CARE OF TOOL 

Although the Rigidus tool is engineered for durability, it is recommended that the following 
maintenance points are observed, to maximise the life of the tool. 

1.

 

Remove dust, moisture, and other 
contaminants with a clean brush, or 
soft, lint-free cloth. 

2.

 

Do not use any abrasive materials 
that could damage the tool. 

3.

 

All pins, pivot points and bearing 
surfaces should be covered with a 
thin coat of high quality machine oil 
– do not oil excessively.  Light oil 
(such as 30 weight automotive oil) 
used at the oil points shown in the 
diagram, is recommended. 

 

 

4.

 

Wipe excess oil from hand tool, particularly from the crimping area.  Oil transferred onto 
crimp contacts may affect the electrical characteristics of the connector. 

5.

 

When tool is not in use, keep the handles closed to prevent objects from becoming lodged 
in the crimping dies, and store the tool in a clean, dry area. 

 
 
 

ADVICE ON USE 

 

Wear eye protection at all times. 

 
 

Manual tools such as this Rigidus tools are intended for low volume use.  Repetitive, 
high-volume use is not recommended. 

 

The insulated rubber handles are not designed or certified for protection against 
electrical shock. 

 

Use with the Trio-Tek crimp contacts listed on the first page of this instruction sheet. 

This tool is designed for hand use only, and must not be used with clamping, fixturing or use of 
handle extensions. 

 

If you have any questions about this instruction sheet, or the Trio-Tek range of Datamate 
connectors, please contact 

[email protected]

 

Содержание Z80-255

Страница 1: ...AWG wire supplied reeled Harwin recommend the use of BS 3G 210 Type A PTFE Equipment Wire or near equivalent Contact Wire Gauge AWG Typical Stranding no of strands mm Conductor cross sectional area m...

Страница 2: ...losure adjustment function for tool calibration Lifetime tests exceeding 50 000 cycles The contact is correctly crimped when the tool is free to open at the fully closed position i e when the ratchet...

Страница 3: ...ool damage 2 Cut the end of the cable to be terminated so that there is a clean cut end Figure A Strip the cable to the correct length Figure B using a PTFE Wire stripper preferably with adjustable ro...

Страница 4: ...te the crimp by squeezing the tool handles together through the rest of the ratchet clicks another 3 to make 5 in total The handles should then be free to open Remove the crimped wire CRIMP INSPECTION...

Страница 5: ...s open or closed There is a ratchet release lever located inside the movable handle Pressing up on this lever will release the ratchet and the handles should then easily open The jam or miscrimp can t...

Страница 6: ...cator and the dies If you need to replace the die set spare die sets are available from Harwin Please request Part Number Z80 244 Removing the Locator 1 Ensure that the crimp tool is at the fully open...

Страница 7: ...e crimping area Oil transferred onto crimp contacts may affect the electrical characteristics of the connector 5 When tool is not in use keep the handles closed to prevent objects from becoming lodged...

Отзывы: