18.1
18.1: VM ² > HIQNET CONFIGURATION
18.1: VM ² > HIQNET CONFIGURATION
IP
Configuration
Range Low
Range High
Select either Dynamic
(DHCP) or Manual
(MAN) IP conifguration.
If you are using a DHCP server to automatically
configure the IP setup, wait for several seconds until an
IP address appears in the IP ADDRESS Vistonics control
fields. You will also see it on the far left of the HiQnet
page.
DHCP
Manual
IP Address
Entry
Set IP address for the
console.
For use with Manual (MAN) IP Configuration. Use the
row of VST encoders to dial-in the required IP address
for the console.
The available ranges of valid IP addresses are 10.0.0.0
- 10.255.255.255; 172.16.0.0 - 172.31.255.255;
192.168.0.0 - 192.168.255.255. Some IP addresses
within the ranges show are not allowed due to conflicts
with other parts of the Vi system – they will be greyed out
and not available for selection.
Subnet Mask
Entry
Set the subnet mask.
For use with Manual (MAN) IP Configuration. Use the
row of VST encoders to dial-in the subnet mask.
HiQnet node
address entry
Active
Set the console's
HiQnet Node
Address using the
keyboard editor on the
touchscreen.
The HiQnet node address can be any number in the
range 1 – 65,535 but it must be a unique number within
the network in order to avoid conflicts with other HPro
devices. You can use Audio Architect to find out what the
node addresses of other equipment are.
Note that it will take up to 10 seconds for the new ad-
dress to appear after the Enter button on the keyboard
is pressed, and the console will be unresponsive during
this time –this is normal.
Activate
keyboard
entry screen.
HiQnet On
Inactive
Active
Enable HiQnet
functionality.
Once the IP address is set and the HiQnet node address
has been confirmed as unique in the network, you can
enable the HiQnet functionality by pressing the ON
button in the far left Vistonics control. Enabling HiQnet
will cause all the Vistonics controls in the section to
change from greyed-out to orange. A list of information
relating to the current HiQnet setup including a green
‘OK’ indicator is now displayed on the left side of the
HiQnet Setup page, indicating a healthy connection.
HiQnet
disabled
HiQnet
Enabled
Содержание Soundcraft Vi2000
Страница 1: ...User Guide v1 1 ...
Страница 13: ...Vi2000 USER MANUAL 3 0 2 3 0 QUICK START 3 0 QUICK START Buttons And Encoders Ganging ...
Страница 14: ...Vi2000 USER MANUAL 3 0 3 3 0 QUICK START 3 0 QUICK START Inputs Controls Input Channel Access ...
Страница 15: ...Vi2000 USER MANUAL 3 0 4 3 0 QUICK START 3 0 QUICK START Fader Pages Output Assignment ...
Страница 16: ...Vi2000 USER MANUAL 3 0 5 3 0 QUICK START 3 0 QUICK START Outputs Control ...
Страница 17: ...Vi2000 USER MANUAL 3 0 6 3 0 QUICK START 3 0 QUICK START Monitoring ...
Страница 18: ...Vi2000 USER MANUAL 3 0 7 3 0 QUICK START 3 0 QUICK START Copy Paste Move LIbrary ...
Страница 19: ...Vi2000 USER MANUAL 3 0 8 3 0 QUICK START 3 0 QUICK START Snapshot Cuelist ...
Страница 20: ...Vi2000 USER MANUAL 3 0 9 3 0 QUICK START 3 0 QUICK START Main Menu System Lexicon FX ...
Страница 26: ...5 0 5 0 Operations Overview Vi2000 USER MANUAL 5 0 Operations Overview 5 0 Operations Overview ...
Страница 68: ...Vi2000 USER MANUAL 7 0 7 0 OUTPUTS 7 0 OUTPUTS Outputs Auxilliaries Groups and LCR Mix busses ...
Страница 94: ...Vi2000 USER MANUAL 10 0 10 0 MONITORING 10 0 MONITORING ...
Страница 172: ...Vi2000 USER MANUAL 17 0 17 0 FX 17 0 FX ...