6-8
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 6 Troubleshooting
6.8
BoostPro Faults
The BoostPro front panel LED will illuminate red if a fault condition is detected. Press
INFO, then FAULT SUBMENU to view a listing of statuses where the malfunction
would be indicated by the word FAULT.
To reset the fault, press INFO, then CONTROL SUBMENU, move cursor to point to
RESET FAULT. Press ENTER to clear the fault status. If the fault indication is still
present, the condition causing the malfuntion will need to be identified and corrected.
6.8.0.1
3-Strike Faults
To prevent temporary fluctuations in power, temperature, current, or voltage from
causing nuisance fault-off conditions, a 3-strike routine is programmed into the sensing
circuits. If any of the following faults are indicated, it is because 3 separate momentary
fault conditions over a specified period of time, or a continuous fault condition over a
specified time has occured.
VSWR TRIP: Reflected power overload, based on the TX type and modulation
defined in the master configuration file.
FWD PWR TRIP: Forward power overload, based on the TX type and modulation
defined in the master configuration file.
PA TEMP: 90°C threshold exceeded - Fault off.
PA CURR: 6.4A threshold exceeded - Fault off.
PA OVER V: 28.8V (120% Nominal voltage) Threshold exceeded - Fault off.
PA UNDER V: 19.2V (80% Nominal voltage) Threshold exceeded - Fault off.
6.8.0.2
Other Faults
FAN TACH: FAN tachometer indicates a low speed, or no operation fan condition -
Fault off.
APC UNLOCK: The difference between the power sense and the ALC reference is
greater than 50 counts, lasting for more than 2 - 5 seconds - Fault off.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...