SYMPTOM

 

POSSIBLE CAUSE

 

CHECK

 

 

 

 

   

 

 

 

 

 

 

NO POWER

 

-Incoming power to 
the pump?

 

 

 

 

 

-Is circuit breaker on?

  

 

 
PUMP 
DOES 
NOT  
TURN  
ON

 

-Is GFCL operating 
properly? 
 
-Is the air switch 
plugged in?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-Is the air switch hose 
connected to the

 

 

 

 

AIR SWITCH DISCONNECTED

 

 

 

pump?

 

 

 

 

 

 

 

 

  

-Is the air switch hose 
connected to the

 

 

 

 

  

 

actuator button on 
the tub deck?

 

 

 

 

   

 

 

 

 

PUMP 
NOT 
PUMPING 
PROPERLY

 

BLOCKAGE  OR LEAK 

 

 
-Jets should be 
pointed away from 
the suction inlet so air 
is not forced into 
pump suction.

 

 
-Is  the  in tub  suction  
inlet blocked

 

or covered? 
 
-Is  there  any debris  
in  the pump 
housing? 
 
-Is  there a  leak in  
the piping  or the 
Pump?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

VOLTAGE

 

-Is  the proper  
voltage applied  to 
the

 

 

 

 

 

pump?

 

 

 

 

 

-Is there an extension 
cord being used?

 

 

 

 

   

 

 

 

 

Содержание ZFPX5200

Страница 1: ...Imported by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www harmopool eu Manual Harmopool Whirlpool Bath Pump ZFPX5200 ZFPX5210 ZFPX5220 ...

Страница 2: ...Table of content Safety instructions 3 General information 3 Installation 4 Assembly 4 Electricity 4 Controls prior to first start up 5 Start up 5 Maintenance 5 FAQ 6 Appendices 7 ...

Страница 3: ...installed bath tub it is not suitable for swimming pool spa Do not install within an outer enclosure or beneath the skirt of a hot tub unless it has been marked This appliance is not intended to be used by young children or infirm persons unless they are being adequately supervised by a responsible person which can ensure their safety Young children are not allowed to play with the appliance FOR I...

Страница 4: ...5MPa The suction pipes should have a diameter equal to or larger than the discharge pipes This can avoid the heat loss and improve the efficiency The suction and discharge pipes should not rest on the pump Seal all the connectors and unions well Avoid any dripping on the motor This can unfailingly damage it Use the hose module which supplements along with the bathtub the old hose module cannot be ...

Страница 5: ...lem in the table of most common faults and their possible solutions FAQ that is provided on page 6 Start up Start the pump only when the suction and discharge pipes are connected to the corresponding inlets and outlets Apply voltage to the motor and suitably adjust the jets to obtain the desired flow Maintenance The pumps do not require any special maintenance or programming If the pump will be id...

Страница 6: ...ED pump Is the air switch hose connected to the actuator button on the tub deck PUMP NOT PUMPING PROPERLY BLOCKAGE OR LEAK Jets should be pointed away from the suction inlet so air is not forced into pump suction Is the in tub suction inlet blocked or covered Is there any debris in the pump housing Is there a leak in the piping or the Pump LOW VOLTAGE Is the proper voltage applied to the pump Is t...

Страница 7: ...ain and minimum water level Figure 2 Measurements and technical specifications Model Kracht P1 A B C D E F L H H1 H2 kW HP ZFPX5200 0 25 0 35 100 152 5 80 164 32 5 89 317 183 168 63 ZFPX5210 0 37 0 50 ZFPX5220 0 55 0 75 112 152 5 90 175 43 5 86 350 205 178 74 ...

Страница 8: ...8 Figuur 3 Performance curves Model Zwembad BVBA internal code JA35 ZFPX5200 JA50 ZFPX5210 JA75 ZFPX5220 ...