Table 6-4 Power Supply Controller Related Faults
FAULT
COMMENT
ACTION
PSC# +20V
+20V DC supply to PSC failed
Shut Power Supply OFF and discharge.
PS#_DSCHG
A failure of the discharge circuit has been
detected
Transmitter is shut off
PS#_START
Supply voltage did not reach 40V during
Soft Start. Could be an SCR problem or
open soft start/discharge resistor (Mounted
on top of each transformer).
Shut Power Supply OFF and discharge.
PS#_HS_TEMP
Rectifier heat sink temperature overload
(>100
o
C)
Shut Power Supply OFF and discharge
PS#_PHS_LS
Transformer primary phase loss or severe
imbalance
Mute for 20 seconds and try to turn on again.
Repeats until successful.
PS#_CONFIG
Power supply #n has a cable configuration
fault
Mute
PS#_JUMP
Upper or lower tap not available once
current tap failed
Shut Power Supply OFF and discharge
PS#_TAP1
Tap 1 failed. One or more of the secondary
SCRs for the 48V tap have failed on the
designated Power Supply.
Tap1 fault indication. PSC will automatically
switch to Tap2 if it is not faulted. If Tap2 is
faulted off, shut Tx off with PS#_JUMP fault.
PS#_TAP2
Tap 2 failed. One or more of the secondary
SCRs for the 50V tap have failed on the
designated Power Supply.
Tap2 fault indication. PSC will automatically
switch to Tap1 if it is not faulted. If Tap1 is
faulted off, switch to Tap3. If Tap3 is faulted
off, shut Tx off with PS#_JUMP fault.
PS#_TAP3
Tap 3 failed. One or more of the secondary
SCRs for the 52V tap have failed on the
designated Power Supply.
Tap3 fault indication. PSC will automatically
switch to Tap2 if it is not faulted. If Tap2 is
faulted off, switch to Tap4. If Tap4 is faulted
off, shut Tx off with PS#_JUMP fault.
PS#_TAP4
Tap 4 failed. One or more of the secondary
SCRs for the 54V tap have failed on the
designated Power Supply.
Tap4 fault indication. PSC will automatically
switch to Tap3 if it is not faulted. If Tap3 is
faulted off, shut Tx off with PS#_JUMP fault.
PS#_COMM
PS Controller not able to communicate with
the Master
Fault indication. No transmitter action taken.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...