WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 4 RF Testing
4.4
Appendix B - Generating a CW Tone
a.
Open a web browser and enter the IP address of the eCDi with the target exciter
port.
1.
http://eCDI's IP:20080 exciter AAdd: Steps 1, 2 & 3.
2.
http://eCDI's IP:20180 exciter B
3.
(API Test Configuration Register 1)
4.
"Request Memory File"
5.
Memory Start Address: 40000C8
6.
Memory Length: 1
7.
This will be used to verify the current value.
8.
Go to "Upload/Execute FPGA Script File" and upload the script file
"CWEnable.txt"
9.
Script "CWDisable.txt” will disable the tone once testing is completed.
b.
CW enable script
1.
n
2.
# Script file for testing FPGA Modulator board
3.
# m <address> <count> <cr>- dump data command; dumps "count" 32-bit
words at <address>
4.
# l <address> <count> <data> <cr>- fill same data command; fills "count"
32-bit words with data starting at <address>
5.
# p <address> <count> <d(n) d(n+1)... d(count)> <cr> - fill data
command; fills "count" 32-bit words data(n) to data(count) starting at
<address>
6.
# k <address> <cr>- peek address command; reads 32-bit data word at
<address>
7.
# o <address> <data> <cr>- poke data command; writes 32-bit data word
at <address>
8.
# h <cr>- echo on command - enables echo of command file to log file
9.
# n <cr>- echo off command - disables echo of command file to log file
10.
# w <cr>- wait for 10 msec.
11.
# z - END FILE: z
12.
h
13.
# enable cw tone IQ_MUX_ATT
c.
CW disable script
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...