WARNING: Disconnect primary power prior to servicing.
Section I Operator Guide
Z3-48HD+
1.4
Alignments
NOTE:
All adjustments required have been made at the factory using calibrated test loads
and power meters to verify operating power levels. The following alignments are
to be performed only in the event of a field replacement involving any of these
components.
Three RF to DC sample transducers, in conjunction with RF directional couplers, are
used in each system, ZD32 and Z3-48, to monitor the RF power levels in that system.
The DC samples are routed through coaxial cables to the input jacks on the back of the
System Controllers.
The linearizer test point voltages are initially set using the tables below as determined
by the type of system with adjustments made using the corresponding sample
calibration pot (R37, R45 or R78). Variation of these voltages will exist depending on
desired high power output and linearity of circuit.
Table 1-3 ZD32 System Controller: FM+HD Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
14kW of system forward power
R37
TP3
0.075 Volts
560 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 3.5kW
R78
Table 1-4 ZD32 System Controller: HD Only Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
7kW of system forward power
R37
TP3
0.075 Volts
280 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 1.75kW
R78
Содержание Z3-48HD+
Страница 4: ...MRH 2 888 2621 001 12 5 07 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...12 5 07 888 2621 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 7: ...12 5 07 888 2621 001 vii WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 5 07 888 2621 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 12: ...2 888 2508 001 WARNING Disconnect primary power prior to servicing Table of Contents ...