Harrie Leenders DORAN Скачать руководство пользователя страница 11

Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance 

11

 

Periods of Prolonged Non­Use

 

If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to 
remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce con­ 
densation and subsequent damage, leave the air controls fully open.

 

Extractor fan

 

There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit 
smoke and fumes into the room.

 

Aerosol sprays

 

Do not use an aerosol spray on or near the stove when it is alight.

 

Use of operating tools

 

Always use the operating tools provided when handling parts likely to be hot when the stove is in use.

 

Chimney Fires

 

If the chimney is thoroughly and regularly swept, chimney fires should not occur.  However, if a chimney fire 
does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly 
close the doors of the stove.  This should cause the chimney fire to go out. If the chimney fire does not go 
out when the above action is taken then the fire brigade should be called immediately. Do not relight the 
stove until the chimney and flueways have been cleaned and examined by a professional.

 

Permanent air vent

 

The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. 
In accordance with current Building Regulations the installer may have fitted a permanent air supply vent 
into the room in which the stove is installed to provide combustion air. This air vent should not under any 
circumstances be shut off or sealed. 

USER OPERATING INSTRUCTIONS

 

Recommended fuels

 

Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the main 
stove manuals.

 

HETAS Ltd Approval

 

HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Approval 
does not cover the use of other fuels either alone or mixed with the recommended fuel, nor does it cover 
instructions for the use of other fuels.

Содержание DORAN

Страница 1: ...Harrie Leenders Doran Instructions for Installation Use and Maintenance 1 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE DORAN...

Страница 2: ...Harrie Leenders Doran Instructions for Installation Use and Maintenance 2...

Страница 3: ...hould know about the Doran 9 The three basic rules for proper burning 9 Warning note 10 Important notes 10 User operating instructions 11 The fine heat from wood 12 Initial fire up a good start 12 Ini...

Страница 4: ...structions for Installation Use and Maintenance 4 1 Flue pipe 2 Rotatable combustion chamber 3 Glass door 4 Combustion chamber door 5 Combustion chamber door handle 6 Storage compartment door knob 7 S...

Страница 5: ...owing Harrie Leenders Haardkachels Industrieweg 25 5688 DP Oirschot Nederland herewith declare that the product Doran is in conformity with the provisions of the following EC Directives when installed...

Страница 6: ...petent Persons can be found on their website at www hetas co uk CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a...

Страница 7: ...be clear of obstruction and have been swept clean immediately before installa tion of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after instal...

Страница 8: ...ion of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Connection to chimney Stoves may have a...

Страница 9: ...are subject to the greatest impacts being hit by wood when loading the fireplace and so have been additionally reinforced The air control slide controls the primary air flow over the fire and keeps t...

Страница 10: ...free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alarm...

Страница 11: ...supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade shou...

Страница 12: ...w times do not make your fire too hot because otherwise the bricks could crack You need not worry about any shrinkage cracks The initial fire up requires some additional time and attention as well as...

Страница 13: ...an evaporate Some liquid might come free from the ceramic fire brick Therefore place an old towel underneath the stove before firing up 5 After an hour you will start bringing the entire stove to the...

Страница 14: ...le bit until it is burning properly 5 A quietly burning fire is obtained by closing the air slide even more by pushing it inwards This will reduce the draught in the Doran For a glowing mass of charco...

Страница 15: ...fire always on a bed of ash This is an insulating layer for the fire and an excellent bed for the fuel If the Doran is overloaded with too much wood and the maximum amount of oxygen is supplied which...

Страница 16: ...Thicker deposits These can be treated with special fireplace glass cleaner this can also be done with a piece of moist paper towel and white ash Allow a moment for this to have its effect Always make...

Страница 17: ...tle and pull it towards the front You can then take it out easily 2 Lift the steel deflector a little and push it towards the back You can then take it out easily 3 Put a newspaper on the bottom of th...

Страница 18: ...s installed if you do not use a wall or stove base air supply system The stove is not suitable for a shared flue system Ensure adequate access for cleaning the appliance the flue gas connection and th...

Страница 19: ...the Doran has been tested by the manufacturers on a 3m straight flue Safety recommendations Glass tends to break easily and broken glass is quite sharp Therefore take adequate safety precautions For...

Страница 20: ...sh the loose bolts out of the pallet 2 Moving the stove Put a cushion or blanket between the sack truck and the stove Place the stove on the sacktruck its left side resting against the sack truck Caut...

Страница 21: ...he lower transport lock bolts Open the small door in the base Remove the red bolts open end spanner Loosen the green bolts up to the stop then secure them open end spanner 7 Release the upper transpor...

Страница 22: ...tove with top outlet The fasteners at the top become accessible by turning the top plate carefully to the left and then to the right without damaging the paint The fasteners at the bottom become acces...

Страница 23: ...t the bottom become accessible by turning the stove Fix the front panel using 4 countersunk M6 screws no 1 Use the four adjusting screws no 2 to adjust the height of the front panel so as to be equal...

Страница 24: ...Harrie Leenders Doran Instructions for Installation Use and Maintenance 24...

Страница 25: ...Harrie Leenders Doran Instructions for Installation Use and Maintenance 25...

Страница 26: ...Instructions for Installation Use and Maintenance 26 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www r...

Отзывы: