
Harwin North America
Harwin Europe
Harwin Asia
T: +1 603 893 5376 F: +1 603 893 5396
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
T: +65 6 779 4909 F: +65 6 779 3868
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwin.com.sg
IS-43 Issue: 1 Date: 30.06.2016 C/Note: -----
Page 3 of 4
4.
Make certain that the termination hand tool is in the fully open position, and that the jaws are
free from dirt and debris.
5.
Feed the cable through the slot and securely place the connector within the locating feature
(Female) or flush against the stop washer situated to the right of the tool (Male). See figures 1,
2 & 3.
6.
Once the connector is in the correct position and secure, slowly compress the handle until the connector
is fully shut and the ratchet within the tool has released.
7.
If assembling a second connector to the cable, it is not recommended to feed the wire through the slot.
Instead, assemble the cable into the connector from above. This way, you will be able to terminate the
connector, and still be able to remove the finished assembly from the tool. Please see figures 4 & 5
below as examples.
Figure 2:
Female Connector Position
Figure 3:
Male Connector Position
Figure 5
Figure 1:
Empty Tool Jaws
Ribbon Cable Slot
Stop Washer