Harris ACO6800+ASID Скачать руководство пользователя страница 1

ACO6800

+

ISD

Intelligent Single Switchover for SD/HD Sources
Basic Single Switchover for ASI Sources
ACO6800

+

DSD

Basic Dual Switchover for SD/HD Sources
Basic Dual Switchover for ASI Sources
ACO6800

+

IDSD

Intelligent Dual Switchover for SD/HD Sources
Basic Dual Switchover for ASI Sources
ACO6800

+

ASID

Intelligent Single Switchover for ASI Sources
ACO6800

+

ISCST

Intelligent Single, Clean/Quiet Switchover 
for SD/HD Sources
Basic Single Switchover for ASI Sources

Installation and Operation Manual

Edition B
175-100005-01

Содержание ACO6800+ASID

Страница 1: ...Dual Switchover for ASI Sources ACO6800 IDSD Intelligent Dual Switchover for SD HD Sources Basic Dual Switchover for ASI Sources ACO6800 ASID Intelligent Single Switchover for ASI Sources ACO6800 ISCST Intelligent Single Clean Quiet Switchover for SD HD Sources Basic Single Switchover for ASI Sources Installation and Operation Manual Edition B 175 100005 01 ...

Страница 2: ......

Страница 3: ...r SD HD Sources Basic Dual Switchover for ASI Sources ACO6800 IDSD Intelligent Dual Switchover for SD HD Sources Basic Dual Switchover for ASI Sources ACO6800 ASID Intelligent Single Switchover for ASI Sources ACO6800 ISCST Intelligent Single Clean Quiet Switchover for SD HD Sources Basic Single Switchover for ASI Sources Installation and Operation Manual ...

Страница 4: ...are periodically added to the information herein these changes will be incorporated into new editions of the publication Harris Corporation may make improvements and or changes in the product s and or the program s described in this publication at any time All trademarks are property of their respective owners Warranty Information The Limited Warranty Policy provides a complete description of your...

Страница 5: ...onic Equipment WEEE Compliance x Safety xii Safety Terms and Symbols in this Manual xii Chapter 1 Introduction Product Description 1 ACO6800 Features 1 Applications 4 Front Module 4 Back Modules 6 GPI Mating Connector 7 Signal Flow Diagrams 8 Chapter 2 Installation Unpacking the Module 11 Checking the Packing List 12 Maximum 6800 Frame Power Ratings 13 Installing the Modules 14 Upgrading Module Fi...

Страница 6: ...e 28 Step 2 Convert Files to the mg2 Format 29 Step 3 Transfer the Logos to the MicroSD Card 31 Using Trouble Slides 32 Chapter 4 ACO6800 ISD Parameters LEDs and Alarms On Screen Display Monitoring 35 Parameter Table Notes 35 ACO6800 ISD Parameters 36 ACO6800 ISD Subdevice Parameters 39 LEDs and Alarms 41 Monitoring LEDs 42 Module Status LEDs 43 Alarms 43 Chapter 5 ACO6800 DSD Parameters LEDs and ...

Страница 7: ...Parameter Changes 85 ACO6800 ISCST Parameters for SDI 87 ACO6800 ISCST Parameters for ASI 95 ACO6800 ISCST Subdevice Parameters 96 LEDs and Alarms 99 Monitoring LEDs 100 Module Status LEDs 101 Alarms 101 Chapter 9 Specifications Overview 105 Inputs 106 HD SD SDI Video 106 ASI Transport Stream 106 Genlock ACO6800 ISCST Only 107 Outputs 107 HD SD SDI Video 107 ASI Transport Stream Output Specificati...

Страница 8: ...vi ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Contents Appendix B Glossary Glossary of Terms 115 Index Keywords 119 ...

Страница 9: ...00 IDSD Intelligent Dual Switchover for SD HD Sources and Basic Dual Switchover for ASI Sources ACO6800 ASID Intelligent Single Switchover for ASI Sources ACO6800 ISCST Intelligent Single Clean Quiet Switchover for SD HD Sources and Basic Single Switchover for ASI Sources Audience This manual is written for engineers technicians and operators responsible for installation setup maintenance and or o...

Страница 10: ...icates E mail addresses the names of books or publications and the first instances of new terms and specialized words that need emphasis CAPS Indicates a specific key on the keyboard such as ENTER TAB CTRL ALT or DELETE Code Indicates variables or command line entries such as a DOS entry or something you type into a field Indicates the direction of navigation through a hierarchy of menus and windo...

Страница 11: ...vicing Except for firmware upgrades the modules are not designed for field servicing All hardware upgrades modifications or repairs require you to return the modules to the Customer Service center Returning a Product In the unlikely event that your product fails to operate properly contact Customer Service to obtain a Return Authorization RA number and then send the unit back for servicing If the ...

Страница 12: ... and lead free See our website for more information Spare parts supplied for the repair and upgrade of equipment sold before July 1 2006 are exempt from the legislation Equipment that complies with the EU directive will be marked with a RoHS compliant emblem as shown in Figure P 1 Figure P 1 RoHS Compliance Emblem Waste from Electrical and Electronic Equipment WEEE Compliance The European Union EU...

Страница 13: ...ices in the EU will affix labels indicating that such products must be properly recycled See our website for more information Contact your local Sales Representative for information on returning these products for recycling Equipment that complies with the EU directive will be marked with a WEEE compliant emblem as shown in Figure P 2 Figure P 2 WEEE Compliance Emblem ...

Страница 14: ...rical circuit If this product relies on forced air cooling all obstructions to the air flow should be removed prior to mounting the frame in the rack If this product has a provision for external earth grounding ground the frame to the earth using the protective earth ground on the rear panel IMPORTANT Only qualified personnel should perform service procedures Safety Terms and Symbols in this Manua...

Страница 15: ...h Automatic Switchover Provides QSEE driven 2 1 signal protection Switches signals between redundant signals at the point of ingest into a satellite DTH mobile TV or IPTV facility Switches signals just prior to arriving at the broadcast transmitter The ACO6800 ASID Intelligent Single Switch Automatic Switchover Switches the signal between redundant signals at the point of ingest into a satellite D...

Страница 16: ...O two inputs and two outputs Support for Q SEE compliant thumbnails when installed in an FR6802 QXF or FR6822 QXFE frame ACO6800 IDSD Dual ACOs Four BNC ports for each ACO two inputs and two outputs Independent Q SEE alarm sets for both inputs Support for Q SEE compliant thumbnails when installed in an FR6802 QXF or FR6822 QXFE frame ACO6800 ASID Single ACO Six BNC ports two inputs and four output...

Страница 17: ... slot module Yes Yes Yes Yes No Three slot module No No No No Yes Sub module needed No No No No Yes CCS Navigator support Yes Yes Yes Yes Yes Card edge control Yes Yes Yes No Yes Bypass relay Yes Yes Yes Yes Yes GPIs Yes Yes Yes Yes Yes Basic ASI support Yes Yes Yes Yes Yes Intelligent ASI support No No No Yes No 270 Mps Yes Yes Yes No Yes 1 5 Gbps Yes Yes Yes No Yes Q SEE switching Yes No Yes No ...

Страница 18: ...mobile television operations and IPTV operations to provide two signal sources with the ability to switch between the signals to play one on air Front Module Figure 1 1 shows the position of the LEDs and module controls on the front of the modules Figure 1 1 Typical Module Table 1 2 on page 5 briefly describes the LEDs switches and jumpers Module status LED Mode select rotary switch Navigation tog...

Страница 19: ...down through the available control parameters Down Moves down through the parameters Up Moves up through the parameters Control LEDs Various lighting combinations of these Control LEDs sometimes referred to as Bank Select LEDs indicate the currently selected bank See Bank Select LEDs on page 19 for more information Monitoring LEDs Each 6800 module has a number of LEDs assigned to indicate varying ...

Страница 20: ...e slot back module used by the ACO6800 ISCST module The back and front modules cannot be installed in frames without fans or in FR6802 DM and 6800 7000 series frames Figure 1 2 ACO6800 Back Modules IN 2 IN 1 OUT 2 OUT 1 AUX2 AUX1 GENLOCK GPI BYPASS IN 2 IN 1 OUT 2 OUT 1 IN 2 IN 1 OUT 2 OUT 1 GPI A GPI B A B BYPASS BYPASS IN 2 IN 1 OUT 2 OUT 1 NOT USED NOT USED OUT 2 OUT 1 GPI A NOT USED A B BYPASS...

Страница 21: ...ector Pinouts Table 1 3 GPI Functions GPI Function GPI In 1 Switch to IN 1 GPI In 2 Switch to IN 2 GPI In 3 Force relay to bypass signal IN 1 GPI Out 1 Indicate IN 1 is selected as output source GPI Out 2 Indicate IN 2 is selected as output source GPI Out 3 Indicate signal IN 1 is bypassed 1 5 6 10 1 GPI In 1 2 Ground 3 GPI In 2 4 Ground 5 GPI In 3 6 GPI Out 1 7 Ground 8 GPI Out 2 9 Ground 10 GPI ...

Страница 22: ...r 1 Introduction Signal Flow Diagrams Figure 1 4 Signal Flow Diagram for ACO6800 ISD and ACO6800 ASID Switch In 1A Switch logic Q SEE logic Out 1B Out 2B CPU Monitoring and Control Out 1A bypass Out 2A In 2A GPI in out A Note ACO6800 ASID does not support thumbnails in the Q SEE logic ...

Страница 23: ...ter 1 Introduction Figure 1 5 Signal Flow Diagram for ACO6800 DSD and ACO6800 IDSD Switch In 1A Switch logic Q SEE logic Out 1B bypass Switch In 1B Out 2B CPU Monitoring and Control Out 1A bypass Out 2A In 2A In 2B GPI in out A Switch logic Q SEE logic ACO6800 IDSD only GPI in out B ...

Страница 24: ...t 2009 Harris Corporation Chapter 1 Introduction Figure 1 6 Signal Flow Diagram for ACO6800 ISCST Switch In 1 Switch logic Q SEE logic AUX 2 AUX 1 CPU Monitoring and Control Out 1 bypass Out 2 In 2 GPI in out Frame and audio sync Trouble slide TSG Genlock ...

Страница 25: ...nsit Confirm receipt of all items on the packing list See Checking the Packing List on page 12 below for more information Note Contact your Customer Service representative if parts are missing or damaged Remove the anti static shipping pouch if present and all other packaging material Retain the original packaging materials for possible re use See Unpacking Shipping Information on page ix for info...

Страница 26: ...800 DSD ACO6800 IDSD ACO6800 ASID ACO6800 ISCST Installation and Operation Manual ACO6800 IDSD One ACO6800 front module One two slot back module One ACO6800 DS ACO6800 IDS back module overlay Two GPIO cables One license key One ACO6800 ISD ACO6800 DSD ACO6800 IDSD ACO6800 ASID ACO6800 ISCST Installation and Operation Manual ACO6800 ASID One ACO6800 front module One two slot back module One ACO6800...

Страница 27: ...To maintain proper temperatures ensure that the front panel is closed at all times and that the fan module is fully operational Table 2 2 Maximum Power Ratings for 6800 Frames 6800 Frame Type Max Frame Power Dissipation Max Power Dissipation for Two Slots Max Power Dissipation for Three Slots Max Number of ACO6800 ISD ACO6800 DSD ACO6800 ASID ACO6800 IDSD Modules Max Number of ACO6800 ISCST Module...

Страница 28: ...he 6800 Series Safety Instructions and Standards Manual shipped with every frame installation and operation manual This information is also available on our website The safety manual contains important information about the safe installation and operation of 6800 series products Upgrading Module Firmware Firmware upgrading is a routine procedure that you must perform to install newer versions of s...

Страница 29: ...d information on how to operate this product remotely see the Navigator NUCLEUS Network Control Panel or LCP 3901 1U RCP CCS 1U manual for Ethernet interface ACO6800 modules do not support Pilot Lite software however you can use HTTP or SNMP monitoring and control For detailed information see the installation and operation manual for your frame ...

Страница 30: ...Adding a License Key ACO6800 ISD ACO6800 DSD and ACO6800 IDSD modules can be converted to one another through use of a license key It is not possible to upgrade to an ACO6800 ISCST or ACO6800 ASID module Note For assistance with a license key or to purchase a license key contact your Sales representative See Checking the Packing List on page 12 To enter a license key your CCS software must be in C...

Страница 31: ...CS Navigator software must be in Build mode Follow these steps 1 If the Discovery pane is not open select Tools Discovery in the main menu A Discovery pane opens most likely in the bottom left corner of the screen 2 Click Options and then click Add 3 Enter the IP address of the frame that contains your module the frame that contains your ICE6800 module or the frame that contains a 6800 ETH module ...

Страница 32: ...not discovered re discover the module Figure 3 1 Discovery of ACO6800 Modules in CCS Navigator Card Edge Controls Using the module s rotary and navigation switches you can change ACO6800 parameter settings at the card edge You can view and confirm your changes using the On screen display feature see Activating On Screen Display on page 19 Note Card edge controls are not available for ACO6800 ASID ...

Страница 33: ... The manufacturer recommends that you use the available 6800 software control options serial local or Ethernet remote to aid in viewing setting and confirming parameter values Activating On Screen Display You can use the On Screen Display OSD Monitoring feature to view the current parameter selections on your output display This feature makes configuring the ACO6800 using the card edge controls mu...

