42
HMX6803
+
and OP
+
HMX
+
Installation and Operation Manual
Copyright © 2009, Harris Corporation
Chapter 3: Operation
Changing Parameter Settings
You can change parameter settings at the card edge. You can change the
parameter settings, view read-only parameters, view alarms, and adjust alarm
settings using CCS software. See the following topics:
•
“Changing Parameter Settings Using Card-Edge Controls” on page 42
•
“Changing Parameter Settings Using CCS Software” on page 43
Changing Parameter Settings Using Card-Edge Controls
1. Rotate the hex switch (mode select rotary switch) to
0
.
2. Once the hex switch is set to “0,” toggle the navigation switch up or down
to select a bank.
View the two control LEDs next to the navigation toggle switch to see
which bank is currently selected. (See
See
to view the various banks, hex switch positions,
and corresponding parameter options and values.
3. Rotate the hex switch to the parameter number (1 to 9) or letter (A to F) of
the option you want to set.
4. Toggle the navigation switch to select and set the value of the chosen
parameter.
5. Do either of the following:
Table 3-9. Selected Bank as Indicated by Control LEDs
Bank Number
LED 3
LED 2
LED 1
LED 0
0
Off
Off
Off
Off
1
Off
Off
Off
On
2
Off
Off
On
Off
3
Off
Off
On
On
4
Off
On
Off
Off
5
Off
On
Off
On
6
Off
On
On
Off
7
Off
On
On
On
8
On
Off
Off
Off
9
On
Off
Off
On
A (10)
On
Off
On
Off
B (11)
On
Off
On
On
C (12)
On
On
Off
Off
D (13)
On
On
Off
On
E (14)
On
On
On
Off
F (15)
On
On
On
On