ACO6800
+
Installation and Operation Manual
59
Copyright © 2009, Harris Corporation
Chapter 6: IDSD Parameters, LEDs, and Alarms
Group A Switch Low
Priority
1, C
Sets the low priority for switching
• GPI Input
• Manual
•
Alarms
Group A Alarm Switch
Level
1, D
Sets the level for alarm auto switch
1 to 10 (
6
)
Group A Manual Switch 1, E
Sets what the output source will be when
a channel is switched manually
•
Disable
• Switch to A1
• Switch to A2
Group A Relay Bypass
1, 1
Activates the relay bypass
• On
•
Off
Group A Relay Status
[RO]
Displays whether or not the relay is
active
• On
• Off
ACO Group A > General Purpose Interface
Group A GPI In Trigger
Level
1, 2
Sets the level at which an alarm is
triggered for the Group A GPI Input
•
Active Low
• Active High
Group A GPI Out
Trigger Level
1, 3
Sets the level at which an alarm is
triggered for the Group A GPI Output
• Active Low
•
Active High
Group A GPI Input_1
[RO]
Displays whether or not GPI Input_1 has
been switched to A1
• N/A
• Switch to A1
Group A GPI Input_2
[RO]
Displays whether or not GPI Input_2 has
been switched to A2
• N/A
• Switch to A2
Group A GPI Input_3
[RO]
Displays whether or not GPI Input_3 has
been switched to Relay Bypass
• N/A
• Relay Bypass
Group A GPI Output_1
[RO]
Displays whether or not A1 is selected as
the current output source
• N/A
• Input A1 online
Group A GPI Output_2
[RO]
Displays whether or not A2 is selected as
the current output source
• N/A
• Input A2 online
Group A GPI Output_3
[RO]
Displays whether or not the relay bypass
has been activated
• N/A
• Signal Bypass
ACO Group A > MISC Settings
OutA OSD Enable
1, 4
Enables the on-screen display
Note
This parameter is not present in ASI
mode.
•
Off
• On
OutA EDH Control
1, 5
Inserts or clears the EDH when the input
online is SD-SDI
Note
This parameter is not available in
ASI mode, and is grayed out when the
selected input is HD.
•
Insert
• Clear
Table 6-1. ACO6800
+
IDSD
Parameters (Continued)
Group
Parameter Name
Bank,
Switch
Function
Options