Seasonal cleaning

At  least  once  per  year,  the  stove,  venting  connectors 

and chimney should be thoroughly cleaned. If the areas are 
found to have an excessive build up of ash or creosote, it is 
recommended to increase the frequency of the cleaning. This 
will extend the life of the appliance and its components. A 

vacuum specifically designed for ash is preferred, however 

a standard “Shop-Vac” with a HEPA filter may also work 

just fine. 

During cleaning, caution must be taken not to damage the 

white / gray colored ceramic combustion package in the rear 

of the firebox. When using a brush in the chimney or venting 

connector, the by-pass damper should be placed in the open 
position to help prevent ash, creosote or other debris from 
falling down onto and around the combustion package. This 
also protects the top of the combustion package from tool 
or brush damage and diverts most of the removed materials 

into the firebox for easy clean-up and removal. Once the 

venting system has been cleaned, remove the first section 

of connector pipe from the appliance flue collar. Carefully 

vacuum the ash and debris from around the sides and top of 
the combustion package. 

The ramp brick must be removed to allow vacuum access 

for cleaning the front portion of the combustion package. 

Always use caution when refueling or when vacuuming 

the firebox and combustion package. Some users have dam

-

aged their combustion package with vacuum cleaner tools, 

and fire pokers. 

the stove

surface

The stove’s exterior surface should be dusted periodi

-

cally with a soft cloth. For more thorough cleaning, wait 
until the stove is cool before using a damp cloth to clean 
any blemishes.

Controls

To  avoid  a  rust  build-up  on  the  inner  surfaces  of  the 

controls,  work  the  controls  back  and  forth  several  times, 
during the summer, or any prolonged period  when you are 
not using your stove.

the Fire Chamber

The inside of the fire chamber should be examined for 

damage to the refractory lining material, grates, and casting. 
If any bricks have been damaged, replace them with Harman 
replacement parts.

Glass - Replacement

If  the stove’s glass is cracked or broken, you must replace 

it  before  operating  your  stove.  Remove  pieces  carefully.  
Replace glass only with Harman replacement glass; do not 
use substitutes.

To replace the glass panel, you will need to remove the 

door. To do this, open the door,  lift it straight up and place 
it on a soft surface, or door stand that is an optional feature 
with the Oakwood.

Carefully remove damaged glass, gasket material, and 

hold down clips (set aside). 

Referring to the diagram, note how  the various compo-

nents of the door system fit together.  Lay the load door face 

down on the soft surface, and install the self adhesive 1/4" 

gasket material around the front face of the glass. Note: this 
glass has a special IR coating on one side. This coating must 
be to the 

outside

 of the stove. The coated side has a label on 

it. The coated side will also show a resistance reading.

Set the glass panel and gasket gently onto the door. In-

stall the hold down clips and tighten with bolts as shown. 
Reinstall door on stove.

Glass - Cleaning

Occasionally, it will be necessary to clean accumulated 

ash from the glass surface; allowing this ash to remain on 
the glass for long periods can result in “etching” due to the 
acidity of the ash. The creosote which accumulates on the 

glass should burn off during your hot fires.

Never  clean  the  glass  while  it  is  hot,  and  do 

not 

use 

abrasive substances. Wash the surface with cool water, and 
rinse thoroughly. You may wish to use a non-abrasive cleaner 

specifically designed for use on stove glass. In any case, dry 

thoroughly before relighting your stove.

MaIntenanCe

Содержание R11

Страница 1: ...E IN THE U S AND CANADA The Oakwood is not approved for mobile home installation IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS C...

Страница 2: ......

Страница 3: ...tions may result in property damage bodily injury or even death Harman Home Heating 352 Mountain House Road Halifax PA 17032 U S A INDEX INDEX Introduction 4 Specifications 5 Operation Building a Fire...

Страница 4: ...catalytic stoves Top loading makes adding wood easier and allows you to view your beautiful fire through the extra large glass door The glass stays cleaner because of specially coated glass and the e...

Страница 5: ...n limits for wood heaters sold after July 1 1990 Weight 440 lbs Flue Size 6 inch Log Length Recommended 21 Max Heating Capacity 2 000 sq ft Average Emissions 2 32 Grams Per Hr Emissions on Low 0 8 Gra...

Страница 6: ...Harman Oakwood Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch SPECIFICATIONS Optional Cooking Gril...

Страница 7: ...y passing a poker back and forth across the grate The andirons keep the fuel from coming into direct con tact with the glass and keep hot coals and embers from spilling out while reloading Never build...

Страница 8: ...ges The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and burned This...

Страница 9: ...etting all the way to the right Be sure the ash pan door is closed and latched Start with a bed of crumpled paper and kindling sized about finger width place several 1 2 25mm 50mm splitpiecesofdrywood...

Страница 10: ...bypass before taking the ashes outside for safe disposal Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor o...

Страница 11: ...pproved by either the CAN CSA B365 standard Canada or NFPA 211 U S Contact your building authority for information if you are interested in reducing clearance distances other than those presented here...

Страница 12: ...12 Harman Oakwood INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Страница 13: ...Harman Oakwood 13 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 14: ...14 Harman Oakwood installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 15: ...rth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with wood weighs...

Страница 16: ...loset or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described later in t...

Страница 17: ...200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x 12 200 mm x 200 mm 200 mm x 300 mm may be used Codes require that solid fuel chimneys extend 3 ft 0 9 m abo...

Страница 18: ...e of the chimney liner and both must be firmly cemented in place with refractory cement Athimble is a masonry pipe which is inserted through the chimney wall and is frequently the preferred method a b...

Страница 19: ...id fuels are burned completely they pro duce water and carbon dioxide However in long slow burns a substantial amount of carbon monoxide may be produced If allowed to build up carbon monoxide which is...

Страница 20: ...Chimney Support Standard Ceiling Installation with Factory Built Chimney Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Col lar Chimney Connector Cathedral Ceiling Installation...

Страница 21: ...Space Three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Pro tection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach F...

Страница 22: ...Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance Listing Ai...

Страница 23: ...ace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer s instructions on insulation and support Floor Protection in Acc...

Страница 24: ...Clearance for Complex ity Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clear ance for NFPA 211 Type Approved Thimbles Floor Protection in Accordance with Solid Fuel Appliance Listing Ch...

Страница 25: ...work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should be examined for damag...

Страница 26: ...check these gaskets from time to time and replace them when necessary The gaskets are made of fiberglass of different sizes obtainable from your Harman dealer and some are fixed in place with a high...

Страница 27: ...n the smoke deflec tor may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Screen smoke...

Страница 28: ...ck 1 90 02490 2 Charcoal 1 90 02490 3 goldenfire 1 90 02490 4 Metallic blue 1 90 02490 5 Honey glo 1 90 02490 10 Mojave red 1 90 02490 12 Forest green 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27...

Страница 29: ...Top 4 00 249105P 11 Top Load Door 3 00 249115P 12 Top Load Handle 2 00 249148 13 Left Side Panel 4 00 249103D 14 Inner Front 4 00 249111S 15 Andiron Qty 2 Req 3 00 249101P Y 16 Front Load Door 4 00 24...

Страница 30: ...31 2 Inlet Brick Right 3 40 00104 Y 31 3 Logo Brick 3 40 00101 Y 31 4 Inlet Brick Left 3 40 00103 Y 31 5 Upper Brick Clip Pkg of 2 1 00 249172 Y 31 6 Rear Brick Clip Pkg of 2 1 00 249153 Y 31 7 Cast L...

Страница 31: ...2494 32 4 Bottom Heat Shield Kit 1 00 02491 Hardware Packages Bolt 5 16 18 x 2 Zinc Plated Carriage Pkg of 25 3 30 4001 25 Y Bushing 3 8 OD X 1 4 OAL Pkg of 5 3 50 00058 5 Y Nut 1 4 20 Zinc Plated Fin...

Страница 32: ...32 Harman Oakwood...

Страница 33: ...Harman Oakwood 33...

Страница 34: ...34 Harman Oakwood notes...

Страница 35: ......

Страница 36: ...Proudly Printed On 100 Recycled Paper...

Отзывы: