© 2018Harmar Mobility, LLC • All Rights Reserved
| www.harmar.com
12
Pinnacle SL300
INSTALLATION PROCEDURES
G. AUDIBLE TONES
If the lift does not operate, check the safety senors:
•
Seat swivel sensor (seat should be in the
locked position)
•
Footrest lower sensor (check by pushing in
on the safety pan on the footrest)
•
Upper foot pan safety sensor (check by
pushing on the safety pan on the footrest).
•
On folding rail model only-Uphill safety
sensor (ensure nothing is blocking upward
passage)
•
On folding rail model only-Downhill
safety sensor (ensure nothing is blocking
downward passage)
If the stairlift still does not operate after testing
sensors, turn the unit off and re-check all wire
H. TONES INFORMATION
Minor faults
Single long beep (will reset once fault is cleared)
•
Seat swiveled out of position
•
Edge safety detected
•
Current overload condition
•
A Low battery voltage condition
Pulsing Beep
Lift stopped off of charge strip. Will sound after
30 second for 30 seconds. It will repeat ever 10
minutes until lift is operated or returned to charge
strips.
Major Tones
Tones
Number of Beeps.
Runaway
1
No Power
2
Conflicting Switches Footrest UP & Footrest DOWN
3
*Conflicting Switches Obstruction UP & Obstruction DOWN
4
*Conflicting Switches Footrest DOWN & Obstruction UP
5
Conflicting Switches Footrest UP & Obstruction DOWN
6
Conflicting Switches STOP UP & STOP DOWN switches both Detected
7
Conflicting Switches STOP UP & STOP DOWN switches both NOT Detected
8
* If configured for your model.