Harman TL300 Скачать руководство пользователя страница 7

Harman TL300

7

The Stove

doors

Your stove has a large glass-paneled door for loading 

and fire viewing, a separate smaller door for removing 

ashes, and a top loading door.  

Front door

Before opening, always check for wood, embers, or 

ash that may be ready to fall out of the door. 

To open the glass door, open bypass damper first, 

by pulling forward on the top load door handle, to the 

first position. Then lift up on the front door handle to 

disengage the latch, and pull out. To close the door, 

push door closed with handle in the open position, then 

push handle down to engage the latch.  

ash door

To open the ash door, open the bypass damper first. 

Lift up on the ash door handle and pull it open. Close 

the door by pushing in and pushing the handle all the 

way down. 

Top Load door

To open the top load door, pull forward on the top 

load door handle. The first position tells you the bypass 

damper is open. Continue pivoting the handle toward 

you until it locks the top load door open.

All doors must be closed while the stove is in normal 

operation, and the gaskets routinely examined for wear 

and  replaced  when  necessary.  Good  door  seals  are 

important for maintaining control of the stove. Never 

operate with the ash door open. Operating the stove with 

the ash door open, or with a door improperly sealed, 

could create a serious overfiring condition (discussed 

later in this section).

general considerations

draft

Before you install and/or operate your TL300 wood 

stove, please read the entire contents of this manual. 

Pay particular attention to the explanation of draft and its 

effect on stove performance, in the installation section. 

By following the installation and operating guidelines, 

you  will  ensure  proper  draft  and  gain  maximum 

efficiency and enjoyment from your stove.

Fuel

Your TL300  burns wood very efficiently.  Here are 

some  guidelines  concerning  log  size  and  moisture 

content that will help you obtain the best performance.

Select dry seasoned wood. For example, it should be 

checked or cracked on the ends and not exposed to rain 

or extremely damp conditions. Hardwoods are favored 

because  they  are  heavier  and  contain  more  heating 

capacity (BTU’s) per load than do softwoods.  Wood 

should be split and stored under cover for “seasoning” - 

a year is recommended.  Your stove is not an incinerator 

- do not burn garbage, painted or treated wood, plastics, 

or other debris.

Keep  the  area  around  the  stove  free  from  clutter.  

Keep all combustibles, including fuel, beyond the code-

required  clearance  distance  (48"  or  1215  mm  in  the 

U.S., 1525 mm or 60" in Canada).  Never store fuel 

in front of the stove where it could interfere with door 

operation, safe loading, and ash removal.

do  not  burn  garbage  or  flammable  fluids 

such as gasoline, naptha, or engine oil.

Specifications

never oPeraTe WiTh More Than one 

door oPen aT a TiMe.

The glass used in your TL300 is manufactured to 

exact standards to withstand the high heat of the 

fire, but like all glass, it must be treated with common 

sense and care.  Never abuse the  glass by slamming 

the door shut or striking the glass with a heavy object.  

If the glass is broken or damaged, do not operate the 

stove until it has been replaced (See instructions in 

Maintenance section.)

grates

 

The Harman TL300 has a unique grate system that 

consists of one bottom grate, and two front andirons.  

The bottom grate has slots which allow the ash to 

fall into the ash pan by passing a poker back and 

forth across the grate. The andirons keep the fuel 

from coming into direct contact with the glass, and 

keep hot coals and embers from spilling out while 

reloading. Never build a fire directly against the 

glass. Andiron extensions (included with each stove) 

clip onto the fixed andirons and serve to protect the 

glass when top loading is used as the primary load-

ing method. The grates and andirons must remain in 

place at all times. Do not tamper with or change the 

configuration of this grate system.

cauTion: 

always wear fire retardant gloves 

when operating the stove.

SaFeTY noTice

IF  THIS  HARMAN  TL300  STOVE  IS  NOT 

PROPERLY  INSTALLED,  OPERATED AND 

MAINTAINED, A  HOUSE  FIRE  MAY  RESULT. 

FOR YOUR SAFETY, FOLLOW  INSTALLATION  

DIRECTIONS.  CONTACT LOCAL BUILDING OR 

FIRE OFFICIALS ABOUT RESTRICTIONS AND 

INSTALLATION INSPECTION REQUIREMENTS 

IN YOUR AREA.

Содержание TL300

Страница 1: ...table for installation in a mobile home us only IF THIS wood burning STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FI...

Страница 2: ...2 Harman TL300...

Страница 3: ...e to follow instructions may result in property damage bodily injury or even death Index Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 U S A Introduction 4 Specifications 5 Ins...

Страница 4: ...50 mm 775mm 600 mm 450 mm 675 mm CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA CONSULTEX LES ADMINISTRATIONS ET ORGANISMES COMPETENTS POUR LA CON...

Страница 5: ...ax Heating Capacity 1 500 3 000 sq ft Average Emissions 1 1 Grams Per Hr Emissons on Low 0 8 Grams Per Hr Outside Air Size 3 or 4 Inch SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIR...

Страница 6: ...6 Harman TL300 Specifications Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch Top Load Door Top Load Opening...

Страница 7: ...ed to rain or extremely damp conditions Hardwoods are favored because they are heavier and contain more heating capacity BTU s per load than do softwoods Wood should be split and stored under cover fo...

Страница 8: ...U S and 60 1524 mm in Canada Due to excessive heat build up at the wall passthrough using double wall pipe horizontal venting is only approved into a masonry chimney See Detailed Clearances on Page 9...

Страница 9: ...vent vented out back wall with 90o elbow Masonry Chim ney Only 21 15 11 2 28 Top vent ceiling and sidewall clearances 28 17 Single Wall Pipe Top Vent Parallel Installation 20 Double Wall Pipe Parallel...

Страница 10: ...of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor or ceiling Whene...

Страница 11: ...point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Higher...

Страница 12: ...masonry chimney several provisions are standard First whether the chimney connector is vented to the chimney through a thimble or a breech pipe neither must pass beyond the inner surface of the chimn...

Страница 13: ...13 Harman TL300 Venting Standard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney...

Страница 14: ...inimum of three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Protection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breac...

Страница 15: ...bly 1 Clearance for Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clearance for NFPA 211 Type Approved Thimbles Floor Protecion in Accordance with Solid Fuel Appliance Listing Check with...

Страница 16: ...urned This represents most of the wood s heating capacity The final stage is the charcoal stage where the charcoal burns the remaining heat content out of the fuel Ash remains after the burning is com...

Страница 17: ...o not have the proper coal bed Open the bypass damper and continue with the process until a significant coal bed is formed To regulate the speed of the optional convection blower adjust the variable s...

Страница 18: ...until all cinders have thoroughly cooled This could take days Never use the ash disposal container for other trash Wood ash can be added to your garden or compost g Avoid overfiring your stove Overfi...

Страница 19: ...refractory lining material grates and casting If any bricks have been damaged replace them with Harman replacement parts Be sure that all air holes in the refractory are open The Firedome combustion p...

Страница 20: ...t the added ramp tension needed to keep the damper held in the closed position To adjust the ramp the stove MUST be allowed to go out and cool down After the stove has cooled off remove the stove pipe...

Страница 21: ...n outside air duct less than 5 1525 mm long may be 3 80mm in diameter and be made of masonry tile 26 gauge 0 019 galvanized steel or other approved noncombustible material it should have a 1 25 mm cle...

Страница 22: ...00 3 goldenfire ending Manufacturing date june 2011 1 90 06900 4 Metallic blue ending Manufacturing date jan 2010 beginning Manufacturing date aug 2007 ending Manufacturing date active 1 90 06900 1 bl...

Страница 23: ...2019 15 Top Load Door Gasket Plate 1 10 40020 Y Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y Nut Zinc Plated Acron Pkg of 50 3 30 8014 50 Y 8...

Страница 24: ...8 3 Damper Linkage Arm Weldment w Hardware 1 10 06937W Y 18 4 Damper Pivot Gear Pkg of 2 2 00 06924 2 18 5 Damper Idler Gear 2 00 06923L 18 6 Damper Arm Gear Weldment 1 10 06916W Y 18 7 Damper Shaft C...

Страница 25: ...ick Bracket Pkg of 2 1 00 06945 Y 19 7 Fire Brick 6 x 12 Qty 4 req Pre 551 4 40 86125 Y Post 551 3 40 86125 Y 19 8 Brick Insulation Qty 2 req 3 40 06944 Y 19 9 Grate 2 00 06925B Y 19 10 Inlet Brick Ri...

Страница 26: ...26 Harman TL300 This page intentionally left blank...

Страница 27: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 28: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 29: ...29 Harman TL300 Notes...

Страница 30: ...30 Harman TL300 Notes...

Страница 31: ......

Страница 32: ...Proudly Printed On 100 Recycled Paper...

Отзывы: