INSTALLATION

Preparing the Installation Site

  1.  Cut the appropriate opening in the countertop for the unit 

being installed. Refer to “Countertop Cutout Dimensions” 

in this section.

  2. If installing the control panel remotely, cut and drill the 

appropriate holes in the vertical surface where the control 

panel will be installed. Refer to the “Installing the Control 

Panel Remotely” procedure for cutout dimensions.

  3.  Make structural modifications or add bracing underneath 

the countertop to ensure the countertop will support the 

weight of the unit and its contents. Make sure a minimum 

2″  (51  mm)  clearance  will  be  available  between  the 

condensing unit and any interior surface.

NOTE: The countertop must be level to ensure proper draining 

of the refrigerated well.

  4.  Cut two openings in the cabinetry to provide proper ventilation 

for the condensing unit. Louvered or grill-style panels should 

be installed in the openings to protect the condensing unit.

 

• Openings should be a minimum of 12″ x 12″ (31 x 31 cm) 

or 144 square inches (961 square cm).

 

• One opening should be located in front of the condenser 

coils with the other opening on the opposite side.

NOTE: Ducting may be required to ensure proper ventilation 

inside the cabinet.

 5. Make sure a grounded electrical receptacle of the 

correct voltage, size, and plug configuration is within 6′ 

 

(1829 mm) of the mounting location for the control panel. 

See the SPECIFICATIONS section for details.

Installing the Unit

NOTICE

Use caution and avoid hitting condensing unit hoses/lines 

when installing unit. Damage caused during installation is 

not covered under warranty.

  1.  Lift the unit out of the shipping frame and carefully lower it 

into the countertop cutout.This step requires two or more 

people, depending on the unit.

  2. Apply National Sanitation Foundation-approved (NSF-

approved) silicone sealant around the edge of the unit to 

seal it to the countertop.

  3.  Install the control panel in the desired location. 
 

• The control panel can be installed on one of three sides 

of the condensing unit support frame. Do not install the 

control panel in front of the condenser coils.

 

• The control panel can be installed remotely within 

48″  (1219  mm)  of  the  condensing  unit.  Refer  to  the 

“Installing the Control Panel Remotely” procedure in this 

section.

  4.  Connect the 1″ drain fitting to a trap and drain line. If a 

trap and drain line are not available, a catch pan (not 

supplied) must be used under the drain fitting to contain 

water draining from the well enclosure.

NOTE: Consult a qualified plumber for proper trap and drain 

installation that conforms to local plumbing codes.

Air Flow

Air Flow

Countertop

Cutout

Ventilation/Control

Access Openings

Air Flow

Air Flow

Installing a CWB-S2 Model

  5. Clean the well enclosure thoroughly in preparation for 

initial operation. Refer to the MAINTENANCE section for 

proper cleaning procedures.

NOTE: If a catch pan is used underneath the drain fitting, make 

sure the pan is emptied regularly to prevent over-flowing.

  6. Rotate the condensing unit, if necessary. Refer to the 

“Rotating the Condensing Unit” in this section.

  7.  Plug the unit into a properly grounded electrical receptacle 

of the correct voltage, size, and plug configuration. See the 

SPECIFICATIONS section for details.

Rotating the Condensing Unit

  1.  Remove the two control panel bolts that secure the control 

panel to the condensing unit support frame. Set aside the 

control panel.

  2.  Place blocks underneath the condensing unit for support 

during rotation.

  3. Remove the 16 support bolts (four on each support) that 

secure the condensing unit vertical supports to the upper 

support brackets on the underside of the well enclosure.

  4.  Rotate the condensing unit 90° or 180°, depending on the 

installation site.

NOTE: Do not rotate the condensing unit in a direction that will 

put the evaporator lines or any other obstruction in front 

of the condenser coil.

  5.  Reattach the vertical supports to the upper support brackets 

on the well enclosure using the 16 support bolts.

  6.  Reattach the control panel to the condensing unit support 

frame using the two control panel bolts.

Содержание CWB-S Series

Страница 1: ...equipo al menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Est...

Страница 2: ...e selected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment This manual provides the installation safety and operati...

Страница 3: ...re all operators have been instructed on the safe and proper use of the unit WARNING This unit is not intended for use by children or persons with reduced physical sensory or mental capabilities Ensur...

Страница 4: ...Corian Swanstone etc Hatco Slim Refrigerated Drop In Wells are designed manufactured and tested to maintain safe food holding temperatures The ecoization logo identifies products designed to reflect H...

Страница 5: ...8 8 9 9 3 9 7 CEE 7 7 Schuko BS 1363 MODEL DESIGNATION SPECIFICATIONS C W B S x Cold Well Built In Slim Full Size Pan Capacity Electrical Rating Chart Plug Configuration Units are supplied from the fa...

