Chapter 8 Hardware Reference
© 2017 Harmonic Inc. All rights reserved.
238
Harmonic MediaGrid Release 4.1
ContentServer 3000
Power Supply LEDs
and
describe the Power Supply Indicator/Handle and its functions.
.
Figure 8–18: Power Supply LEDs
Table 8–17: Power Supply Indicator Pattern
ContentServer 3000
The ContentServer 3000 presents data to clients, managing the actual data on the hard drives.
Front Panel Components
Front Bezel
Figure 8–19
and
describe the front bezel components of the ContentServer 3000.
Indicator Pattern
Condition
Not lit
AC power is not connected.
Steady green
A valid power source is connected to the power supply and the
power supply is operational.
Blinks green (1Hz)
AC power is connected but operating in a cold redundant state.
Blinks green (2Hz)
Power supply firmware is updating.
Blinks amber
A problem with the power supply has occurred but the power
supply is still functional.
CAUTION
:
If two power supplies are used, they must be of the
same type and have the same maximum output power.
Steady amber
A power supply failure has occurred, causing it to shut down.
Power Supply Status Indicator