2-26
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
Figure 2-8 Z16HD+ Default Diagnostics Display
STEP 4
Press the PA VOLTS button on the front panel of the controller.
STEP 5
Press the LOW power ON button on the front of the controller, but be
ready to quickly press the off button if necessary. The PA VOLTS
reading on the front panel should be above 40Vdc and the blower should
come on at HIGH speed.
NOTE:
If the blower does not run, check the position of wires #1, #2 and #3 for 3-phase
or wires #1 and #2 for a single phase, at A17TB1 (1A17TB1 on the single phase
transmitter). If these are connected in the wrong position, the fan may not operate
(this is also true for the single phase transmitter due to switching on the Low
Voltage Supply Board). Also check blower fuses F1 and F2 located in the bottom
deck of the front PA compartment.
STEP 6
If the PA VOLTS reading appears okay then shut the transmitter off and
insert the PA and IPA Modules as directed below. See Figure 2-9 and
Figure 2-10.
STEP 7
PA Module installation - Eight PA modules and 2 IPA modules are
inserted in the front of the cabinet and eight in the back of the cabinet.
The PA and IPA modules are identical and symmetrical which means
they can be inserted with either side of the module facing up and cannot
be inserted improperly. The modules should only require a minimal
amount of force for insertion into the card edge connectors. If they do
not slide in easily, check the connectors on the combiner boards, and
visually inspect the combiner assembly to verify nothing has come loose
and/or moved during shipment.
NOTE:
The Factory Test Data Sheet contains the serial numbers of each of the PA and
IPA modules. The data sheet also tells which slot each of the PA modules were
connected into during factory testing. While it is Not Critical to operation, the
transmitter readings may be closer to the data sheet if the PA and IPA modules are
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...