![HARTMANN ELECTRONIC BUS908 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hartmann-electronic/bus908/bus908_hardware-user-manual_601823011.webp)
Hartmann Electronic GmbH
Backplanes
Motorstraße 43
Aufbausysteme (MPS)
Tel.: +49 711 1 39 89-0
Layoutservice
Fax: +49 711 8 66 11 91
[email protected]
www.hartmann-electronic.com
Geschäftsführer:
Registergericht Stgt. HRB 7630
Deutsche Bank AG, Singen
Werner Fritz
USt.-Id.-Nr. DE 147816208
BLZ 692 700 38 - Kto.-Nr. 050 1403 00
Dr. Günter Zahnenbenz
Steuer-Nr. 9908300985
Swift-Code DEUTDE6F692
11
3. Initial Set-Up
3.1 Installing the board into a CPCI system
1) Power down your host system and your external CPCI System.
2) Insert the CPCI Board into the System Slot of your CPCI system. Make sure that the latch of the CPCI board is
closed.
3) Connect your host system through a PCIe X1 Cable to the upstream port of the CPCI board.
4) Tighten the screws of the X1 Cable at the host (or host adapter) and the board.
5.) Before applying power to your external CPCI system make sure that all other CPCI
Boards are installed correctly in your system. You may follow the instruction of your
CPCI board supplier to install the board mechanically.
6) Power up your external CPCI system.
7) Power up your host system.
8) Your CPCI system should be enumerated automatically.
3.2 Installing a third party PCIe device at the PCIe X1 Downstream Port
1) Power down your host system and your second and third party CPCI system.
Second party system
:
System that is connected directly to the host system.
Third party system
:
System that is connected to the host through the second party system.
2) Insert the CPCI Board into the system slot of your second party CPCI system.
Make sure that the latch of the CPCI board is closed.
3) Connect your host system through a PCIe X1 Cable to the upstream port of the board that is plugged into your
second party system.
4) Tighten the screws of the PCIe X1 Cable at the host (or host adapter) and the board of the second party
system.
5) Insert the CPCI Board into the system slot of your third party CPCI system.
Make sure that the latch of the CPCI board is closed.
6) Connect the downstream port of the second party system board with the upstream port of the third party
system board via a PCIe X1 Cable.
7) Tighten the screws of the X1 Cable on both boards (second party board and third party board).
8) Power up your third party CPCI system
9) Power up your second party CPCI system
10) Power up your host system
11) Both of your CPCI systems should be enumerated automatically
Note:
The system that is at the lowest level of the hierarchical PCIe structure should
be powered up first.