Harnisch+Rieth G-F 316 E Скачать руководство пользователя страница 7

6

G-F 316 E - 24.02.2002 / Vers.: 2

3.4  Changing the carbide metal milling tool

See Fig. 2., page 6)

1.  Switch off unit at main switch and pull mains supply plug.
2.  Take out the two recessed countersunk head screws (27) and take off the work table (16).
3.  With the milling tool (6) clamped in clean the swivel nut (22) with a brush.

Caution

The swivel nut must be cleaned before changing the milling tool as dust falling into the collet
chuck could cause damages to it.
The denture model grinding unit should not be cleaned with compressed air.

4.  Take the plastic plug out of the opening (23).
5.  Press the blocking pin (24) into opening (23) and turn the milling tool (6) until the blocking pin

(24) snaps in securely into the spindle thus locking it. The O-ring (25) prevents the blocking pin
from jumping out.

6.  Loosen the swivel nut (22) with the tubular hexagon box wrench (19 mm) (19) and using the

crossbar (26) and pull out the milling tool (6).

7.  Insert new milling tool (6) with O-ring (20).
8.  Slightly tighten the swivel nut (22) by hand until the milling tool shaft can just about be moved in

and out..

9.  Press down the milling tool (6), thus slightly squeezing the O-ring (20) and making it tight.. The

milling tool must be kept in this pressed position.

10.  Tighten the swivel nut (22) securely with the tubular hexagon box wrench (19).
11.  Pull out the blocking pin (24), seal opening (23) with the plastic plug and screw on the work

table  (16) again with the two recessed countersunk head screws (27).

Fig. 2: Front right view and front cross section

6 Milling tool

23 Opening for plastic plug

16 Work table

24 Blocking pin

19 Tubular hexagon box wrench (19 mm)

25 O-ring on the blocking pin

20 O-ring on the milling tool shaft

26 Crossbar Ø 12 mm

21 Suction channel

27 2 recessed countersunk head screws

22 Swivel nut (19 mm)

Содержание G-F 316 E

Страница 1: ...Operating instructions Machine designation Denture model grinding unit with Suction and filter unit Machine type G F 316 E Machine no Keep for future reference...

Страница 2: ...of operation 2 1 5 Marking of safety references contained in these instructions 2 2 Initial Setting into operation 3 2 1 Unpacking the unit 3 2 2 Identification of the unit components 3 2 3 Initial se...

Страница 3: ...re not damaged Before maintenance work and cleaning the unit should be switched off and disconnected from the mains supply i e the mains plug should be pulled Before accessing any of the incorporated...

Страница 4: ...lling spindle with collet chuck and conical carbide metal milling tool other milling tools upon request b Incorporated suction and filter unit consisting of a noise absorbing motor driven suction blow...

Страница 5: ...n running Note Press the denture slightly with both hands against the rotating milling tool 6 moving in opposite direction to the cutting direction 2 4 Checking the filter unit See Fig 1 page3 1 Switc...

Страница 6: ...1 Cleaning the suction channel 4 Insert new filter bag 3 tightly for further details see section 2 4 Checking the filter unit Note Also read section 3 3 Changing cleaning dry the ultra fine filter car...

Страница 7: ...Loosen the swivel nut 22 with the tubular hexagon box wrench 19 mm 19 and using the crossbar 26 and pull out the milling tool 6 7 Insert new milling tool 6 with O ring 20 8 Slightly tighten the swivel...

Страница 8: ...d with a spatula or a brush 1 Switch the unit off at the main switch and pull the mains supply plug 2 Take out the two recessed countersunk head screws 27 and take off the work table 16 3 Check and if...

Страница 9: ...type G F 316 E Overall dimensions Width 180 mm depth 520 mm Height 280 mm Electrical connection 230 volts 50 Hz Overvoltage category II Use category U S G and C Power consumption approx 700 watts Elec...

Страница 10: ...nsion of the original guaranty period Normal wear and tear or damages resulting from incorrect operation are not covered by the terms of warranty In order to be able to provide you with a comprehensiv...

Страница 11: ...9 GSG regulation of 12 05 93 EC low voltage directive 73 23 EEC corresponding to 1 GSG regulation of 11 06 79 EC EMC directive 89 336 EEC corresponding to EMC law of 09 11 92 Following harmonizing sta...

Отзывы: