9/15/06
888-2586-001
2-25
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation & Initial Turn-On
Platinum Z16HD+
2.6
Initial Turn-on
!
CAUTION:
ANY REMOTE OR EXTENDED CONTROL CONNECTIONS SHOULD BE
CONNECTED ONLY AFTER THE TRANSMITTER SYSTEM IS CHECKED OUT
AND FULLY OPERATIONAL.
Each transmitter is thoroughly checked out during factory final test but adjustment may
be required during installation due to shipping, variations in primary power, antenna
systems, or transmission line differences. Any remote or extended control connections
should be connected only after the transmitter is checked out and fully operational.
Refer to the Factory Test Data Sheets supplied with the transmitter for typical meter
readings. The transmitter was checked into a 50-ohm resistive load at the Factory.
The Transmitter ON-OFF sequence is controlled by three separate buttons:
•
HIGH
•
LOW
•
OFF
These buttons are located on the front panel of the Controller.
STEP 1
Activate the STATION AC POWER source to the transmitter.
STEP 2
Turn on the low voltage power supply breaker, CB1, located in the rear
of the transmitter cabinet in the upper right-hand corner. Close and
secure the rear door.
STEP 3
Verify that the two LCD displays on the front of the controller are active.
The Diagnostics display should look like Figure 2-8. The Fault LED on
the front panel will be lit, since the modules are not installed yet, and
should be ignored at this point.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...