Wiring Diagram
A. The Baler Power/Communication Harness (006-6650LS(E)) will attach to the open port of the Tractor
Harness (006-6650TM(E)) and run back to the Dual Channel Processor (006-6671LS(E)).
B. Connect the large plug of the Baler Power/Communication Harness (006-6650LS) to the bottom (shorter
side) of the DCP. Attach the Baler Interface Harness (006-6650VA) in between the short whip cable
hardwired to the DCP and the Power/Communication Harness (006-6650LS(E)).
C. Make sure Active Terminator removed from the top of the baler processor is attached to the Baler Interface
Harness (006-6650VA).
D. Attach moisture and bale rate harness (006-7303HL(E)) and also end of bale harness (006-7400BBEXT) to
the DCP (006-6671LS). Model 600BBHD will use harness 006-7303HX.
E. Connect Keyed Power Extension harness (006-5650K) to a keyed power source.
F. Connect the iPad Integration Control (030-6672C) to the Communication Harness (006-6650TM).
G. Note: The Optional Port and the Data Transfer Port are not used in this application.
Keyed Power Extension
006-5650K
Dual Channel
Processor (DCP)
006-6671LS
Moisture/Bale Rate Harness
006-7303HL (600BB)
or
006-7303HX (600BBHD)
Proximity Sensor
006-7303S
Star Wheel Assembly
006-4641 (600BB)
or
006-4641U (600BBHD)
End of Bale Sensor
006-7400
Optional Port
Terminating Connector
006-5650Z
Active Terminator
from Baler Harness
Baler Interface Harness
006-6650VA
iPad Integration Control
030-6672C
Orange Wire to
Keyed Power
Power/Comm Harness on Baler
006-6650LS(E)
Power/Comm Harness on Tractor
006-6650TM(E)
Data
Transfer
Baler
Connection
BB Extension for Bale Sensor
006-7400BBEXT
*Note: (E) indication is used
for International Dealers