A short-duration surge, due to transformer inrush current, will
occur at turn-on or during a short AC power loss. This surge can
be as high as 400 amps. During this surge, the line voltage at the
cabinet must not drop below 80% of the rated line voltage. Select
a 40 amp breaker or fuse for the transmitter using the above
inrush current information.
2.3.3
AC mains Disconnect Location
The circuit breaker panel should be located near the transmitter
in a well lighted area. As a safety precaution, controls for
disconnecting the main power service supplying the transmitter
must be convenient to the operator and maintenance personnel.
Breakers must be clearly labeled. Provisions for emergency
lighting should be made.
2.4
Unloading and Unpacking
2.4.1
Equipment Required for Unloading
Examine the weights listed on the Transmitter Outline drawing
for guidance on the equipment needed. Note: The notch
diplexer, if used, will be the heaviest.
2.4.2
Unpacking, Equipment Inventory and Inspection
A “check-off” box is available to help the installer track the steps
that have been completed.
When the transmitter is delivered to the site, the shipment should
be inspected and inventoried before installation is begun. This
section provides information to assist unpacking and inventory.
Locate the packing check list when the shipment arrives.
Each transmitter shipment will be accompanied by a packing
check list identifying which equipment is packed in the various
crates and boxes.
LOCATED PACKING CHECK LIST
The contents of the shipment should be inventoried with the
packing list. Carefully unpack the unit and perform a visual
inspection to determine if any apparent damage has been in-
curred during shipment. Retain all shipping materials until it has
been determined that all items on the list are on site and no
damage occurred during shipment. It may be necessary to search
packing material for parts initially missed during unpacking.
The carrier may also wish to examine the packing material.
If the contents are incomplete, or if the unit is damaged electri-
cally or mechanically, notify the Harris Customer Service De-
partment by phone at 217-222-8200, FAX at 217-222-9443 or
at the following address:
Harris Corporation,
Broadcast Division
P.O. Box 4290
Quincy, Il 62305
Attn. Customer Service Department
INVENTORY OF EQUIPMENT COMPLETED
The equipment becomes the property of the customer when the
unit is delivered to the carrier. Claims for damaged equipment
Vestigial Sideband Demodulator Tektronix 1450/1350 or
Equivalent
Option 1 37 MHz IF, NTSC CCIR-M (USA and others)
Option 2 38.9 MHz IF, CCIR-G, PAL
Tektronix Sideband Analyzer
Consisting of:
1405 Sideband Adaptor
2710, 490, or 2750 Spectrum Analyzer
Tektronix 1910 Signal Generator or equivalent
Tektronix 1780 Video Measurement Set
Aural Stereo Generator, Orban 8182A or equivalent
Aural Demodulator Tektronix 751, TFT-850, or equivalent for
stereo
Time & Frequency Technology 701, 702, or equivalent for
monaural
A method of measuring transmitter frequency with two
sources. (Frequency Counter,
Frequency Counter on De-
modulator, Outside Frequency Measuring Service.)
Audio Oscillator and Distortion Analyzer (Sound Technology
1710A or equivalent).
Asaca 201-1 Envelope Delay Measuring Set
Scope Camera
RF Bridge, Ealge RLB-150, or precision directional coupler
700-1289-000
UHF RF Notch Filter, Eagle Model TNF-1 484-0300-000
Various RF Adaptors and Connectors
3-1/8 inch to type “N” adapter - 620-0008-000
Type N to BNC male to female - 620-0128-000
Type N to BNC female to male - 620-0547-000
Type BNC plug to Subminiax Plug
Type BNC plug to Subminiax Jack
Type BNC barrel - 620-0604-000
Type BNC to SMB (push-on) - 620-0628-000
TNC-BNC - 620-2821-000
Bird Model 43 Wattmeter with elements from 1W to 1000W
Adaptor 1 5/8" coax to N connector
Manometer Dwyer model 40-1 (range 0.1-0-1.0"WC) or equal
Tee kit Dwyer A-604T or equal
Fluke Multimeter and Style C Current Probe
Table 2-1. Recommended Test Equipment
Platinum™ Series
2-2
888-2457-001
WARNING: Disconnect primary power prior to servicing.
Содержание Platinum HT EL 2000HS
Страница 4: ...This page left blank intentionally ...
Страница 6: ......
Страница 8: ...ii ...
Страница 12: ...This page left blank intentionally ...
Страница 26: ...Figure 2 3 Platinum Series 2 8 888 2457 001 WARNING Disconnect primary power prior to servicing ...
Страница 27: ...Figure 2 4 Section II Installation 888 2457 001 2 9 WARNING Disconnect primary power prior to servicing ...
Страница 28: ...Figure 2 5 Platinum Series 2 10 888 2457 001 WARNING Disconnect primary power prior to servicing ...
Страница 29: ...Figure 2 6 Section II Installation 888 2457 001 2 11 WARNING Disconnect primary power prior to servicing ...
Страница 30: ...Figure 2 7 Platinum Series 2 12 888 2457 001 WARNING Disconnect primary power prior to servicing ...
Страница 31: ...Figure 2 8 Section II Installation 888 2457 001 2 13 WARNING Disconnect primary power prior to servicing ...
Страница 32: ...Figure 2 9 Platinum Series 2 14 888 2457 001 WARNING Disconnect primary power prior to servicing ...
Страница 33: ...Figure 2 10 Section II Installation 888 2457 001 2 15 WARNING Disconnect primary power prior to servicing ...
Страница 34: ...Figure 2 11 Platinum Series 2 16 888 2457 001 WARNING Disconnect primary power prior to servicing ...
Страница 38: ...This page left blank intentionally ...
Страница 46: ...This page left blank intentionally ...
Страница 54: ...This page left blank intentionally ...
Страница 88: ...This page left blank intentionally ...