Страница 34: ...ule to its default settings set the Factory Recall parameter 0 F to Enable Note There are two independent sets of default values one for SDI mode and the other for ASI mode Factory Recall in SDI mode will not affect the parameters in ASI mode nor will Factory Recall in ASI mode affect the parameters in SDI mode This does not apply to ACO6800 ASID Q SEE Compliant Thumbnails Note The ACO6800 ASID do...

Страница 35: ...0 ETH module s Control dialog box For more information on Q SEE compliant thumbnails see the installation and operation manual for your frame Relay Bypass When Group A or Group B Relay Bypass is activated Out 2 goes blank and the thumbnail and OSD are not available Group A or Group B Relay Bypass can be triggered in the following situations Power failure The Group A or Group B GPI In Trigger Level...

Страница 36: ...ority levels Group A or Group B Switch High Priority the default setting is GPI Input Group A or Group B Switch Medium Priority the default setting is Manual Group A or Group B Switch Low Priority the default setting is Alarms A high priority event overrides a medium priority event which overrides a low priority event The three options are mutually exclusive As an example the current settings migh...

Страница 37: ... Parameter Name Bank Switch Function Options ACO6800 ISD Group A Manual Switch 1 E Sets the output source when a channel is switched manually Disable Switch to A1 Switch to A2 ACO6800 DSD and ACO6800 IDSD Group A Manual Switch 1 E Sets the output source when a channel is switched manually Disable Switch to A1 Switch to A2 Group B Manual Switch 4 E Sets the output source when a channel is switched ...

Страница 38: ... configured correctly Group A B GPI Input_ 1 3 should confirm the GPI Input condition Group A or Group B Manual Switch should confirm the expected setting Group A or Group B Switch High Medium Low Priority should display the sort of logic seen in Table 3 6 and Table 3 8 Group A or Group B Alarm Switch Level should confirm the triggered level Confirm that the configurable portions of sub device ala...

Страница 39: ...ered 4 A user sets the Manual Switch to A1 Output A is A1 Manual has higher priority than Alarm 5 A user activates GPI Input 2 Output A is A2 GPI Input has higher priority than Manual 6 A user sets the Manual switch to Disable Output A is A2 7 A1 is present Output A is A2 GPI Input command is still active 8 Five seconds after A1 is present GPI Input 2 is deactivated Output A is A2 alarm for A1 is ...

Страница 40: ... 8 Sample Scenario Two Chain of Events Event Result 1 At the start A1 and A2 are both present and 625 format Output A is A1 A1 Standard Mismatch alarm is on but has not met switching condition level 6 2 A1 is lost Output A is A1 A1 and A2 inputs are bad but A2 Standard Mismatch alarm level is 6 so the ACO6800 selects primary input as output 3 A user sets the Manual Switch to A2 Output A is A1 A2 i...

Страница 41: ... Still Image Priority and Image Output When Still Image Mode is set to Auto Switch High Priority Switch Medium Priority Switch Low Priority Output Source Note Table 3 10 Still Image Output on ACO6800 ISCST Modules Still Image Mode Still Image Source LOV Mode Result Auto TSG Trouble Slide Pass The output temporarily passes some video noise and then switches over to the still image Auto TSG Trouble ...

Страница 42: ...s follows 1 Install the LogoCreator conversion software from the IconSoft Tools CD ROM 2 Convert the logos to an mg2 format 3 Transfer the files to the microSD card directly from the PC Step 1 Install LogoCreator Software All logos used by the ACO6800 ISCST must either be generated as mg2 files or converted to that format A version of LogoCreator located on the IconSoft Tools CD ROM is provided wi...

Страница 43: ...ages to the same size resolution as the standard of the ACO6800 ISCST output LogoCreator infers the key from the alpha channel in a targa tga file After you save the logo the logo displays in your LogoCreator workspace To save your logo files using LogoCreator follow these steps 1 In LogoCreator open the Logo Set Up dialog box Figure 3 3 below When you first open LogoCreator the Logo Set Up dialog...

Страница 44: ...u can save the logo To use the original image s alpha channel select the Use the alpha key found with image checkbox To use a different image for the alpha channel clear the Use the alpha key found with image checkbox and then click the Open button to select a new file for your alpha channel Note An alpha channel is an 8 bit layer in a graphics file format that expresses transparency Typically you...

Страница 45: ... strength of the key signal and apply fade on off transitions to the logo Step 3 Transfer the Logos to the MicroSD Card When your logos have been created or converted to the mg2 format they can be saved on the microSD card The ACO6800 ISCST references files on the MicroSD card using the DOS 8 3 short filename convention Longer filenames may be accessed by entering the alternate 8 3 filename To avo...

Страница 46: ... parameter has four options The Trouble Slide 1 2 3 options are only available when there are compatible trouble slides MG2 format stored in the microSD card The trouble slide can have two sources Default trouble slides are stored within the firmware of the ACO6800 You can only change the background portion of default trouble slides using parameter Trouble Slide Background Up to three user trouble...

Страница 47: ...eo size is 1280 720 if the image size is 720 576 it is acceptable If it is 1920 1280 it would be refused For best results the length of file name should be less or equal to 8 letters If the length of mg2 file name is larger than 8 characters a shortened name will display on Navigator Only the first three valid MG2 files sorted by access time are displayed on Navigator For best results the original...

Страница 48: ...34 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Chapter 3 Configuration and Operation ...

Страница 49: ... For information on enabling OSD monitoring see Activating On Screen Display on page 19 Parameter Table Notes When you look at the control parameter tables note the following Shaded table rows and RO after the parameter name indicate read only feedback parameters Bolded parameter options indicate the default settings for the parameter The bank selection and rotary switch combinations for each para...

Страница 50: ...I mode and vice versa On Off Soft Reboot 0 E Activates a soft reboot of the module On Off Operation Mode 0 1 Sets the ACO work mode to SDI or ASI Note Factory recall does not change this parameter It has no default value SDI ASI Thumbnail Source 0 2 Selects the thumbnail source Note This parameter is not available in ASI mode Input A1 Input A2 Output GrpA Submodule Type RO Displays whether or not ...

Страница 51: ...Level 1 3 Sets the level at which an alarm is triggered for the Group A GPI Output Active Low Active High Group A GPI Input_1 RO Displays whether or not GPI Input_1 has been switched to A1 N A Switch to A1 Group A GPI Input_2 RO Displays whether or not GPI Input_2 has been switched to A2 N A Switch to A2 Group A GPI Input_3 RO Displays whether or not GPI Input_3 has been switched to Relay Bypass N...

Страница 52: ...mode and is grayed out when the selected input is HD Insert Clear ACO Group A Out B Settings OutB Source 4 6 Select output source for Out B Follow Out A Input A1 Input A2 OutB EDH Control 4 7 Inserts or clears the EDH when the input online is SD SDI Note This parameter is not available in ASI mode and is grayed out when the selected input is HD Insert Clear Table 4 1 ACO6800 ISD Parameters Continu...

Страница 53: ...io group package On Off SQM Settings Set Expected Video Standard A1 A2 2 1 3 1 Selects the expected format Note When the format deviates from this format one of the SDI Video Standard Mismatch alarms triggers 525 625 1080i 1080p 720p 1080psf Luma Low Threshold A1 A2 2 2 3 2 Sets the threshold below which the SDI Luma Low alarm is triggered 6 8 to 15 7 5 Luma Peak Threshold A1 A2 2 3 3 3 Sets the t...

Страница 54: ...FS to 30 dBFS 60 dBFS Loss of Sound Threshold dBFS A1 A2 2 9 3 9 Sets the threshold below which SDI Embedded Ch01 Loss of Sound to SDI Embedded Ch16 Loss of Sound alarms are triggered 100 dBFS to 60 dBFS 90 dBFS Audio Average Level Reporting A1 A2 2 A 3 A Displays the SDI Embedded Channel Average Level value Enable Disable Audio Average Level Restart A1 A2 2 B 3 B Restarts the calculation of the a...

Страница 55: ...ms LEDs and Alarms The ACO6800 ISD modules have LEDs that serve as a quick monitoring reference and one module status LED Figure 4 1 shows the location of the LEDs on a typical ACO6800 ISD module Table 4 3 and Table 4 4 describe each LED in more detail Figure 4 1 Location of ACO6800 ISD LEDs Monitoring LEDs Module status LED ...

Страница 56: ...on 1 Out A LED 1 The current selected input is 1A for group A Green 2 Out A LED 2 The current selected input is 2A for group A Green 3 IN 1A Present Input 1A signal is present Green 4 IN 1A Alarm Input 1A is in an alarm state Amber 5 IN 2A Present Input 2A signal is present Green 6 IN 2A Alarm Input 2A is in an alarm state Amber 7 Out B LED 1 Not used 8 Out B LED 2 9 IN 1B Present 10 IN 1B Alarm 1...

Страница 57: ...pplication See the appropriate software control user manual or online help for more information The following settings can be made for each alarm within the software Table 4 4 Module Status LED Descriptions LED Color Sequence Meaning Off There is no power to the module the module is not operational Green There is power to the module the module is operating properly Red There is an alarm condition ...

Страница 58: ...s the amount of time the alarm condition must be in abate in order for the alarm to be turned off Choose any duration from 0 to 7200 seconds or 2 hours If this option is set to 0 and the alarm condition ceases for any period of time the alarm will clear Ack When an alarm is active click here to allow other users on the network to see that you have acknowledged the alarm Table 4 5 Alarm Options Ala...

Страница 59: ...D chroma component remains below the threshold defined by the Chroma Low Threshold parameter 1 30 0 2 0 SDI Video Black Reports that the HD or SD video level does not exceed the level defined by the Video Black Threshold parameter 6 240 0 2 0 SDI CC XDS Data Missing 525 only Reports that the standard definition CC Extended Data Services on line 21 field 2 is not detected 1 240 0 2 0 SDI VChip Data...

Страница 60: ...hold parameter 1 30 0 2 0 SDI Embedded Ch 01 16 Missing Reports if the SDI embedded audio channel is missing 1 1 0 2 0 SDI Embedded Audio Group 1 4 Missing Reports that the audio in the specified group is not present 1 1 0 2 0 ASI Mode ASI Error Reports an ASI error including ASI loss in streaming 1 1 0 2 0 Table 4 7 ACO6800 ISD Subdevice Alarms Continued Alarm Name Alarm Description Alarm Option ...

Страница 61: ... For information on enabling OSD monitoring see Activating On Screen Display on page 19 Parameter Table Notes When you look at the control parameter tables note the following Shaded table rows and RO after the parameter name indicate read only feedback parameters Bolded parameter options indicate the default settings for the parameter The bank selection and rotary switch combinations for each para...

Страница 62: ... versa On Off Soft Reboot 0 E Activates a soft reboot of the module On Off Operation Mode 0 1 Sets the ACO work mode to SDI or ASI Note Factory recall does not change this parameter It has no default value SDI ASI Thumbnail Source 0 2 Selects the thumbnail source Note This parameter is not available in ASI mode Input A1 Input A2 Input B1 Input B2 Output GrpA Output GrpB Submodule Type RO Displays ...

Страница 63: ...tive High Group A GPI Input_1 RO Displays whether or not GPI Input_1 has been switched to A1 N A Switch to A1 Group A GPI Input_2 RO Displays whether or not GPI Input_2 has been switched to A2 N A Switch to A2 Group A GPI Input_3 RO Displays whether or not GPI Input_3 has been switched to Relay Bypass N A Relay Bypass Group A GPI Output_1 RO Displays whether or not A1 is selected as current output...

Страница 64: ...relay bypass On Off Group B Relay Status RO Displays whether the relay is active or not On Off ACO Group B General Purpose Interface Group B GPI In Trigger Level 4 2 Sets the level at which an alarm is triggered for the Group B GPI Input Active Low Active High Group B GPI Out Trigger Level 4 3 Sets the level at which an alarm is triggered for the Group B GPI Output Active Low Active Level Group B ...

Страница 65: ...ted input is HD Insert Clear Table 5 1 ACO6800 DSD Parameters Continued Group Parameter Name Bank Switch Function Options Table 5 2 ACO6800 DSD Subdevice Parameters Group Parameter Name Bank Switch Function Options Parameters available in SDI Mode Status Video Present RO Indicates that video is present On Off Video Standard RO Lists the incoming video standard string SQM Settings Set Expected Vide...

Страница 66: ...ms LEDs and Alarms The ACO6800 DSD modules have LEDs that serve as a quick monitoring reference and one module status LED Figure 5 1 shows the location of the LEDs on a typical ACO6800 DSD module Table 5 3 and Table 5 4 describe each LED in more detail Figure 5 1 Location of ACO6800 DSD LEDs Monitoring LEDs Module status LED ...

Страница 67: ...or group A Green 3 IN 1A Present Input 1A signal is present Green 4 IN 1A Alarm Input 1A is in an alarm state Amber 5 IN 2A Present Input 2A signal is present Green 6 IN 2A Alarm Input 2A is in an alarm state Amber 7 Out B LED 1 The current selected input is 1B for group B Green 8 Out B LED 2 The current selected input is 2B for group B Green 9 IN 1B Present Input 1B signal is present Green 10 IN ...

Страница 68: ...pplication See the appropriate software control user manual or online help for more information The following settings can be made for each alarm within the software Table 5 4 Module Status LED Descriptions LED Color Sequence Meaning Off There is no power to the module the module is not operational Green There is power to the module the module is operating properly Red There is an alarm condition ...

