4.

 

Make certain that the termination hand tool is in the fully open position, and that the jaws are 
free from dirt and debris.

 

5.

 

Feed the cable through the slot and securely place the connector within the locating feature 
(Female) or flush against the stop washer situated to the right of the tool (Male). See figures 1, 
2 & 3.

 

 

 

 
 

 
 
 

6.

 

Once the connector is in the correct position and secure, slowly compress the handle until the connector 
is fully shut and the ratchet within the tool has released.

 

7.

 

If assembling a second connector to the cable, it is not recommended to feed the wire through the slot. 
Instead, assemble the cable into the connector from above. This way, you will be able to terminate the 
connector, and still be able to remove the finished assembly from the tool. Please see figures 4 & 5 
below as examples.

 

 

 

 

 

Figure 2: 

Female Connector Position 

Figure 3: 

Male Connector Position 

Figure 5 

Figure 1: 

Empty Tool Jaws 

Ribbon Cable Slot 

Stop Washer 