4
Installation
○
The pumps have to be installed horizontally. Pump must be fixed by screws on the tub shelf. and fixed
with silent block to lower the noise and liberation.
○
The pipe from and to the pool should be as short as possible.
○
The rating label should be visible after installation.
○
Parts containing electricity, except parts supplied with an extra low voltage <12V, must be inaccessible
to the person in the bath.
○
Class I appliances must be permanently connected to fixed wiring. Parts including electrical components,
except remote control devices, must be located or fixed so that they cannot touch the water.
Assembly
○
The diameter of the suction pipes should be larger or equal to the diameter of draining pipes.
○
The pipes are not allowed to lay on top off the pump.
○
Seal all the connectors and unions well. Avoid any dripping on the motor. This can unfailingly damage it.
Electrical installation
○
The electrical install action should have a multiple separation system with contact openings of at least
3mm.
○
For protection against possible electric shock this unit must be mounted to the base in accordance with
the installation instructions.
○
The protection of the system should be based on a residual current device (RCD) with a rated tripping
current not exceeding 30mA. The supply cable should comply with EMC standards.
○
Single-phase motors have built-in thermal protection.
○
The electric connection must be carried out by qualified staff following th "EN60335-2-60" standard
strictly.
○
Please ensure that the earth cable connection is correctly made.
○
Wires serving as equipotential bonding conductors must have a cross sectional area between 2.5 mm2
and 6 mm2 and must be equipped with the terminal suitable receptacle.
Controls prior to first start-up
○
Verify that the pump shaft turns freely.
○
Check whether the voltage and frequency are according to the name plate.
○
The Hydro massage assembly should be equipped with a system to prevent the pump from starting up
if a minimum water level is not present.
○
Check the rotating direction of the motor. This should correspond with the direction indicated on the
fan cover.
○
If the motor does not start up, try to locate the problem in the table of most common faults and their
possible solutions (FAQ).
○
NEVER LET THE PUMP RUN DRY