background image

Harman®  •  XXV Installation Manual_R23  •  2004 -___  •  08/13

7

3-90-00684i

Clearances 

Figure 3.1

A. Appliance Dimension Diagram

Dimensions are actual appliance dimensions. Use for reference only.

31.119

28.406

29.429

4.041

12.417

8.623

14.715

28.584

26.725

24.323

Outside Air 

Intake

Содержание XXV Freestanding Pellet Stove

Страница 1: ...ng codes prior to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspec...

Страница 2: ...Non Combustible Materials Specification 4 F Combustible Materials Specification 4 G Electrical Codes 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies Needed 6 C Ins...

Страница 3: ...roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided to the...

Страница 4: ...listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without full...

Страница 5: ...vent termination CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufa...

Страница 6: ...ructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair...

Страница 7: ...2004 ___ 08 13 7 3 90 00684i 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference only 31 119 28 406 29 429 4 041 12 417 8 623 14 715 28 5...

Страница 8: ...tibles When selecting a location for the appliance it is important to consider the required clearances to walls see Figure 3 2 WARNING Risk of Fire or Burns Provide adequate clearance around air openi...

Страница 9: ...l Other floor protector materials are ceramic tile stone brick etc Mobile Home Installation When installing this unit in a mobile home several requirements must be followed Reference HUD Regulation 24...

Страница 10: ...ethod This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high a...

Страница 11: ...ting fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you...

Страница 12: ...vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 7 Installing into an...

Страница 13: ...ugh the ceiling Through the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through Seal pipe joints with silicone or aluminum tape in addition to the sealin...

Страница 14: ...y is fully open on a minimum of 2 sides beneath the floor NOTE where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Can...

Страница 15: ...hich the pellet appliance is located Consult with your local HVAC professional to determine the ventilation demands for your house C Venting Use of Elbows A combustion blower is used to extract the co...

Страница 16: ...e demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult wit...

Страница 17: ...g should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed F Draft Draft is the pressure difference needed to ven...

Страница 18: ...mends Installing the pellet vent with a minimum vertical run of five feet preferably terminating above the roof line Installing the outside air intake at least four feet below the vent termination To...

Страница 19: ...ny parts damaged in shipment Read all the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit Installation an...

Страница 20: ...guide on top of the burn pot Make sure that the flame guide is fully seated on the vertical sides of the burn pot and that the back of the guide rests against the body of the stove Figure 5 3 INSTALL...

Страница 21: ...his voltage adjustment allows the installer to change the low voltage set point approximately 10 volts This adjustment should be done by the installer during set up because a draft meter reading is re...

Страница 22: ...hey are in the same room as the stove Clothing and other flammable materials should not be placed on or near this stove Installation and repair of this stove should be done by a qualified service pers...

Страница 23: ...BLUE MALE FEMALE CONNECTIONS 1 3 2 WHITE PLUGGED BROWN 5 6 7 EMPTY WHITE WHITE WHITE 4 8 10 9 RED BLUE YELLOW PART NO 3 90 00877 BLACK 11 WHITE 11 PIN PLUG MALE FEMALE CONNECTIONS GREEN WIRE IS GROUN...

Страница 24: ...U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For...

Отзывы: