14
HMX6801
+
B2/C2 and HMX6801
+
B4/C4 Installation and Operation Manual
Chapter 2: Installation
Setting Jumpers
The HMX6801
+
B2/C2 and HMX6801
+
B4/C4 modules have one
jumper for remote or local control.
shows the location of the
REM/LOC
jumper.
Figure 2-1.
Location of the REM/LOC Jumper (B4/C4 is shown)
Follow this procedure to set the
REM/LOC
jumper for either remote or
local control:
1. Locate the
REM/LOC
control jumper on the module (beside the
extractor handle).
shows the standard location of the
REM/LOC
jumper.
2. Place a jumper on pins 1 and 2 to set the module for Remote control
or pins 2 and 3 to set the module for Local control. See
Figure 2-2. REM/LOC
Settings for Remote and Local Control
Table 1-1 "Generic 6800+ Module Features"
on local/remote control jumper functionality.
REM/LOC jumper
Remote/local
Note
You must configure modules for
local or remote operation
prior
to power-up. To change the
configuration, first remove
power from the module, reset
the jumper, and then reapply
power.
The white triangle near the
jumper pins on the module
indicates pin 1.
1 2 3
1 2 3
Remote control setting
Local control setting