Страница 69: ...ill trigger Clear s Determines the amount of time the alarm condition must be in abate in order for the alarm to be turned off Choose any duration from 0 to 7200 seconds or 2 hours If this option is set to 0 and the alarm condition ceases for any period of time the alarm will clear Ack When an alarm is active click here to allow other users on the network to see that you have acknowledged the alar...

Страница 70: ...56 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Chapter 5 ACO6800 DSD Parameters LEDs and Alarms ...

Страница 71: ...s For information on enabling OSD monitoring see Activating On Screen Display on page 19 Parameter Table Notes When you look at the control parameter tables note the following Shaded table rows and RO after the parameter name indicate read only feedback parameters Bolded parameter options indicate the default settings for the parameter The bank selection and rotary switch combinations for each par...

Страница 72: ...ce versa On Off Soft Reboot 0 E Activates a soft reboot of the module On Off Operation Mode 0 1 Sets the ACO work mode to SDI or ASI Note Factory recall does not change this parameter It has no default value SDI ASI Thumbnail Source 0 2 Selects the thumbnail source Note This parameter is not available in ASI mode Input A1 Input A2 Input B1 Input B2 Output GrpA Output GrpB Submodule Type RO Display...

Страница 73: ...e High Group A GPI Input_1 RO Displays whether or not GPI Input_1 has been switched to A1 N A Switch to A1 Group A GPI Input_2 RO Displays whether or not GPI Input_2 has been switched to A2 N A Switch to A2 Group A GPI Input_3 RO Displays whether or not GPI Input_3 has been switched to Relay Bypass N A Relay Bypass Group A GPI Output_1 RO Displays whether or not A1 is selected as the current outpu...

Страница 74: ...ay bypass On Off Group B Relay Status RO Displays whether the relay is active or not On Off ACO Group B General Purpose Interface Group B GPI In Trigger Level 4 2 Sets the level at which an alarm is triggered for the Group B GPI Input Active Low Active High Group B GPI Out Trigger Level 4 3 Sets the level at which an alarm is triggered for the Group B GPI Output Active Low Active High Group B GPI ...

Страница 75: ...800 IDSD Parameters Continued Group Parameter Name Bank Switch Function Options Table 6 2 ACO6800 IDSD Subdevice Parameters Group Parameter Name Bank Switch Function Options Parameters available in SDI Mode Status Video Present RO Indicates that video is present On Off Video Standard RO Lists the incoming video standard Audio Grp 1 4 Present Displays the presence of the specified audio group packa...

Страница 76: ... SDI Video Black alarm is triggered 0 to 10 5 5 Peak Audio Threshold dBFS A1 A2 B1 B2 2 7 3 7 5 7 6 7 Sets the threshold above which SDI Embedded Ch01 peak to SDI Embedded Ch02 peak alarms are triggered 20 dBFS to 0 dBFS 2 dBFS Low Audio Threshold dBFS A1 A2 B1 B2 2 8 3 8 5 8 6 8 Sets the threshold below which SDI Embedded Ch01 Low Audio to SDI Embedded Ch16 Low Audio alarms are triggered 80 dBFS ...

Страница 77: ...the calculation of the average audio level On Off SQM SDI Emb Ch1 16 Average Level dBFS RO Displays the embedded audio average level for the channel 99 dBFS to 0 dBFS Parameters available in ASI Mode Status ASI Error RO Displays whether or not there is an ASI error including ASI loss On Off Table 6 2 ACO6800 IDSD Subdevice Parameters Continued Group Parameter Name Bank Switch Function Options ...

Страница 78: ...s LEDs and Alarms The ACO6800 IDSD modules have LEDs that serve as a quick monitoring reference and one module status LED Figure 6 1 shows the location of the LEDs on a typical ACO6800 IDSD module Table 6 3 and Table 6 4 describe each LED in more detail Figure 6 1 Location of ACO6800 IDSD LEDs Monitoring LEDs Module status LED ...

Страница 79: ...for group A Green 3 IN 1A Present Input 1A signal is present Green 4 IN 1A Alarm Input 1A is in an alarm state Amber 5 IN 2A Present Input 2A signal is present Green 6 IN 2A Alarm Input 2A is in an alarm state Amber 7 Out B LED 1 The current selected input is 1B for group B Green 8 Out B LED 2 The current selected input is 2B for group B Green 9 IN 1B Present Input 1B signal is present Green 10 IN...

Страница 80: ...application See the appropriate software control user manual or online help for more information The following settings can be made for each alarm within the software Table 6 4 Module Status LED Descriptions LED Color Sequence Meaning Off There is no power to the module the module is not operational Green There is power to the module the module is operating properly Red There is an alarm condition...

Страница 81: ... time the alarm condition must be in abate in order for the alarm to be turned off Choose any duration from 0 to 7200 seconds or 2 hours If this option is set to 0 and the alarm condition ceases for any period of time the alarm will clear Ack When an alarm is active click here to allow other users on the network to see that you have acknowledged the alarm Table 6 5 Alarm Options Alarm Option Effec...

Страница 82: ...D chroma component remains below the threshold defined by the Chroma Low Threshold parameter 1 30 0 2 0 SDI Video Black Reports that the HD or SD video level does not exceed the level defined by the Video Black Threshold parameter 6 240 0 2 0 SDI CC XDS Data Missing 525 only Reports that the standard definition CC Extended Data Services on line 21 field 2 is not detected 1 240 0 2 0 SDI VChip Data...

Страница 83: ...hold parameter 1 30 0 2 0 SDI Embedded Ch 01 16 Missing Reports if the SDI embedded audio channel is missing 1 1 0 2 0 SDI Embedded Audio Group 1 4 Missing Reports that the audio in the specified group is not present 1 1 0 2 0 ASI Mode ASI Error Reports an ASI error including ASI loss in streaming 1 1 0 2 0 Table 6 7 ACO6800 IDSD Subdevice Alarms Continued Alarm Name Alarm Description Alarm Option...

Страница 84: ...70 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Chapter 6 ACO6800 IDSD Parameters LEDs and Alarms ...

Страница 85: ...parameter tables note the following Shaded table rows and RO after the parameter name indicate read only feedback parameters Bolded parameter options indicate the default settings for the parameter The parameters are listed in the order that they appear in CCS Navigator Note For a clarification of terms and acronyms in the following lists refer to Appendix A Glossary on page 115 ...

Страница 86: ...ty Sets the low priority for switching GPI Input Manual Alarms Alarm Switch Level Sets the level for alarm auto switch 1 to 10 6 Manual Switch Sets what the output source will be when a channel is switched manually Disable Switch to A1 Switch to A2 Alarm Switch Mode Sets the module for Automatic non resetting mode Automatic returns to primary input after alarm clears and non resetting must be swit...

Страница 87: ...tings OutB Source Select the output source for Out B Follow Out A Input 1 Input 2 Table 7 1 ACO6800 ASID Parameters Continued Group Parameter Name Function Options Group Parameter Name Function Options Parameters Status CRC Change PAT CRC_change RO Displays the current alarm status Indicator On Indicator Off PMT CRC_change RO Displays the current alarm status Indicator On Indicator Off CAT CRC_cha...

