background image

VCI10-AH ANDROID

TM

 HART

®

 COMMUNICATION INTERFACE                                         INSTALATION, OPERATION AND CONFIGURATION MANUAL 

______________________________________________________________________________________________________________________________ 

 

 

16 

 

 VMT-HART 

 

 

VMT-HART

 (

Vivace Mobile Tool HART

) is a versatile configurator for HART

®

 devices on 

Android

™ 

plattform which integrates 

Vivace Process Instruments 

application family. 

 

Working  with  VCI10-AH  interface,  it  provides  a  complete  solution  for  accessing  and  managing 

HART

®

 field devices. It allows configuration, calibration, maintenance and monitoring variables from  any 

HART

®

 device. 

VMT-HART  uses  information  described  on  device  DDL  file  (

Device  Description  Language

)  to 

determine the content to be shown on each screen, which variables can be edited, which procedures must 
be followed for execute calibration, setup or maintenance. 

Before using VMT-HART, check if the configured interface is the VCI10-AH (USB). 

“Interface” option 

will be found on pop-up menu of VMT-HART initial screen. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 8.1 

– VMT-HART: communication interface.   

 

 

Figure 8.2 

– License.

 

 

 

After that, it will be necessary to activate VMT-HART license. Enter option 

“License” on 

pop-up

 menu 

of  VMT-HART  initial  screen  (Figure  8.2)  and  send    to 

Vivace  Process  Instruments

  via  e-mail 

(contato

@vivaceinstruments.com.br) “Code 1” and “Code 2” in order to receive the register key.  

After receiving the register key, access license screen, type the key on 

“Enter New Code” field and 

click on the button 

“Activate”.   

VMT-HART will be ready to communicate with VCI10-AH after this registration. Check if the interface 

is powered and configured correctly. 

 
For more details about VMT-HART app, please consult application manual, available for download 

on 

www.vivaceinstruments.com.br

 

 

 

 

Содержание Vivace VCI10-AH

Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL June 2016 VCI10 AH ANDROIDTM HART COMMUNICATION INTERFACE...

Страница 2: ...tain compliance with the hardware and software versions described herein However due to the dynamic development and version upgrades the possibility of technical deviations cannot be ruled out We cann...

Страница 3: ...________________________________________________________________________________ 3 SUMMARY 1 EQUIPMENT DESCRIPTION 6 2 PRODUCT CONTENT 10 3 CONNECTION 11 4 BATTERY 12 5 LABEL 13 6 TECHNICAL SPECIFICAT...

Страница 4: ...practice relating to installation ensuring correct grounding noise insulation and good quality cables and connections in order to provide the best performance and durability to the equipment Special a...

Страница 5: ...ined in its manual as well as technical characteristics not guaranteeing its full performance in particular applications The operator of this equipment is responsible for observing all aspects of safe...

Страница 6: ...d devices such as smartphones and tablets via USB communication The interface works with version 5 6 or 7 of HART protocol using VMT HART app to configure monitor and calibrate HART devices in real ti...

Страница 7: ...ION MANUAL ______________________________________________________________________________________________________________________________ 10 2 PRODUCT CONTENT Check if all the following items are cont...

Страница 8: ...own on Figure 3 1 Figure 3 1 VCI10 AH connection The interface physical connection is resumed to only one step Insert the VCI10 HA interface on the micro USB port and plug the clips on the HART bus VC...

Страница 9: ...not be enabled when device is connected to HART 4 20 mA bus only in bench work or disconnected from bus Check Pwr switch when it is positioned to On interface will provide power to device according t...

Страница 10: ...___________________________________________________________________________________________________________________ 13 5 LABEL VCI10 AH has an identification label fixed on its frontal side See on tab...

Страница 11: ..._________________________ 14 6 TECHNICAL SPECIFICATION The main technical and physical characteristics of VCI10 AH are listed on Table 6 1 Those are important references which must be analysed before...

Страница 12: ...INTERFACE INSTALATION OPERATION AND CONFIGURATION MANUAL ______________________________________________________________________________________________________________________________ 15 7 HOUSING DIM...

Страница 13: ...e edited which procedures must be followed for execute calibration setup or maintenance Before using VMT HART check if the configured interface is the VCI10 AH USB Interface option will be found on po...

Страница 14: ...ART COMMUNICATION INTERFACE INSTALATION OPERATION AND CONFIGURATION MANUAL _____________________________________________________________________________________________________________________________...

Страница 15: ...lacing spare parts but it is strongly recommended to forward it to Vivace for diagnosis and maintenance in cases of doubt or impossibility of correction by the user For details about the product warra...

Страница 16: ...ice n COMMERCIAL CONTACT Complete Name Position Phone and Extension Fax e mail TECHNICAL CONTACT Complete Name Position Phone and Extension Fax e mail EQUIPMENT DATA Model Serial Num PROCESS INFORMATI...

Страница 17: ...ROIDTM HART COMMUNICATION INTERFACE INSTALATION OPERATION AND CONFIGURATION MANUAL _____________________________________________________________________________________________________________________...

Отзывы: