APEX
™
Exciter Incorporating FLO
™
Technology
Navigating the LCD Display Screens
Details of the Exciter Status Screens
Page: 3-16
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
3.4.4.5
FLO FPGA, Transport Stream Status, Screen 3/5
FPGA Status3.bmp
Figure 3-14 FLO FPGA, Transport Stream Status Screen 3/5
The parameters of the Transport Stream Status screen are as follows.
•
TS1 Detect:
Yes or No
TS2 Detect:
Yes or No
Yes = transport stream present, No (in red) = transport stream missing
•
TS1 LOF:
Yes or No
TS2 LOF:
Yes or No
Yes (in red) = fault, No = TSI LOF is OK
•
TS1 OOF:
Yes or No
TS2 OOF:
Yes or No
Yes (in red) = fault, No = TSI OOF is OK
•
TS1 OOF Ct:
Integer Decimal
TS2 OOF Ct:
Integer Decimal
•
TS1 Pkt Rt:
Integer Decimal
TS2 Pkt Rt:
Integer Decimal
•
WPID Pkt Rt:
Decimal
SSF Missing:
Yes or No
Yes (in red) = SSF missing, No = SSF OK
•
LPID Pkt Rt:
Decimal
SSF Multiple:
Yes or No
Yes (in red) = SSF multiple, No = SSF OK