Страница 88: ...tus Indicator On Indicator Off DVB BAT CRC_error RO Displays the current alarm status Indicator On Indicator Off DVB SDT CRC_error RO Displays the current alarm status Indicator On Indicator Off DVB EIT CRC_error RO Displays the current alarm status Indicator On Indicator Off DVB TOT CRC_error RO Displays the current alarm status Indicator On Indicator Off ATSC MGT CRC_error RO Displays the curren...

Страница 89: ...ers Parameter Settings ETR 290 Priority 1 Alarms PAT Repetition Allows selection of the PAT repetition rate for alarm detection 0 1 to 5 seconds PMT Repetition Allows selection of the discontinuity threshold for alarm detection 0 1 to 5 seconds PID Repetition Allows selection of the PID repetition threshold for alarm detection 0 to 60 seconds Parameters Parameter Settings ETR 290 Priority 2 Alarms...

Страница 90: ...r DVB NIT alarm On Off DVB BAT CRC_error Activates the CRC Error DVB BAT alarm On Off DVB SDT CRC_error Activates the CRC Error DVB SDT alarm On Off DVB EIT CRC_error Activates the CRC Error DVB EIT alarm On Off DVB TOT CRC error Activates the CRC Error DVB TOT alarm On Off ATSC MGT CRC_error Activates the CRC Error ATSC MGT alarm On Off ATSC TVCT CRC_error Activates the CRC Error ATSC TVCT alarm ...

Страница 91: ...DVB BAT CRC_change Activates the CRC Change DVB BAT alarm On Off DVB SDT CRC_change Activates the CRC Change DVB SDT alarm On Off DVB EIT CRC_change Activates the CRC Change DVB EIT alarm On Off ATSC MGT CRC_change Activates the CRC Change ATSC MGT alarm On Off ATSC TVCT CRC_change Activates the CRC Change ATSC TVCT alarm On Off ATSC CVCT CRC_change Activates the CRC Change ATSC CVCT alarm On Off ...

Страница 92: ...s LEDs and Alarms The ACO6800 ASID modules have LEDs that serve as a quick monitoring reference and one module status LED Figure 7 1 shows the location of the LEDs on a typical ACO6800 ASID module Table 7 2 and Table 7 3 describe each LED in more detail Figure 7 1 Location of ACO6800 ASID LEDs Monitoring LEDs Module status LED ...

Страница 93: ...g LEDs Indicators LED Name Description Color Indication 1 Out A LED 1 The current selected input is 1A for group A Green 2 Out A LED 2 The current selected input is 2A for group A Green 3 IN 1A Present Input 1A signal is present Green 4 IN 1A Alarm Input 1A is in an alarm state Amber 5 IN 2A Present Input 2A signal is present Green 6 IN 2A Alarm Input 2A is in an alarm state Amber 7 Out B LED 1 No...

Страница 94: ...as major or minor The range is 1 10 A priority of 6 or higher is a major alarm and a priority of 5 or lower is a minor alarm Trigger s This option determines how long an alarm condition must exist in seconds before the alarm is triggered If the alarm level is reached for less time than the Trigger duration then the alarm will not trigger Choose any duration from 0 to 7200 or 2 hours If this option...

Страница 95: ...DVB EIT DVB MGT ATSC TVCT ATSC CVCT ATSC RRT ATSC EIT ATSC and ETT ATSC This error must be cleared manually on the parameter page once the alarm is activated 2 0 5 TS Sync loss Reports that the module input has lost synchronization with the input source 6 2 5 Sync Byte error Reports that the Sync byte is not present in a transport stream packet 188 or 204 bytes 4 2 5 PAT error Reports one or more ...

Страница 96: ... PCR discontinuity of more than the selected period Time interval between two consecutive PCR values more than the selected repetition period spec 40 ms The PCR Accuracy Repetition rate and Discontinuity rate adjustments are on the ETR 290 Priority 2 Alarms page on the Parameters tab The PCR PID alarm s must also be must be enabled on the ETR 290 Priority 2 Alarms page 2 2 5 PCR accuracy error Rep...

Страница 97: ...the ETR 290 Priority 2 Alarms page on the Parameters tab 2 2 5 CAT error Reports one or more of the following 1 Packets with transport scrambling control not 00 present and no section with table id 0x01present 2 Section with table id other than 0x01 not a CAT found on PID 0x0001 2 2 5 information taken from ETR290 May 1997 Table 7 6 ACO6800 ASID Subdevice Alarms Alarm Name Alarm Description Alarm ...

Страница 98: ...84 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Chapter 7 ACO6800 ASID Parameters LEDs and Alarms ...

Страница 99: ... When you look at the control parameter tables note the following Shaded table rows and RO after the parameter name indicate read only feedback parameters Bolded parameter options indicate the default settings for the parameter The bank selection and rotary switch combinations for each parameter and parameter option are listed in the tables under the Bank Switch heading For more information about ...

Страница 100: ...able AUX EDH Audio Processing SRC Bypass SRC Bypass Mode Auto SRC 1 8 Bypass Audio Processing SRC Bypass SRC Bypass Yes Note Note if the SRC Bypass Mode is Auto and the audio package is detected as Data ACO6800 ISCST will automatically switch SRC Bypass to Yes Gain Lock Gain All Gain ch L R Invert All Invert ch L R Audio Processing Delay Delay Lock Yes Delay 1 16 ch 1 L ch 8 R No Delay All Audio P...

Страница 101: ...n ASI mode and vice versa On Off Soft Reboot 0 E Activates a soft reboot of the module On Off Operation Mode 0 1 Sets the ACO work mode to SDI or ASI Note Factory recall does not change this parameter It has no default value SDI ASI SubmoduleType RO Shows whether there is a submodule included on the module None For ISCS Back Module Type Displays the type of back module connected to the front modul...

Страница 102: ...larms Switch Medium Priority 1 B Sets the medium priority for switching GPI Input Manual Alarms Switch Low Priority 1 C Sets the low priority for switching GPI Input Manual Alarms Alarms Switch Level 1 D Sets the level for alarm auto switch 1 to 10 6 Manual Switch 1 E Sets the what the output source will be when a channel is switched manually Disable IN_1 IN_2 Relay Bypass 1 1 Determines whether o...

Страница 103: ...al Bypass Video LOV Mode 4 1 Determines the processing mode when there is a loss of video on the selected input Pass Black Freeze Still Image Mode 4 2 Forces the output to a still image see Table 3 10 on page 27 for details Auto Force Still Image Source 4 3 Selects the source for the still image Trouble Slide TSG None Test Signal Generator Pattern 4 4 Selects the TSG pattern Black 75 Color Bar 100...

