13
Features and Specifications
Back Panel
Note:
The cabling of the JTAG connector of the service port shall use
min. 18AGW copper UL listed wiring.
Power Supply
AC Power Supply
The power supply supports 110 and 230 VAC, and automatically senses
the required voltage. A fuse is located inside the power socket and a
spare is located inside the adjacent compartment. For information about
replacing the fuse, see
Appendix A, “Fuse Replacement,”
“Connecting the AC Power Cable” on page 23
connect the power supply.
The following table lists the power supply specifications.
–48 VDC Power Supply
If your NSG has the optional –48 VDC power supply, the standard AC
power connector is replaced by a panel with a 3-pin male connector for
–48 VDC. This power supply does not have a fuse.
for instructions to wire the power
supply.
The NSG’s electrical rating for the -48VDC type is as follows:
Parameter
Specification
Input voltage
100–240 VAC
Line frequency
60–50 Hz
Typical power
consumption
154 W