Страница 6: ...View Model CWB S4 Side View Model CWB S4 B 2 3 4 70 mm 17 3 8 441 mm 9 1 8 232 mm 15 7 16 392 mm 17 430 mm 2 3 4 70 mm Dimensions Subtract 7 1 2 190 mm from Overall Height C when control box is remote...

Страница 7: ...packaging from the unit 2 Remove tape protective packaging and literature from all surfaces of the unit NOTE To prevent delay in obtaining warranty coverage complete online warranty registration See t...

Страница 8: ...the desired location The control panel can be installed on one of three sides of the condensing unit support frame Do not install the control panel in front of the condenser coils The control panel ca...

Страница 9: ...Refer to the Control Panel Cutout and Screw Hole Dimensions chart for the cutout dimensions 2 Remove the control box from the unit by removing the bolts on the side of the condensing unit 3 Remove th...

Страница 10: ...he digital temperature controller will energize and ON will appear on the display followed by the current temperature of the unit The symbol on the display will illuminate to show the condensing unit...

Страница 11: ...y until the number 22 appears on the display then press the key 4 Use the or key to scroll through the programmable parameters until dI defrost interval appears on the display 5 Press the key to selec...

Страница 12: ...ld detergent Use a plastic scouring pad to remove any hardened food particles or mineral deposits 4 Wipe down well with a clean sanitized cloth to remove the detergent residue Repeat until all deterge...

Страница 13: ...ive noise and vibration when turned on Internal components have not been adequately warmed before operation Turn off unit immediately Unit should be stored in a warm environment of 65 F 18 C for at le...

Страница 14: ...eep Full Pan 6 152 mm Deep Stainless Steel Food Pans Slanted Base Option Slanted bases are options available for all models The slanted base gives the well a 5 tilt NOTE Water will not completely drai...

Страница 15: ...ARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent...

Страница 16: ...le r sultat d une recherche avanc e et d essais pratiques Les mat riaux utilis s ont t s lectionn s pour une durabilit maximale une apparence attractive et des performances optimales Chaque appareil e...

Страница 17: ...erie et en lectricit AVERTISSEMENT Assurez vous que les aliments ont t correctement r frig r s une temp rature appropri e avant de les placer dans l appareil Maintenir des aliments une temp rature ina...

Страница 18: ...bre service est fourni la sortie de l usine avec le nombre ad quat de barres de support de bacs de 305 mm 12 en fonction de la contenance des bacs du mod le Chaque cuve peut accueillir diff rentes com...

Страница 19: ...gr e Slim allong es Contenance du bac grande taille Tableau des valeurs nominales lectriques Configuration des fiches Les appareils sont livr s avec un cordon lectrique avec fiche Diff rentes fiches...

Страница 20: ...RTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se corresponden...

Страница 21: ...t tre orient 90 ou 180 de sa position originale la sortie de l usine Sur les mod les CWB S2 S3 et S4 le groupe compresseur condenseur peut galement tre install dans diff rentes positions entre le cent...

Страница 22: ...voulu Le panneau de contr le peut tre install sur un des trois c t s du cadre de soutien du groupe compresseur condenseur N installez pas le panneau de contr le devant les serpentins du condenseur Le...

Страница 23: ...es de passage de vis et de d coupe pour le panneau de commande pour obtenir les dimensions de d coupe 2 Retirez le bo tier de commande de l unit en retirant les boulons sur le c t du groupe de condens...

Страница 24: ...est activ et refroidit la cuve NOTA Cet appareil est pr r gl la sortie de l usine une temp rature nominale de 32 F 0 C Si les conditions ambiantes n cessitent un r glage de la temp rature nominale rep...

Страница 25: ...cran Pour la premi re mise en service de l appareil ce nombre sera 0 6 Appuyez sur la touche ou dans les 60 secondes pour faire d filer le nombre d heures souhait entre chaque cycle de d givrage Voici...

Страница 26: ...rticule solide de nourriture ou d p t de min raux 4 Essuyez la cuve l aide d un chiffon propre et d sinfect pour enlever toute trace de d tergent R p tez l op ration jusqu ce qu il n y ait plus aucune...

Страница 27: ...s avant la mise en service teignez imm diatement l appareil L appareil doit tre stock dans un environnement chaud une temp rature de 65 F 18 C pendant au moins 10 heures OFF clignote sur l cran de com...

Страница 28: ...64 mm 2 1 2 de profondeu Bac grande taille 102 mm 4 de profondeu Bac grande taille 152 mm 6 de profondeu Bacs alimentaires en acier inoxydable Base inclin e en option Les bases inclin es sont disponib...

Страница 29: ...VETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairag...

Страница 30: ...30 Formulaire n CWBSM 0120 Fran ais Fran ais NOTAS...

Страница 31: ...Form No CWBSM 0120 31 English NOTES English...

Страница 32: ...e Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 753...

Отзывы: