VCA/VDA/VEA6800
+
Installation and Operation Manual
19
Chapter 2: Installation and Configuration
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Setting the Clamping Mode
Follow this procedure to set the jumper for soft-, hard- or no-clamping
mode:
1. Locate the jumper block on the module.
shows the location of this jumper block.
2. Place the jumper on the pin that corresponds to soft-, hard- or
no-clamping mode. See
Figure 2-4.
VCA6800
+
Clamping Mode Jumper Block Pin
Placement
Adjusting Potentiometers
The VCA6800
+
module has two separate, adjustable potentiometers
(“pots”) for gain and EQ mode adjustment.
shows the location of these pots.
A multi-turn pot allows you to adjust gain for a range of –3 dB to +3
dB. See
•
To increase the gain, turn the pot clockwise.
•
To decrease the gain, turn the pot counterclockwise.
A second multi-turn EQ pot allows you to adjust cable equalization. See
.
•
To obtain more equalization, turn the pot clockwise.
•
For less equalization, turn the pot counterclockwise.
Soft clamp
Hard clamp
No clamp
No clamp
mode
Hard clamp
mode
Soft clamp
Hard clamp
No clamp
Soft clamp
mode
Soft clamp
Hard clamp
No clamp