Model

Voltage

Hertz

Watts

Amps

Plug Configuration

Shipping Weight

LFST-48-1X

120/208

240

60

2150

14.6

NEMA L14-20P

222 lbs. (101 kg)

LFST-48-2X

230 lbs. (104 kg)

SPECIFICATIONS

Plug Configurations

Units are supplied from the factory with an electrical cord and 

plug installed (plugs are supplied according to the application).

WARNING

ELECTRIC SHOCK HAZARD: Plug unit into a properly 

grounded electrical receptacle of the correct voltage, 

size, and plug configuration. If plug and receptacle do not 

match, contact a qualified electrician to determine and 

install the proper voltage and size electrical receptacle.

NEMA L14-20P

Plug Configurations

NOTE: Receptacle not supplied by Hatco. 

Electrical Rating Chart

Model

Width 

(A)

Depth

(B)

Height

(C)

Footprint

Width (D)

Footprint

Depth (E)

LFST-48-1X

48-7/8

 

(1240 mm)

25-3/8

 

(6484 mm)

30

 

(762 mm)

47-3/4

 

(1211 mm)

23-3/8

 

(593 mm)

LFST-48-2X

27-1/8

 

(689 mm)

24-1/4

 

(616 mm)

Cabinet Opening Dimensions: 44

 W x 22

 H (1117 mm x 559 mm)

Dimensions

D

E

Front View

Side View

B

A

C

Front View

Side View

42-1/4″ (1073 mm)

17-1/2″ (445 mm)

21-1/4″

(540 mm)

Rack Dimensions

Содержание FLAV-R-SAVOR LFST-48

Страница 1: ...prendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importante informa...

Страница 2: ...cted for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety...

Страница 3: ...oltage and size electrical receptacle Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning adjustments or maintenance Unit is not weatherproof Locate unit indo...

Страница 4: ...itable for all boxed or wrapped food products The three shelves on the rack have product stops and are inclined toward the service area for excellent product visibility Each shelf can hold three half...

Страница 5: ...rrect voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle NEMA L14 20P Pl...

Страница 6: ...ER INFORMATION section for details 2 Remove tape and protective packaging from all surfaces of unit 3 Install the shelf rack and shelves inside the cabinet a When placing shelf rack inside the cabinet...

Страница 7: ...ds to change the setpoint temperature If no key is pressed within 15 seconds the display will revert to the current temperature of the cabinet 5 Press the key or wait 15 seconds to lock in the new set...

Страница 8: ...e unit as well as maintain performance it is recommended that the unit be cleaned daily NOTICE Use non abrasive cleaners and cloths only Abrasive cleaners and cloths could scratch finish of unit marri...

Страница 9: ...ing Heating elements not working Contact an Authorized Hatco Service Agent or Hatco for assistance Temperature Control not working properly No heat and no lights Power turned off O Move Power I O on o...

Страница 10: ...ARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent...

Страница 11: ...s Distributeurs de Pi ces Couverture Arri re INFORMATIONS IMPORTANTES POUR LE PROPRI TAIRE Notez le num ro de mod le le num ro de s rie la tension et la date d achat de l appareil dans les espaces ci...

Страница 12: ...ement sain AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne s...

Страница 13: ...e chauffage sec qui convient tous les aliments emball s ou empaquet s Les trois tablettes sur le support ont des butoirs de produit et sont inclin es vers la zone de service pour une excellente visibi...

Страница 14: ...configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser un lec tricien qualifi pour d terminer et installer une prise de courant de format et de tension corrects...

Страница 15: ...ection de toutes les surfaces de l appareil 3 Installez le support tablettes et les tablettes l int rieur de l armoire a Lorsque vous placez le support tag res l int rieur de l armoire les tiges au ba...

Страница 16: ...une touche n est enfonc e dans les 15 secondes l affichage revient la temp rature actuelle de l armoire 5 Appuyez sur la touche ou patientez pendant 15 secondes pour verrouiller le nouveau point de co...

Страница 17: ...iffons doux Les chiffons et nettoyant abrasifs pourraient rayer la finition de l unit alt rant son apparence et la rendant vuln rable l accumulation de salet Nettoyez l appareil quotidiennement pour v...

Страница 18: ...onne pas correctement Absence de chaleur et de lumi re Alimentation coup e O Placer l interrupteur de marche arr t sur Marche Le coupe circuit a disjonct R armez le coupe circuit Si le disjoncteur con...

Страница 19: ...VETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairag...

Страница 20: ...314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 9...

Отзывы: