background image

 

 

SAFETY GUIDE 

For RSF-B mini series, HA series   

manufactured by Harmonic Drive Systems Inc   

Read this manual thoroughly before designing the application, installation, maintenance or inspection of the actuator. 

 

Indicates a potentially hazardous situation, 

which, if not avoided, could result in death 

or serious personal injury. 

Indicates a potentially hazardous situation, which, if 

not avoided, may result in minor or moderate personal 

injury and/or damage to the equipment. 

LIMITATION

 

OF

 

APPLICATIONS

 

The equipment listed in this document may not be used for the applications listed below: 

 

Space equipment 

 

Amusement equipment 

 

Aircraft, aeronautic equipment 

 

Machine or devices acting directly on the human body 

 

Nuclear equipment 

 

Instruments or devices to transport or carry people 

 

Household apparatus 

 

Apparatus or devices used in special environments 

 

Vacuum equipment 

 

Instruments or devices to prevent explosion 

 

Automobile, automotive parts 

 

Safety measures are essential to prevent accidents resulting in death, injury or damage of the equipment due to 

malfunction or faulty operation. 

Precautions when using a direct drive motor 

 

CAUTIONS FOR DIRECT DRIVE MOTOR AT APPLICATION DESIGNING 

 

Always use under followings conditions: 

 The motor is designed to be used for indoor. 

-  Ambient temperature: 0

°

C to 40

°

-  Ambient humidity: 20% to 80%RH (Non-condensation) 

-  Vibration: 

24.5m/s

以下

 

-  No contamination by water, oil 

-  No corrosive or

 

explosive gas

 

 

Follow exactly the instructions to install the actuator 

in the equipment. 

 Ensure exact alignment of motor shaft center and 

corresponding center in the application. 

 Failure to observe this caution may lead to vibration, 

resulting in damage of output shaft.

 

 

CAUTION FOR DIRECT DRIVE MOTOR IN OPERATIONS 

 

Keep limited torques of the actuator.

 

 Keep limited torques of the actuator. 

 Be aware to balance the gravity for load mounting to 

output shaft.

 

 

Never connect cables directly to a power supply 

socket. 

 Direct drive motor cannot be operated unless it is 

connected to dedicated driver. 

 Never connect it to commercial power supply directly. 

Direct drive motor may be damaged and causes fire.

 

 

Do not apply shocks to actuator.

 

 

Do not apply shocks because direct drive motor is 

directly connected to high precision encoder. 

 If the encoder is damaged, it may cause uncontrollable 

operation.

 

 

Avoid handling of motor by cables. 

 Failure to observe this caution may damage the wiring, 

causing uncontrollable or faulty operation of direct drive 

motor.

 

 

Precautions when using a driver 

 

CAUTIONS FOR DRIVERS AT APPLICATION DESIGNING 

 

Always use drivers under followings conditions: 

 Mount in a vertical position keeping sufficient distance 

to other devices to let heat generated by the driver 

radiate freely. 

-  Ambient temperature: 0

°

C to 50

°

-  Ambient humidity: less than 90% RH (Non 

condensation) 

-  No vibration or shocks 

-  No dust, dirt, corrosive, inflammable or explosive gas

 

 

Use sufficient noise suppressing means and safe 

grounding. 

 Keep signal and power leads separated. 

-  Keep leads as short as possible. 

-  Ground actuator and driver at one single point, minimum 

ground resistance class: D (less than 100 ohms) 

-  Do not use a power line filter in the motor circuit.

 

 

Pay attention to negative torque by inverse load. 

 Inverse load may cause damages of direct drive motor. 

 Please consult our sales office, if you intent to apply 

products for inverse load. 

 

 

Use a fast-response type ground-fault detector 

designed for PWM inverters. 

 Do not use a time-delay-type ground-fault detector. 

 

CAUTION FOR DRIVERS IN OPERATIONS 

 

Never change wiring while power is active. 

 Make sure of power non-active before servicing the 

products. 

 Failure to observe this caution may result in electric 

shock or personal injury.

   

 

Do not touch terminals at least 5 minutes after 

turning OFF power

 Otherwise, residual electric charges may result in electric 

shock. Wait for 5 min or more before inspection. 

 Make installation of products not easy to touch their inner 

electric components. 

 

 

Do not make a voltage resistance test or megger 

test. 

 Failure to observe this caution may result in damage of 

the control unit. 

 Please consult our sales office, if you intent to make a 

voltage resistance test.

 

 

Do not operate control units by means of power 

ON/OFF switching. 

 Frequent power ON/OFF may result in deterioration of 

internal circuit elements. 

 Start/stop operation of direct drive motor should be 

performed via input signals. 

 

DISPOSAL OF DIRECT DRIVE MOTOR, A MOTOR, A CONTROL UNIT AND/OR THEIR PARTS 

 

All products or parts have to be disposed of as industrial waste. 

 Since the case or the box of drivers have a material indication, classify parts and dispose them separately. 

 

SYSTEMS 

CAUTION

 

CAUTION

 

CAUTION

 

WARNING

 

CAUTION

 

WARNING

 

CAUTION

 

CAUTION

 

WARNING

 

WARNING

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

CAUTION

 

WARNING

 

Содержание RSF-11B

Страница 1: ...perating the equipment so as to prevent an accident resulting in a serious physical injury damaged by a malfunction or improper operation Product specifications are subject to change without notice fo...

Страница 2: ...ntrollable operation Avoid handling of motor by cables Failure to observe this caution may damage the wiring causing uncontrollable or faulty operation of direct drive motor Precautions when using a d...

Страница 3: ...and allowable thrust load 10 1 10 2 Radial load when the operating point is different 10 1 11 Rotary direction 11 1 12 Impact resistance 11 1 13 Vibration resistance 11 1 14 Torque speed characterist...

Страница 4: ...RSF B mini series AC servo actuator manual contents 2 Memo...

Страница 5: ...stics Small lightweight and high torque The RSF B mini series with the precision control deceleration device HarmonicDrive realizes a small lightweight high torque and has a very high output torque fo...

Страница 6: ...ratio of gearing 30 1 30 50 1 50 100 1 100 Motor power voltage specification 24 24V Encoder specifications E incremental encoder pole sensor Frame size 8 11 14 Resolution of the encoder 100 1000P rev...

Страница 7: ...21 4 1 6 7 15 7 8 13 27 MEF constant V r min 0 07 0 11 0 22 0 04 0 07 0 15 0 08 0 13 0 28 Phase resistance 20 0 93 0 19 0 26 Phase inductance mH 0 45 0 10 0 19 Moment of inertia N o t e GD 2 4 kgm 2...

Страница 8: ...n drawing issued by us Tolerances may vary due to product manufacturing method foundry piece machine finished good If necessary please contact us for the tolerance when it is not indicated in the dime...

Страница 9: ...e delivery specification drawing issued by us Tolerances may vary due to product manufacturing method foundry piece machine finished good If necessary please contact us for the tolerance when it is no...

Страница 10: ...tuators are indicated in the table below Machine accuracy Unit mm A B C RSF 8B 0 04 0 04 0 03 RSF 11B 0 04 0 04 0 03 RSF 14B 0 04 0 04 0 03 Note Values by T I R Total Indicator Reading A Squareness of...

Страница 11: ...4 7 27 10 4 5 82 10 4 7 27 10 4 5 82 10 4 Reference Accuracy display and measurement method according to JIS B 6201 1987 One way positioning of rotation shaft motion First perform positioning at any o...

Страница 12: ...que region T1 T2 K3 spring rate for torque region over T2 The wind up for each region is expressed as follows wind up for torque region 0 T1 wind up for torque region T1 T2 wind up for torque region o...

Страница 13: ...re the resolution per one rotation of the actuator output shaft is multiplied by gear ratio of the actual encoder resolution In addition the encoder signal is electrically multiplied by 4 The followin...

Страница 14: ...kgf 10 20 40 1 10 2 Radial load when the operating point is different If the operating point of radial load is different the allowable radial load value is also different The relation between radial l...

Страница 15: ...RSF 3A is also the same For details of the driver refer to AC Servo Driver HA 680 Series Technical Data 1 12 Impact resistance The impact resistance of the actuators is as follows Impact acceleration...

Страница 16: ...B 30 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 0 50 100 150 200 250 Speed r min Torque N m RSF 8B 50 0 0 5 1 1 5 2 2 5 3 3 5 0 20 40 60 80 100 120 140 Speed r min Torque N m 150X150X6 mm RSF 8B 100 0 1 2...

Страница 17: ...150X6 mm RSF 14B 30 0 1 2 3 4 5 6 7 8 9 10 0 50 100 150 200 250 Speed r min Torque N m RSF 14B 50 0 2 4 6 8 10 12 14 16 18 20 0 20 40 60 80 100 120 140 Speed r min Torque N m 150X150X6 mm RSF 14B 100...

Страница 18: ...GRN E 5 6 Connector used Plug 350715 1 AMP Pin 350690 1 AMP Pole sensor connector cable Connector used Housing 51047 0800 Molex Terminal 50133 8000 Molex Encoder connector cable Connector used Housin...

Страница 19: ...el symbols refer to 1 2 Models on page 2 3 The model code of the RSF B mini series actuator to be driven is indicated on the ADJUSTED FOR USE WITH line of the driver label Match the actuator with its...

Страница 20: ...of the actuator Vibration 25 m sec2 10Hz 400Hz or less Impact 300 m sec2 or less Make sure the actuator is in an area free from dust water condensation metal powder corrosive gas water water drops an...

Страница 21: ...he actuator with flat washers and high strength bolts Use a torque wrench when tightening the fasteners The recommended tightening torque is shown in the table below Model Item RSF 8B RSF 11B RSF 14B...

Страница 22: ...ing driver HA 680 series For motors EWC MB A06 TN2 2 For motors EWA M JST04 TN2 For an incremental encoder pole sensor EWB F M0809 3M14 Cable length 03 3m 05 5m 10 10m Cable length 03 3m 05 5m 10 10m...

Страница 23: ...ype CNK HA68 S2 For CN2 power supply connection 2 types Connector for actuator connection Mfg by Phoenix Contact Model MC1 5 6 ST 3 81 Or Mfg by Omron Model XW4B 06B1 H1 Connector for power supply Mfg...

Страница 24: ...s in s Coefficient 0 0167 5 08x10 3 0 3048 0 0254 Unit m min ft min ft s in s Coefficient 60 196 9 3 281 39 37 SI unit m s 3 Linear acceleration SI unit m s 2 Unit m min 2 ft min 2 ft s 2 in s 2 Coeff...

Страница 25: ...Nm Unit kgfm lbft lbin ozin Coefficient 9 81 1 356 0 1130 7 06x10 3 Unit kgfm lbft lbin ozin Coefficient 0 102 0 738 8 85 141 6 SI unit Nm 10 Moment of inertia SI unit kgm 2 Unit kgfms 2 kgfcms 2 lbft...

Страница 26: ...ss inertia position of center of gravity Circular cylinder Round pipe Tilted circular cylinder Sphere Elliptic circular cylinder Cone Prism Regular square pipe R L z x y L R m 2 2 R m 2 1 Ix 3 L R m 4...

Страница 27: ...alculated by the following formula I Moment of inertia when axis of center of gravity and axis of revolution do not match kgm2 Ig Moment of inertia when axis of center of gravity and axis of revolutio...

Страница 28: ...ape Circular cylinder Outside diameter 100mm Since the outside diameter is 100mm the radius is 50mm Based on the top graph moment of inertia is about 1 9 x 10 4 kgm 2 Calculated value 0 000186kgm2 Rad...

Страница 29: ...RSF B mini series AC servo actuator manual Memo...

Страница 30: ...RSF B mini series AC servo actuator manual Memo...

Страница 31: ...t that has been subject to 1 user s misapplication improper installation inadequate maintenance or misuse 2 disassembling modification or repair by others than Harmonic Drive Systems Inc 3 imperfectio...

Страница 32: ...rive AG Hoenbergstra e 14 65555 Limburg Germany TEL06431 5008 0 FAX06431 5008 18 Harmonic Drive L L C 247 Lynnfield Street Peabody MA 01960 U S A TEL 1 978 532 1800 FAX 1 978 532 9406 1703 6R TRSFB E...

Отзывы: