background image

 

 

 

 
 

 

Installation 

 

 

The pumps have to be installed horizontally. Pump must be fixed by screws on the tub shelf. and fixed 
with silent block to lower the noise and liberation.  

 

The pipe from and to the pool should be as short as possible. 

 

The rating label should be visible after installation. 

 

Parts containing electricity,  except parts supplied with an extra low voltage <12V, must be inaccessible 
to the person in the bath. 

 

Class I appliances must be permanently connected to fixed wiring. Parts including electrical components, 
except remote control devices, must be located or fixed so that they cannot touch the water. 

Assembly 

 

 

The diameter of the suction pipes should be larger or equal to the diameter of draining pipes.  

 

The pipes are not allowed to lay on top off the pump. 

 

Seal all the connectors and unions well. Avoid any dripping on the motor. This can unfailingly damage it. 

 

Electrical installation 

 

 

The electrical install action should have a multiple separation system with contact  openings of at least 
3mm. 

 

For protection against possible electric shock this unit must be mounted to the base in accordance with 
the installation instructions. 

 

The protection of the system should be based on a residual current device (RCD) with a rated tripping 
current not exceeding 30mA. The supply cable should comply with EMC standards.  

 

Single-phase motors have built-in thermal protection.  

 

The electric connection  must be carried out by qualified staff following th  "EN60335-2-60" standard 
strictly. 

 

Please ensure that the earth cable connection is correctly made. 

 

Wires serving as equipotential bonding conductors must have a cross sectional area between 2.5 mm2 
and 6 mm2 and must be equipped with the terminal suitable receptacle. 
 

Controls prior to first start-up

 

 

 

Verify  that  the pump  shaft  turns freely. 

 

Check  whether the voltage and frequency  are  according to  the  name plate. 

 

The Hydro massage assembly should be equipped with a system to prevent the  pump  from starting  up  
if a  minimum  water level  is  not present. 

 

Check the rotating direction of the motor. This should correspond with the direction indicated on  the 
fan cover. 

 

If the motor does not start up, try to locate the problem in the table of most common faults and their 
possible solutions (FAQ). 

 

NEVER LET THE PUMP RUN DRY 

 

 
 
 
 

 