8.3-8.7
CEE 7/7 Schuko
198 lbs. (90 kg)
230-240 (CE)
2001-2180
8.7-9.1
BS-1363
198 lbs. (90 kg)
Electrical Rating Chart — GRSDH Models, Single Shelf
Plug Configurations
Units are supplied from the factory with an electrical
cord and plug installed (plugs are supplied
according to the applications). Some export units
may require field installation of the proper plug.
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical
outlet of the correct voltage, size, and plug
configuration. If the plug and receptacle do
not match, contact a qualified electrician to
determine and install the proper voltage and
size electrical outlet.
• Units supplied without an electrical plug
require field installation of the proper plug.
Plug must be properly grounded and of the
correct voltage, size, and configuration for
the electrical specifications of the unit.
Contact a qualified electrician to determine
and install the proper electrical plug.
WARNING
Figure 5. Plug Configurations
NOTE: Receptacle not supplied by Hatco.
NEMA 5-15P
CEE 7/7 Schuko
BS-1363
NEMA 5-20P
NEMA L14-20P
NEMA 14-30P
The shaded areas contain electrical information for
Export models only.
SPECIFICATIONS
3
Form No. GRSDM-0708
* NEMA 5-20P for Canada