27
Selecting Baler OEM
– MWM-Chute
1. To change the Baler OEM, select the gray cell to the right of
OEM
.
2. When the menu appears, select the correct Baler OEM by scrolling between AGCO, CNH,
John Deere, and Krone.
Set
OEM
to baler model: AGCO, CNH, JD, or
Krone
Set
Bale Width
for baler type
Press
Update ZA
Bale Chamber must be clear to run Zero
Adjust, then press
OK
ZA RANGE
(Zero Adjustment)
Same for Chute or PCC Setup
AGCO
2200 - 3000
CNH
2200 - 3000
John Deere
2200 - 3000
Krone
2200 - 3000
Other
2200 - 3000
If the reading is within range no adjustments need to be made.
**This range is for both 3’ and 4’ (1M & 1.2M) wide balers**
Moisture System Setup
– CHUTE DENSITY – MOISTURE OFFSETTING
Note:
Chute Density setting may be changed after calibration is complete to compensate for various
crop types and allow for minor moisture reading adjustments. Density is based on the dry weight of
the bale. The default setting is 145kg/m
3
.
Lower density settings will result in higher moisture
readings.
Density adjustment range is currently 100-400kg/m
3
.