Страница 104: ...le Slide Background 4 6 Select the background for default trouble slide Black 75 Color Bar 100 Color Bar H Sweep Multiburst Ramp SD Card Status RO Indicates whether the SD card is available Absent Not Compatible Please Select File Loading File File Loaded Name of Trouble Slide 1 3 RO Displays the trouble slide name stored on SD card string Video Video Procamp Luma Gain 5 1 Sets the video luminance...

Страница 105: ...tion frame rate IRE 59 94 ore mV 50 6 8 to 6 8 IRE 0 47 9 to 47 9 mV 0 Video Out 1_2 Settings OSD Enable 5 C Activates the on screen display on outputs 1 and 2 On Off EDH 5 D Activates the EDH insert after frame synchronizer Note Only available when the operation standard is 525 or 625 Insert Clear Video AUX Settings AUX Output Source 1 F Sets the backup channel s output source Note When Frame Syn...

Страница 106: ...ets the audio output behavior when the audio has an error Repeat Mute SDI DBN Error Control Sets the reporting behavior when the audio has a DBN error Alert Ignore SDI Group Error Status Reports group errors for SDI audio On Off SDI DBN Error Status Reports DBN errors for SDI audio On Of Audio Processing SRC Bypass SRC Bypass Mode 6 D Sets the SRC control mode Note When this parameter is set to Au...

Страница 107: ...n Gain Lock 8 3 Sets the audio gain separately or for all channels Yes No Gain All 8 4 Adjusts the audio gain for all channels when Gain Lock is enabled 18 dB to 18 dB 0 Gain 1 Ch1 L and Gain 2 Ch1 R to Gain 15 Ch 8 L and Gain 16 Ch8 R Adjusts the audio gain for each channel when Gain Lock is disabled Note The gain control is disabled when the SRC is set to Bypass 18 dB to 18 dB 0 Audio Processing...

Страница 108: ...Group Format Follow Input is disabled On Off Audio Output Routing Out Ch 1 L 8 R 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 Sets an audio source for the SD HD embedder In Ch1 L Out Ch1 L In Ch1 R Out Ch1 R In Ch2 L Out Ch2 L In Ch2 R Out Ch2 R In Ch3 L Out Ch3 L In Ch3 R Out Ch3 R In Ch4 L Out Ch4 L In Ch4 R Out Ch4 R In Ch5 L Out Ch5 L In Ch5 R Out Ch5 R In Ch6 L Out Ch6 L In...

Страница 109: ... Activates a soft reboot of the module Enable Disable Operation Mode 0 1 Sets the ACO work mode to SDI or ASI Note Factory recall does not change this parameter It has no default value SDI ASI SubmoduleType RO Shows whether there is a submodule included on the module None For ISCS Back Module Type Displays the type of back module connected to the front module For DS IDS For ISCS System Switch Sett...

Страница 110: ...igh Level GPI Output Trigger Level 1 3 Sets the trigger level for GPI Output Group A Low Level High Level System General Purpose Interface Continued GPI Input_1 RO Displays whether or not GPI Input_1 has been switched to A1 N A Switch to IN_1 GPI Input_2 RO Displays whether or not GPI Input_2 has been switched to A2 N A Switch to IN_2 GPI Input_3 RO Displays whether or not GPI Input_3 has been swi...

Страница 111: ...nce triggers the SDI Luma Peak alarm 90 to 108 102 Chroma Low Threshold IN 1 IN 2 2 4 3 4 Sets the threshold below which the SDI Chroma Low alarm is triggered 0 to 15 0 Chroma Peak Threshold IN 1 IN 2 2 5 3 5 Sets the threshold at or above which excessive chrominance level triggers the SDI Chroma Peak alarm 90 to 108 102 Video Black Threshold IN 1 IN 2 2 6 3 6 Sets the threshold below which the SD...

Страница 112: ... Audio Average Level Restart IN 1 IN 2 2 B 3 B Restarts the calculation of the average audio level On Off SQM SDI Emb Ch1 16 Average Level dBFS Displays the embedded audio average level for the channel 99 dBFS to 0 dBFS Parameters available in ASI Mode Status ASI Error RO Displays where or not there is an ASI error including ASI loss On Off Table 8 4 ACO6800 ISCST Subdevice Parameters Continued Gr...

Страница 113: ... LEDs and Alarms The ACO6800 ISCST modules have LEDs that serve as a quick monitoring reference and one module status LED Figure 8 1 shows the location of the LEDs on a typical ACO6800 ISCST module Table 8 5 and Table 8 6 describe each LED in more detail Figure 8 1 Location of ACO6800 ISCST LEDs Monitoring LEDs Module status LED ...

Страница 114: ... 1 Out A LED 1 The current selected input is IN 1 Green 2 Out A LED 2 The current selected input is IN 2 Green 3 IN 1A Present Input 1 signal is present Green 4 IN 1A Alarm Input 1 is in an alarm state Amber 5 IN 2A Present Input 2 signal is present Green 6 IN 2A Alarm Input 2 is in an alarm state Amber 7 Out B LED 1 Not used 8 Out B LED 2 9 Genlock Present Genlock is present Green 10 Genlock Alar...

Страница 115: ... application See the appropriate software control user manual or online help for more information The following settings can be made for each alarm within the software Table 8 6 Module Status LED Descriptions LED Color Sequence Meaning Off There is no power to the module the module is not operational Green There is power to the module the module is operating properly Red There is an alarm conditio...

Страница 116: ...e in order for the alarm to be turned off Choose any duration from 0 to 7200 seconds or 2 hours If this option is set to 0 and the alarm condition ceases for any period of time the alarm will clear Ack When an alarm is active click here to allow other users on the network to see that you have acknowledged the alarm Table 8 7 Alarm Options Alarm Option Effect Table 8 8 Device Alarms For ACO6800 ISC...

Страница 117: ... 0 SDI Chroma Low Reports that the HD or SD chroma component remains below the threshold defined by the Chroma Low Threshold parameter 1 30 0 2 0 SDI Video Black Reports that the HD or SD video level does not exceed the level defined by the Video Black Threshold parameter 6 240 0 2 0 SDI CC XDS Data Missing 525 only Reports that the standard definition CC Extended Data Services on line 21 field 2 ...

Страница 118: ...shold parameter 1 30 0 2 0 SDI Embedded Ch 01 16 Missing Reports if the SDI embedded audio channel is missing 1 1 0 2 0 SDI Embedded Audio Group 1 4 Missing Reports that the audio in the specified group is not present 1 1 0 2 0 ASI Mode ASI Error Reports an ASI error including ASI loss in streaming 1 1 0 2 0 Table 8 9 ACO6800 ISCST Subdevice Alarms Continued Alarm Name Alarm Description Alarm Opti...

Страница 119: ...les appear in this chapter Inputs HD SD SDI Video on page 106 Genlock ACO6800 ISCST Only on page 107 Outputs HD SD SDI Video on page 107 Miscellaneous General Purpose Interface on page 108 Propagation Delay on page 109 Power Consumption on page 109 Operating Temperature on page 110 Specifications and designs are subject to change without notice ...

Страница 120: ...M 1080i 59 94 1080i 50 1080p 25 1080p 23 98 SMPTE296M 720p 59 94 720p 50 SMPTE 259M C 270 Mbps 525 625 component video Connector BNC per IEC 169 8 BNC per IEC 169 8 Impedance 75Ω 75Ω Return loss 15 dB typical from 5 MHz to 1485 MHz 15 dB typical from 5 MHz to 270 MHz Equalization Adaptive cable equalization for up to 393 ft 120 m typical of Belden 1694A coaxial cable Up to 918 ft 280 m for Belden ...

Страница 121: ...umber of outputs 4 Standards ACO6800 ISD ACO6800 DSD and ACO6800 IDSD SMPTE274M 1080i 60 1080i 59 94 1080i 50 1080p 30 1080p 29 97 1080p 25 1080p 24 1080p 23 98 SMPTE296M 720p 60 720p 59 94 720p 50 SMPTE RP 211 2000 1080psf 24 1080psf 23 98 ACO6800 ISCST SMPTE274M 1080i 59 94 1080i 50 1080p 25 1080p 23 98 SMPTE296M 720p 59 94 720p 50 SMPTE 259M C 270 Mbps 525 625 component video Connector BNC per ...

Страница 122: ...loss 15 dB typical from 5 MHz to 270 MHz Signal level 800 mV 10 D C offset 0 0 V 0 5 V Rise and fall time 400 ps to 1500 ps 20 to 80 Overshoot 10 of amplitude Jitter 0 2 UI pk to pk Table 9 6 GPI O Interface Specifications Item Specification GPI inputs transmitter Number 6 for ACO6800 DSD and ACO6800 IDSD 3 for ACO6800 ISCST ACO6800 ASID and ACO6800 ISD Internally pulled HIGH External contact clos...

Страница 123: ...1080i 50 1080p 25 1080p 24 720p 50 1080i 60 1080p 30 720p 60 1 0 µsec Table 9 8 ACO6800 ISCST Propagation Delay Specifications Frame Rate Standard Propagation Delay 59 94 Hz 525 1 frame 1080i 1 frame 720p 1 frame 50 Hz 625 1 frame 1080i 1 frame 720p 1 frame 23 98 Hz 1080p 1 frame 25 Hz 1080p 1 frame Table 9 9 ACO6800 ASID Propagation Delay Specifications Standard Propagation Delay ASI 30 µsec typi...

Страница 124: ...is Corporation Chapter 9 Specifications Operating Temperature The operating temperature for ACO6800 modules is 41 to 113 F 5 to 45 C ACO6800 IDSD 12 W ACO6800 ASID 12 W ACO6800 ISCST 13 W Table 9 10 Power Consumption Specifications Continued Module Power Consumption ...

Страница 125: ... the frame Remove any legacy 6800 series product that is in the frame CCS software cannot communicate with legacy 6800 series products even though these modules may operate with card edge controls in an FR6802 frame Legacy 6800 products do not have the symbol on their extractor handles Check for bent pins on the back module by following this procedure a Unplug the front module b Unscrew and remove...

Страница 126: ...CCS software shows a module in the Control window but cannot control it Solution 1 Set the module s Local Remote jumper to Remote 2 Ensure the module name in the Control window matches the module type in the frame 3 Gently push the module into its slot in the frame to ensure it is seated properly and powered up 4 Verify that the Control window indicates the device is ready Hardware Communication P...

Страница 127: ... are secure Gently push the module into its slot in the frame to ensure it is seated properly Ensure the back module does not have bent pins by following this procedure a Unplug the front module b Unscrew and remove the back module c Inspect the spring connector at the bottom of the back module Figure A 1 and verify the connector does not have any slightly bent or pressed pins d Carefully repositi...

Страница 128: ...114 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Appendix A Communication and Control Troubleshooting Tips ...

Страница 129: ...CT Defines the virtual channel structure for the collection of MPEG 2 programs embedded in the Transport Stream in which the CVCT is carried Conditional Access CA An encryption decryption management method security system where the broadcaster controls the subscriber s access to digital and Interactive TV services Conditional Access Table CAT Contains CA descriptors which identify PID values for C...

Страница 130: ...n Profile at Main Level The Master Guide Table MGT Provides general information about all of the other tables Defines the type size packet identifiers and versions for all the other PSIP tables in this Transport Stream except for the System Time Table STT Mbps Megabits per second mV Millivolts MP HL Main Profile at High Level MP ML Main Profile at Main Level MPEG Refers to standards developed by t...

Страница 131: ...mulated over a designated period Rating Region Table RRT Defines the TV parental guideline rating information system referenced by any content advisory descriptor carried within the Transport Stream SMPTE Society of Motion Picture and Television Engineers Standard Definition Television SDTV Signifies a digital television system in which the quality is approximately equivalent to that of NTSC This ...

Страница 132: ... Glossary Virtual Channel Table VCT Contains a list of all the channels that are or will be on line plus their attributes Among the attributes we have the channel name navigation identifiers stream components and types etc Information was taken from ATSC A65 and other ATSC and DVB standards ...

Страница 133: ...low 9 ACO6800 ISCST back module 6 cross functional parameter changes 85 features 2 packing list 12 parameters 85 98 ASI 95 96 SDI 87 94 subdevice 96 98 signal flow 10 ACO6800 ISD alarms 43 46 back module 6 control 35 46 features 1 LEDs 41 43 packing list 12 parameters 36 38 subdevice 39 40 signal flow 8 Alarm control switching using 24 Alarms ACO6800 DSD 55 subdevice 55 ACO6800 IDSD 67 subdevice 6...

Страница 134: ... file format 28 32 MicroSD card 32 Module status LEDs ACO6800 ASID 79 ACO6800 DSD 54 ACO6800 IDSD 66 ACO6800 ISCST 101 ACO6800 ISD 43 Modules back description 6 front description 4 N Navigator 17 O On screen display OSD activating 19 P Packing list 12 Parameter settings cautions 16 changing using card edge controls 18 20 using CCS applications 17 18 On screen display OSD 19 resetting to factory de...

Страница 135: ...andards RoHS compliance x WEEE compliance x Still image switching to 26 Streaming 21 Switching failure 24 Switching configuration 22 T Temperature specification 110 Thumbnails 21 Trouble slides 27 33 as still image source 27 creating 27 Troubleshooting discovery failure 112 installation 112 local control 112 not ready status 112 power failure causes communication problems 112 remote control 112 U ...

Страница 136: ...122 ACO6800 Installation and Operation Manual Copyright 2009 Harris Corporation Index ...

Отзывы: