NLS110P Pressure Pump

MA1 70-5000

Nanoleader

Pump Series

NLS110P Pressure Pump

User’s Manual

Publication 5422-001-REV-A

Содержание Nanoleader Series

Страница 1: ...NLS110P Pressure Pump MA1 70 5000 Nanoleader Pump Series NLS110P Pressure Pump User s Manual Publication 5422 001 REV A ...

Страница 2: ...ng will be offered for our products which are within the scope of the WEEE Directive Products falling under the scope of the WEEE Directive available for sale after August 13 2005 will be identified with a wheelie bin symbol Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8 medical devices with the exception of implanted or infected pr...

Страница 3: ...s com SUBJECT PAGE NO General Information Warranty and Repairs 2 Specifications 3 Introduction 4 Hardware Overview 5 NLS110P How it Works 6 Operation Getting Started 7 Do s and Don ts 8 Troubleshooting 9 Software Hardware Installation 10 16 Software Hardware Operation 17 20 Table of Contents ...

Страница 4: ...F MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR OF ANY OTHER NATURE Some states do not allow this limitation on an implied war ranty so the above limitation may not apply to you If a defect arises within the two year warranty period promptly contact Harvard Apparatus Inc 84 October Hill Road Holliston Massachusetts 01746 1371 using our toll free number 1 800 272 2775 Goods will not be accepte...

Страница 5: ...lution 0 01 psi Type Dual channel pressure pump Pressure 15 psi to 15 psi Flow Rate Calibrated from experimental data Reservoir Column Variable comes standard with 1cc Serial Port USB Outputs Time ms and psi Power 24Vdc 1 7A 40W Voltage Range Universal Power Supply 100 240 VAC 50 60 Hz Dimensions 24 13 x 17 78 x 10 16 cm 9 5 x 7 0 x 4 0 in Weight 15 91 kg 7 23 lb Specifications ...

Страница 6: ...esults in virtually pulse less flows making experimentation like bubble formation or reproducible flows in multi channels possible This patented pressure monitoring system assures you the highest quality low flow characteristics This pump is an easy to use computer con trolled dual channel non pulsatile pressure pump It has two independent channels of flow with the option of two more independent c...

Страница 7: ...ardapparatus com Introduction To Pressure Sensor Pressure Regulating Pump Heads Reservoir Head and Column Open to Atmosphere FRONT Power Switch Power Input Jack BACK Power Supply Input 100 240 Vac 50 60 HZ Power Supply Input 24 Vdc 1 7A 40W Fan Side Hardware Overview Pump 1 Pump 2 ...

Страница 8: ...IR NLS110P How it Works High Performance Low Flow Pressure Control Flow System Harvard Apparatus NLS110P NLS110P How It Works 1 Pump generates a pressurizing flow of air 2 Pulse of air is compressible and dampened 3 Liquid reservoir is pressurized 4 Pressure sensor maintains a pulse free flow based on pressure set ...

Страница 9: ...cord and power supply attach the instrument to 110 VAC or 220 VAC Tubing Connections Install tubing as shown in Figure 1 Leave one side open and attach the output port to the provided liquid reservoir or to the input of the system to be controlled What s Included The pump comes standard with 10 feet of 1 16 OD tubing 10 feet of 1 32 OD tubing fittings and ferrules ...

Страница 10: ...rning off power to the pump or unplugging the USB cable DON T Allow liquid to enter the pressure sensor This will permanently damage it DON T Turn on off any power while the air reservoir is sealed Always leave it open to air as the pump may spike and overload the sensor DON T Attempt to apply or measure any pressures outside of 15psi DON T Seal the other side of the peristaltic pump tubing If the...

Страница 11: ...et to a non zero target pressure There is a leak in the air pressure chamber Tighten your connectors and or tighten the clamp arm of the peristaltic pump PROBLEM The MEASURED output is abnormal even when all tubes are disconnected It is likely that liquid has entered the sensor and damaged it There may be something else seriously wrong with the circuit board ...

Страница 12: ...nt should show on the display or you can run it manually by click ing on my computer then navigate the CD drive usually drive D 3 Run the application from the CD or copy the content to your PC 4 Double Click to open the folder and then open NLS110P Customer Installation Builds Build My Installer Volume Run Setup exe 5 The following screen will appear 6 Select destination directory then click next ...

Страница 13: ...11 H a r v a r d A p p a r a t u s N L S 1 1 0 P P r e s s u r e P u m p www harvardapparatus com Hardware Software Installation Cont 7 Choose accept then click next 8 Choose accept then click next ...

Страница 14: ...t u s N L S 1 1 0 P P r e s s u r e P u m p Publication 5422 001 REV A Hardware Software Installation Cont 9 Start Installation by clicking next 10 All necessary files will be installed 11 Wait for the installer to finish building ...

Страница 15: ... a t u s N L S 1 1 0 P P r e s s u r e P u m p www harvardapparatus com Hardware Software Installation Cont 12 After the installer has finished building click finish 13 After installing it will ask you to restart the PC restart ...

Страница 16: ...le as follows mini B terminal to the back of the pump and the A terminal to the USB terminal on the PC 16 Connect the power adaptor to the DC input jack on the back of the pump 17 Turn on the power switch on the back of the pump 18 The PC should recognize that there is a new hardware installed 19 Select yes this time only then click next 20 Select install from a list or a specific location then cl...

Страница 17: ...a r a t u s N L S 1 1 0 P P r e s s u r e P u m p www harvardapparatus com Hardware Software Installation Cont 21 Browse to the main folder that was copied from the CD or browse the CD then click next 22 Click continue anyway ...

Страница 18: ...hrough the CD 26 Click on Application exe 27 The application window should appear 28 On the application exe click on the dropdown box of port1 required 29 You should see a list of com ports two of these com ports should have consecutive numbers 30 Select the lower numbered com port between the two consecutive ports 31 Click on the dropdown box of port2 optional 32 Select the higher numbered com po...

Страница 19: ... of the screen underneath Edit 2 The graph on the right should show lines on the 0 amplitude after a few seconds 17 H a r v a r d A p p a r a t u s N L S 1 1 0 P P r e s s u r e P u m p www harvardapparatus com Software Hardware Operation ...

Страница 20: ...re for each channel 5 Calibration for each pump head choose the appropriate calibration ex Calibration 1 tab and enter in the calibration values provided The calibration values can be found on the back of the pump directly behind the corresponding pump head Each pump head may be recalibrated with the use of a manometer by following the Calibration Instructions document on the CD See label on rear ...

Страница 21: ...w harvardapparatus com Software Hardware Operation Cont 6 Script Files Under the Script tab you can choose to read a script file select a destination for the output text file and set a sampling rate An example of a script file and its corresponding output is provided on the CD ...

Страница 22: ...s designed to give you an approximation of your current flow rate By entering in the inner diameter of your tubing the length of your tubing and the viscosity of your fluid the resistance calculator will calculate your resistance Then after selecting what is at each end of your tubing you can enter in the resistance cal culated into the Hydraulic Resistance field This will calculate your approxima...