background image

5718 52nd Street Kenosha WI 53144 | Orders and Customer Care: 1-866-616-1270 | Fax: 1-866-616-1271 | HarrisPoolProducts.com 

7.  Depress and turn the handle to the RINSE position.  

  In  the  RINSE  water  flow  is  directed  through  the  

  filter bed and out of the filter through the backwash  

  outlet. This process settles the filter media bed into  

  place and ensures any dirt or debris is rinsed out of  

  the filter, preventing possible return to the pool.

8.  Switch on the Pump. Open the Inlet Valve. Rinse  

  water will flow out through the drain pipe.

9.  When  the  rinse  water  in  the  sight  glass  appears  

  clear. Switch off the Pump. Close the Inlet Valve.

10. Depress and turn the handle to the Filter position  

  and Switch on the Pump. Open the Inlet Valve for  

  normal operation.

CHAPTER 7

: MAINTENANCE

The filter media will only require replacement once it 

has reached the limits of its designated life. Refer to 

the  product  information  of  the  particular  filter  media 

used. To ensure the maximum life of the selected filter 

media, please follow the procedures below.

1.  Backwash  the  filter  regularly  according  to  the  

  instructions set under BACKWASHING.

2.  Maintain a correct chemical balance for your pool  

  or spa’s water. The chemical balance of the water  

  is  a  relationship  between  its  pH,  Total  Alkalinity,  

  Calcium  Hardness  and  water  temperature.  The  

  water must be maintained to the following:

    -  pH Level: 7.2-7.8.

    -  Total Alkalinity: 80-175ppm

    -  Calcium Hardness: 175-300ppm

CHAPTER 8

: TROUBLESHOOTING

Above  normal  or  excessive  force  to  operate  the 

Multiport  Valve

:  Scoring  or  jamming  with  foreign 

matter or debris. If this condition persists after rinsing, 

disassemble  the  valve  to  clear.  Continued  operation 

of  the  valve  may  result  in  a  non-sealing  condition 

(damage to spider gasket). This will lead to water loss 

to the backwash line or to inefficient filtration. 

Dirty Water

1.  Insufficient filtration time.

2.  Heavy contaminants or dirt load.

3.  Dirty filter, requires backwashing.

4.  Air leaking on suction (influent line).

5.  Pump impeller vanes blocked.

6.  Insufficient water supply (water level low, blockage).

7.  Pump not primed.

8.  Incorrect water chemistry.

9.  Excessive  flow  of  water  for  filter  size.  Foreign  

  matter  or  debris  forced  through  filter  bed  and  

  through the underdrain. 

Filter Media in the backwash

1.  Excessive quantity of media in the filter.

2.  Excessive water flow.

3.  Incorrect size or grade of filter media.

Filter Media returning to Swimming Pool or Spa

1.  Filter is on recirculate.

2.  Verify  it  is  the  filter  media  and  not  from  another  

  source. 

3.  Damage to the underdrain laterals.

4.  Damage  or  incorrect  fit  of  Multiport  Valve  are  

  correct. 

5.  Incorrect or mixed grades of media in the filter.

Short filtration cycles

1.  Presence of algae or scale builds up.

2.  Check water chemistry.

3.  Excessive  water  flow,  check  pump  size,  mains  

  water flow.

4.  Filter blockage. Clean filter media.

CHAPTER 9

: SPECIFICATIONS

 ITEM  FLOW  MAXIMUM  FILTER  MEDIA

  NO.  RATE  PRESSURE  AREA REQUIRED

   GPM  PSI 

FT  LBS

 156593 

40 

50 

1.25 

100

 156594 

49 

50 

2.00 

175

 156595 

50 

50 

2.80 

300

Содержание 156593

Страница 1: ...nces Improper installation can create hazards which could result in property damage serious injury or death Improper installation will void the warranty The NOTICE label indicates special instructions that are important but not related to hazards Notice to Installer This manual contains important information about the installation operation and safe use of this product Once installation is complet...

Страница 2: ...nstalled and serviced only by a qualified professional 1 Position the filter next to the Swimming Pool or Spa 2 The filter should be placed on a level concrete slab very firm ground or equivalent Ensure that the ground will not subside preventing any strain from the attached plumbing 3 Position the filter so that the piping connections Multi Port Valve and winter drain is convenient and accessible...

Страница 3: ...to the Multiport Valve 8 Glue the plumbing to the Barrel unions and allow 24 hours for glue solvent to set before starting the filter 9 Test the filter and check for leaks around the threads If leaking occurs disconnect plumbing and repeat the steps 2 to 6 until the leak has stopped CHAPTER 4 INITIAL STARTUP OF FILTER Be sure correct amount of filter media is in tank and that all connections have ...

Страница 4: ...ate the deposited particles from filter media grains and flush them from the filter bed Backwashing is achieved by reversing the flow of water through the filter bed at a fairly high flow rate This high flow rate expands the filter bed and the water collects the debris taking it to waste Conditions for Backwashing Time for backwashing is determined by the following conditions 1 The flow rate throu...

Страница 5: ...ppm Calcium Hardness 175 300ppm CHAPTER 8 TROUBLESHOOTING Above normal or excessive force to operate the Multiport Valve Scoring or jamming with foreign matter or debris If this condition persists after rinsing disassemble the valve to clear Continued operation of the valve may result in a non sealing condition damage to spider gasket This will lead to water loss to the backwash line or to ineffic...

Страница 6: ...6173 Air Release Assembly for 156595 1 6a 647304008 Filter Tank for 156593 1 6b 647305008 Filter Tank for 156594 1 6c 647306008 Filter Tank for 156595 1 7 647304072 Flange Clamp 1 8 65431012080 O Ring 1 9 647304071 6 Way Valve 1 10 65431021080 O Ring 3 11 647303014 Hose Adapter 3 12 65021005000 Hose Clamp 2 13 647201802001 Adaptor 1 14a 647202772 PVC Hose for 156593 1 14b 647202871 PVC Hose for 15...

Отзывы: