    SAFETY GUIDE 

For RSF-B mini series 

Read this manual thoroughly before designing the application, installation, maintenance or inspection of the actuator. 

 

Indicates a potentially hazardous situation, 
which, if not avoided, could result in death 
or serious personal injury. 

Indicates a potentially hazardous situation, which, if 
not avoided, may result in minor or moderate personal 
injury and/or damage to the equipment. 

LIMITATION

 

OF

 

APPLICATIONS

 

The equipment listed in this document may not be used for the applications listed below: 

 

Space equipment 

 

Amusement equipment 

 

Aircraft, aeronautic equipment 

 

Machine or devices acting directly on the human body 

 

Nuclear equipment 

 

Instruments or devices to transport or carry people 

 

Household apparatus 

 

Apparatus or devices used in special environments 

 

Vacuum equipment 

 

Instruments or devices to prevent explosion 

 

Automobile, automotive parts 

 

Safety measures are essential for safe operation. 

Precautions when using a direct drive motor 

 

CAUTIONS FOR ACTUATORS AT THE APPLICATION DESIGN PHASE 

 

Always use under followings conditions: 

 The motor is designed to be used for indoor. 

-  Ambient temperature: 0

°

C to 40

°

-  Ambient humidity: 20% to 80%RH (Non-condensation) 
-  Vibration: 

24.5m/s

2  

-  No contamination by water, oil 
-  No corrosive or

 

explosive gas

 

 

Follow exactly the instructions to install the actuator 
in the equipment. 

 Ensure exact alignment of motor shaft center and 

corresponding center in the application. 

 Failure to observe this caution may lead to vibration, 

resulting in damage of output shaft.

 

 

CAUTION FOR ACTUATOR IN OPERATION 

 

Keep limited torques of the actuator.

 

 Keep limited torques of the actuator. 

 Be aware to balance the gravity for load mounting to 

output shaft.

 

 

Never connect cables directly to a power supply 
socket. 

 Direct drive motor cannot be operated unless it is 

connected to dedicated driver. 

 Never connect it to commercial power supply directly. 

Direct drive motor may be damaged and causes fire.

 

 

Do not apply shocks to actuator.

 

 

Do not apply shocks because direct drive motor is 
directly connected to high precision encoder. 

 If the encoder is damaged, it may cause uncontrollable 

operation.

 

 

Avoid handling of motor by cables. 

 Failure to observe this caution may damage the wiring, 

causing uncontrollable or faulty operation of direct drive 
motor.

 

 

Precautions when using a driver 

 

CAUTIONS FOR DRIVERS AT APPLICATION DESIGN PHASE 

 

Always use drivers under followings conditions: 

 Mount in a vertical position keeping sufficient distance 

to other devices to let heat generated by the driver 
radiate freely. 

-  Ambient temperature: 0

°

C to 50

°

-  Ambient humidity: less than 90% RH (Non 

condensation) 

-  No vibration or shocks 
-  No dust, dirt, corrosive, inflammable or explosive gas

 

 

Use sufficient noise suppressing means and safe 
grounding. 

 Keep signal and power leads separated. 

-  Keep leads as short as possible. 
-  Ground actuator and driver at one single point, minimum 

ground resistance class: D (less than 100 ohms) 

-  Do not use a power line filter in the motor circuit.

 

 

Pay attention to negative torque by inverse load. 

 Inverse load may cause damages of direct drive motor. 

 Please consult our sales office, if you intend to apply 

products for inverse load. 

 

 

Use a fast-response type ground-fault detector 
designed for PWM inverters. 

 Do not use a time-delay-type ground-fault detector. 

 

CAUTION FOR DRIVERS IN OPERATIONS 

 

Never change wiring while power is active. 

 Make sure of power non-active before servicing the 

products. 

 Failure to observe this caution may result in electric 

shock or personal injury.

   

 

Do not touch terminals at least 5 minutes after 
turning OFF power

 Otherwise, residual electric charges may result in electric 

shock. Wait for 5 min or more before inspection. 

 Make installation of products not easy to touch their inner 

electric components. 

 

 

Do not make a voltage resistance test   

 Failure to observe this caution may result in damage of 

the control unit. 

 Please consult our sales office, if you intend to make a 

voltage resistance test.

 

 

Do not operate control units by means of power 
ON/OFF switching. 

 Frequent power ON/OFF may result in deterioration of 

internal circuit elements. 

 Start/stop operation of direct drive motor should be 

performed via input signals. 

 

DISPOSAL OF DIRECT DRIVE MOTOR, A MOTOR, A CONTROL UNIT AND/OR THEIR PARTS 

 

All products or parts should be disposed of as industrial waste. 

 Since the case or the box of drivers have a material indication, classify parts and dispose them separately. 

 

CAUTION

 

CAUTION

 

CAUTION

 

WARNING

 

CAUTION

 

WARNING

 

CAUTION

 

CAUTION

 

WARNING

 

WARNING

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

WARNING

 

Содержание RSF B mini Series

Страница 1: ...iate safety measures when installing and operating the equipment Failure to do so may result in malfunction of the unit and personal injury Product specifications are subject to change without notice...

Страница 2: ...erve this caution may damage the wiring causing uncontrollable or faulty operation of direct drive motor Precautions when using a driver CAUTIONS FOR DRIVERS AT APPLICATION DESIGN PHASE Always use dri...

Страница 3: ...10 2 Radial load when the operating point is different 10 1 11 Rotary direction 11 1 12 Impact resistance 11 1 13 Vibration resistance 11 1 14 Torque speed characteristics 12 1 15 Cable specification...

Страница 4: ...RSF B mini series AC servo actuator manual contents 2 Memo...

Страница 5: ...zero backlash Harmonic Drive gear for precise motion control RSF B mini series actuators are ideal for robot joint drives semi conductor LCD panel manufacturing machine tools and other various types...

Страница 6: ...8B HA 680 4B 24 DCJ 055 09 DDP 090 09 DEP 090 09 RSF 11B HA 680 6B 24 DDP 090 36 DEP 090 36 RSF 14B HA 680 6B 24 DDP 090 36 DEP 090 36 RSF 8 B 30 F 100 24 B C SP Model AC servo actuator Design version...

Страница 7: ...Chapter 1 Overview of the RSF B mini series 3...

Страница 8: ...3 2 6 EMF constant V rpm 0 07 0 11 0 22 0 04 0 07 0 15 0 08 0 13 0 28 Phase resistance 20 0 93 0 19 0 26 Phase inductance mH 0 45 0 10 0 19 Moment of inertia N o t e GD2 4 kgm2 0 06 10 0 16 10 0 65 10...

Страница 9: ...wn as follows RSF 8B RSF 11B Note For detailed outside dimensions check the confirmation drawing Motor connector Pole sensor connector Encoder connector UL vinyl tube See the detailed drawing Motor co...

Страница 10: ...Chapter 1 Overview of the RSF B mini series 6 RSF 14B Note For detailed outside dimensions check the confirmation drawing Motor connector UL vinyl tube Pole sensor connector Encoder connector...

Страница 11: ...tuators are indicated in the table below Machine accuracy Unit mm A B C RSF 8B 0 04 0 04 0 03 RSF 11B 0 04 0 04 0 03 RSF 14B 0 04 0 04 0 03 Note Values by T I R Total Indicator Reading A Squareness of...

Страница 12: ...high rotational position accuracy Because of the gearing s high ratio any rotational error at the input i e motor shaft position error or motor feedback error is reduced by a factor of the ratio 1 ra...

Страница 13: ...rque region T1 T2 K3 spring rate for torque region over T2 The wind up for each region is expressed as follows wind up for torque region 0 T1 wind up for torque region T1 T2 wind up for torque region...

Страница 14: ...resolution per one rotation of the actuator output shaft is multiplied by gear ratio of the actual encoder resolution In addition the encoder signal is electrically multiplied by 4 The following tabl...

Страница 15: ...kgf 10 20 40 1 10 2 Radial load when the operating point is different If the operating point of radial load is different the allowable radial load value is also different The relation between radial l...

Страница 16: ...RSF 3A is also the same For details of the driver refer to AC Servo Driver HA 680 Series Technical Data 1 12 Impact resistance The impact resistance of the actuators is as follows Impact acceleration...

Страница 17: ...B 30 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 0 50 100 150 200 250 Speed r min Torque N m RSF 8B 50 0 0 5 1 1 5 2 2 5 3 3 5 0 20 40 60 80 100 120 140 Speed r min Torque N m 150X150X6 mm RSF 8B 100 0 1 2...

Страница 18: ...150X6 mm RSF 14B 30 0 1 2 3 4 5 6 7 8 9 10 0 50 100 150 200 250 Speed r min Torque N m RSF 14B 50 0 2 4 6 8 10 12 14 16 18 20 0 20 40 60 80 100 120 140 Speed r min Torque N m 150X150X6 mm RSF 14B 100...

Страница 19: ...E 5 6 Connector used Plug 350715 1 AMP Pin 350690 1 AMP Pole sensor connector cable Connector used Housing 51047 0800 Molex Terminal 50133 8000 Molex Encoder connector cable Connector used Housing 51...

Страница 20: ...nt immediately contact the dealer it was purchased from The model code is interpreted as follows For details of model symbols refer to 1 2 Models on page 2 3 The INPUT VOL line of the driver label ind...

Страница 21: ...n of the actuator Vibration 25 m sec2 10Hz 400Hz or less Impact 300 m sec2 or less Make sure the actuator is in an area free from dust water condensation metal powder corrosive gas water water drops a...

Страница 22: ...r for coupling installation 2 Fasten the flange of the actuator with flat washers and high strength bolts Use a torque wrench when tightening the fasteners The recommended tightening torque is shown i...

Страница 23: ...rs EWC MB A06 TN2 2 For motors EWA M JST04 TN2 For an incremental encoder pole sensor EWB F M0809 3M14 Cable length 03 3m 05 5m 10 10m Cable length 03 3m 05 5m 10 10m Clamp filter ZCAT2032 0930 TDK Cl...

Страница 24: ...ype CNK HA68 S2 For CN2 power supply connection 2 types Connector for actuator connection Mfg by Phoenix Contact Model MC1 5 6 ST 3 81 Or Mfg by Omron Model XW4B 06B1 H1 Connector for power supply Mfg...

Страница 25: ...nt 0 0167 5 08x10 3 0 3048 0 0254 Unit m min ft min ft s in s Coefficient 60 196 9 3 281 39 37 SI unit m s 3 Linear acceleration SI unit m s2 Unit m min2 ft min2 ft s2 in s2 Coefficient 2 78 x10 4 8 4...

Страница 26: ...nit Nm Unit kgfm lbft lbin ozin Coefficient 9 81 1 356 0 1130 7 06x10 3 Unit kgfm lbft lbin ozin Coefficient 0 102 0 738 8 85 141 6 SI unit Nm 10 Moment of inertia SI unit kgm2 Unit kgfms2 kgfcms2 lbf...

Страница 27: ...ss inertia position of center of gravity Circular cylinder Round pipe Tilted circular cylinder Sphere Elliptic circular cylinder Cone Prism Regular square pipe R L z x y L R m 2 2 R m 2 1 Ix 3 L R m 4...

Страница 28: ...alculated by the following formula I Moment of inertia when axis of center of gravity and axis of revolution do not match kgm2 Ig Moment of inertia when axis of center of gravity and axis of revolutio...

Страница 29: ...Shape Circular cylinder Outside diameter 100mm Since the outside diameter is 100mm the radius is 50mm Based on the top graph moment of inertia is about 1 9 x 10 4 kgm2 Calculated value 0 000186kgm2 Ra...

Страница 30: ...RSF B mini series AC servo actuator manual Memo...

Страница 31: ...RSF B mini series AC servo actuator manual Memo...

Страница 32: ...to 1 user s misapplication improper installation inadequate maintenance or misuse 2 disassembling modification or repair by others than Harmonic Drive Systems Inc 3 imperfection caused by the other t...

Страница 33: ...arlos Street Suite 1070 San Jose CA 95110 Chicago Sales Office 137 N Oak Park Ave Suite 410 Oak Park IL 60301 T 800 921 3332 T 978 532 1800 F 978 532 9406 www HarmonicDrive net Group Companies Harmoni...

Отзывы: