background image

FLAv-R-SAvOR

®

Humidified Large Capacity 

Display Cabinets

WFST Series

Installation and Operating Manual

P/N 07.04.248.00

© 2012 Hatco Corporation

Register Online!

(see page 2)

www.hatcocorp.com

Do not operate this equipment unless you

have read and understood the contents of

this  manual!  Failure  to  follow  the

instructions contained in this manual may

result  in  serious  injury  or  death.  This

manual  contains  important  safety

information concerning the maintenance,

use,  and  operation  of  this  product.  If

you’re unable to understand the contents

of  this  manual,  please  bring  it  to  the

attention  of  your  supervisor.  Keep  this

manual  in  a  safe  location  for  future

reference.

No opere este equipo al menos que haya

leído y comprendido el contenido de este

manual! Cualquier falla en el seguimiento

de las instrucciones contenidas en este

manual puede resultar en un serio lesión

o  muerte.  Este  manual  contiene

importante información sobre seguridad

concerniente  al  mantenimiento,  uso  y

operación de este producto. Si usted no

puede  entender  el  contenido  de  este

manual  por  favor  pregunte  a  su

supervisor.  Almacenar  este  manual  en

una localización segura para la referencia

futura.

Ne pas utiliser cet équipement sans avoir

lu et compris le contenu de ce manuel !

Le  non-respect  des  instructions

contenues dans ce manuel peut entraîner

de  graves  blessures  ou  la  mort.  Ce

manuel  contient  des  informations

importantes  concernant  l'entretien,

l'utilisation  et  le  fonctionnement  de  ce

produit.  Si  vous  ne  comprenez  pas  le

contenu de ce manuel, veuillez le signaler

à votre supérieur. Conservez ce manuel

dans un endroit sûr pour pouvoir vous y

référer plus tard.

WARNING

ADVERTENCIA

AVERTISSEMENT

Содержание Flav-R-Savor WFST Series

Страница 1: ...o de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importante informaci n sobre seguridad...

Страница 2: ...mum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 WFST 1X 4 WFST 2X 4 Mode...

Страница 3: ...LECTRIC SHOCK HAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to...

Страница 4: ...ofit Model WFST 1X The WFST 1X is an aluminum cabinet available in black clear anodized or optional Designer colors It features French glass doors on one side and a 4 shelf multi purpose stationary ra...

Страница 5: ...0 8 3 CEE 7 7 Schuko 182 lbs 83 kg 230 240 CE 50 60 1650 1790 7 2 7 5 BS 1363 182 lbs 83 kg Form No WFSTm 0612 5 Plug Configurations Units are supplied from the factory with an electrical cord and pl...

Страница 6: ...32 3 4 831 mm 29 736 mm 19 7 8 504 mm WFST 2X 32 1 8 814 mm 27 5 8 703 mm 32 3 4 831 mm 29 736 mm 19 7 8 504 mm Door Opening 28 711 mm W x 21 7 8 557 mm H SPECIFICATIONS Form No WFSTm 0612 6 Dimensio...

Страница 7: ...result in damage and injury The National Sanitation Foundation NSF requires that units over 36 914 mm in width or weighing more than 80 lbs 36 kg either be sealed to or raised above the installation...

Страница 8: ...l the reservoir a Lift up the WaTER FILL cup cover and pull forward b Slowly pour water into the cup until the LOW WaTER indicator no longer glows NOTE The capacity of the water reservoir is 3 4 gallo...

Страница 9: ...erior and interior surfaces using a damp non abrasive cloth a non abrasive cleaner may be used for difficult stains Hard to reach areas should be cleaned using a small brush and mild soap 4 Clean the...

Страница 10: ...two motor bearing oil plugs add 6 drops of oil P N 05 01 019 00 and replace plugs 4 Rotate access cover on top of air chamber to oil blower bearing Remove plug add 6 drops of oil and replace Lubricati...

Страница 11: ...Unit is heating but is not producing humidity inside cabinet LOW WaTER indicator is not flashing on display and unit is full of water Contact an authorized Hatco Service agent or Hatco for assistance...

Страница 12: ...Carefully lift the upper WFST unit onto the lower WFST unit and position it inside the stacking brackets Self Closing Sliding Doors Self closing sliding doors are available as a factory installed opt...

Страница 13: ...CTUaL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light...

Страница 14: ...NOTES Form No WFSTm 0612 14...

Страница 15: ...Form No WFSTm 0612 15 NOTES...

Страница 16: ...Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW yORK acme american Repairs Inc Brooklyn 718 456 6544 alpro...

Отзывы: