background image

RUG-045/046/055

Heavy Duty Steel Rugby Posts

INS617

Revision 2

09/09/2015

Harrod UK Limited

©

Heavy Duty Steel Rugby Posts

RUG-055 Hinge assembly only

1. 4 x FEP281

Hinge Assembly

1. 4 x FEP281

Hinge Assembly

(RUG-046)

2. 4 x FEQ715

Bottom Upright

2. 4 x FEQ678

Bottom Upright

3. 2 x FEQ650

Crossbars

4. 4 x PEQ685

Ground Socket

(RUG-045)
(RUG-046)

Tools Required

1 x 22mm spanners
2 x 19mm Spanners
1 x Spirit Level
1 x Tape Measure
2 x Step Ladders

IMPORTANT

PLEASE READ THE ASSEMBLY

I N S T R U C T I O N S C A R E F U L LY B E F O R E
STARTING TO ASSEMBLE YOUR POSTS.

IMPORTANT

Assembly of these posts

should not take place in windy conditions.

For safety reasons; Post Protectors must be
used with all Hinged Rugby Posts to cover the
hinge arrangement.

Safety Notes

1
2

4

A risk assessment must be carried out on the
erection of Hinged Rugby and Rugby Adaptors.

Always use mechanical assistance if the Risk
Assessment highlights this requirement.

Always check fasteners before use and tighten
where necessary.

Periodically apply grease to hinge fixing bolts to
pre-long the life the posts.

These posts should always be taken down in
windy conditions.

3

5

Important Note for RUG-055

If RUG-055 has been purchased for adapting
an existing set of rugby posts, you will need to
cut down your existing uprights as follows:
For sockets installed 25mm below ground
level the distance from the underside of the
channel to the bottom of the upright needs to
be 2909mm. For sockets flush with ground
level this needs to be 2884mm.

4

1

3

Fig 1

914

914

914

2

Important note for about Crossbars

The Crossbar (FEQ650) is a universal
component that is used on other products. It
contains instruction number INS618. Please
ignore INS618 and use these instructions
(INS617) to install and assemble your posts.

Code:

Product:

Pack Contents:

View of Product

Отзывы: