Hatco Glo-Ray

®

Fry Holding Stations are perfect for holding fried

foods at kitchen work areas and serving areas. These warmers

hold  hot  fried  products  and  keep  them  at  optimum  serving

temperatures without affecting quality. 

The  semi-enclosed  chamber  is  equipped  with  pre-focused

infrared  heat  from  above  and  a  thermostatically-controlled

heated base to extend the holding times of the food product.

The ceramic heating element(s) and the base blanket heating

element are guaranteed against burnout and breakage for one

year.

Each  Hatco  Glo-Ray  Fry  Holding  Station  is  a  product  of

extensive research and field testing. The materials used were

selected for maximum durability, attractive appearance, and

optimum  performance.  Every  unit  is  inspected  and  tested

thoroughly prior to shipment.

This  manual  provides  the  installation,  safety,  and  operating

instructions  for  Glo-Ray  Fry  Holding  Stations.  Hatco

recommends all installation, operating, and safety instructions

appearing in this manual be read prior to installation or operation

of a unit.

Safety information that appears in this manual is identified by

the following signal word panels:

WARNING  indicates  a  hazardous  situation  which,  if  not

avoided, could result in death or serious injury.

CAUTION  indicates  a  hazardous  situation  which,  if  not

avoided, could result in minor or moderate injury.

NOTICE is used to address practices not related to personal

injury.

WARNING

NOTICE

CAUTION

Important Owner Information ..............................................2

Introduction...........................................................................2

Important Safety Instructions..............................................3

Model Descriptions...............................................................4

all models...........................................................................4

Model Designation................................................................4

Specifications........................................................................5

Plug Configurations ............................................................5

Electrical Rating Chart........................................................5

Dimensions.........................................................................6

Installation .............................................................................7

General...............................................................................7

Operation...............................................................................8

General...............................................................................8

Maintenance ..........................................................................8

General...............................................................................8

Cleaning .............................................................................8

Replacing a Display Light Bulb ..........................................8

Troubleshooting Guide ........................................................9

Options and Accessories...................................................10

Limited Warranty.................................................................11

Authorized Parts Distributors............................Back Cover

IMPORTANT OWNER INFORMATION

Record  the  model  number,  serial  number,  voltage,  and

purchase date of the unit in the spaces below (specification

label located on the lower, left-hand side of the unit). Please

have this information available when calling Hatco for service

assistance.

model No. ____________________________________

Serial No. ____________________________________

Voltage ______________________________________

Date of Purchase ______________________________

Register your unit!

Completing online warranty registration will prevent delay in

obtaining warranty coverage. access the Hatco website at

www.hatcocorp.com

, select the 

Parts & Service

pull-down

menu, and click on “Warranty Registration”.

Business

8:00 

am

to 5:00 

Pm

Hours:

Central Standard Time (C.S.T.)

(Summer Hours:  June to September – 
8:00 

am

to 5:00 

Pm

C.S.T. 

monday through Thursday
8:00 

am

to 2:30 

Pm

C.S.T. Friday)

Telephone: (800) 558-0607; (414) 671-6350

E-mail:

[email protected]

Fax:

(800) 690-2966 (Parts and Service)
(414) 671-3976 (International)

additional information can be found by visiting our web site at

www.hatcocorp.com

.

24 Hour 7 Day Parts and Service
Assistance available in the United States
and Canada by calling (800) 558-0607.

Содержание Glo-Ray GRFHS-16

Страница 1: ...instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este pro...

Страница 2: ...NG NOTICE CAUTION Important Owner Information 2 Introduction 2 Important Safety Instructions 3 Model Descriptions 4 all models 4 Model Designation 4 Specifications 5 Plug Configurations 5 Electrical R...

Страница 3: ...zARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and in...

Страница 4: ...ceramic upper heating element s stainless steel trivet with sectional divider and a 6 1829 mm cord and plug set Various options and accessories can be supplied to customize the Fry Holding Station Ref...

Страница 5: ...12 0 NEma 5 15P 64 lbs 29 kg 220 230 CE 1233 1347 5 6 5 9 CEE 7 7 Schuko 64 lbs 29 kg 230 240 CE 1347 1468 5 9 6 1 BS 1363 or aS 3112 64 lbs 29 kg SPECIFICATIONS Form No GRFHSm 0611 5 Plug Configurati...

Страница 6: ...8 701 mm 22 3 4 578 mm 20 1 2 521 mm 23 584 mm GRFHS PTT21 24 15 16 633 mm 38 965 mm 22 5 8 575 mm 18 1 4 464 mm 25 1 4 641 mm GRFHS 22 22 558 mm 18 3 8 466 mm 17 1 4 438 mm 18 7 8 479 mm 15 3 8 391 m...

Страница 7: ...tion for details 2 Remove tape and protective packaging from all surfaces of the unit and any accessories Do not lay unit on the side with the control panel Damage to unit could occur 3 Install the st...

Страница 8: ...a new specially coated incandescent light bulb NOTE Hatco shatter resistant light bulbs meet NSF standards for food holding and display areas For 100 and 120 V units use Hatco P N 02 30 043 00 For 22...

Страница 9: ...ng duct or exhaust fan away from unit Incorrect power supply low Check power supply to unit making sure it matches rating on the unit If power supply is incorrect change to match rating on unit Heatin...

Страница 10: ...g box combo ribbon can be added to the fry bin on either the right or left side Each combo tray can hold up to three fry bags and three fry boxes Nine Pleat Fry Box Bag Combo Ribbon GRFHS PTT21 and PT...

Страница 11: ...RPOSE OR PaTENT OR OTHER INTELLECTUaL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat...

Страница 12: ...n Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Fland...

Отзывы: