6
P P 38+ P e l l e t S t o ve
3-90-08422R34_08/13
in s t a l l i n g
Place the stove on a noncombustible type floor or floor protector
that extends a minimum of 6 inches (152mm) to the front of the
load door opening, 6 inches (152mm) to the sides of the door
opening, and 6 inches to the rear. Floor protection must also
extend 2 inches (51mm) beyond each side of any horizontal flue
pipe. The minimum floor protector material is 20 gauge sheet
metal. Other floor protector materials are ceramic tile, stone,
brick, etc.
NOTE f o r Ca n a d i a n i n s t a l l a t i o n o n l y :
Per ULC-S627-00,
If installed on a combustible floor, the need to provide a
noncombustible
floor protector
covering the area beneath the
space heater
and extending at least 17.72" (450mm) on the firing
side and at least 7.87" (200mm) on the other sides.
In Canada, you may follow smaller U.S. floor protection
r eq u i r em en t s ONLY i f t h e u s er a g r ees t o c o m p l et el y s h u t -
down the appliance, and allow it to cool to where all fire is
ex t i n g u i s h ed a n d t h e c o m b u s t i o n b l o w er a n d i t s i n d i c a t o r
light shuts off, prior to opening the firebox door or ash door.
Place the stove away from combustible walls at least as far as
shown in Figures 3 and 4. Please note the difference in side wall
clearance with and without side shields.
Note that the clearances shown are minimum for safety but do not
leave much room for access when cleaning or servicing. Please
take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that the
stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter. (The
draft meter must have a minimum range of 0 - .5") Record the
first reading. Connect flue pipe to stove and be sure all doors
and windows in the home are closed. Record the second draft
reading_______. If the second reading is more than .05" lower
than the first reading, check for possible restrictions or the need
for outside air (see page 10). For more information on the draft
test procedure, refer to Page 19.
Mo b i l e H o m e in s t a l l a t i o n
When installing this unit in a mobile home, several requirements
must be followed:
1. The unit must be bolted to the floor. This can be done with 1/4"
lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page 9.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile home.
CAUTiON: Th i s a p p l i a n c e m u s t b e ven t ed t o t h e o u t s i d e.
Due to high temperatures, the stove should be placed out of traffic
and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns to
skin and/or clothing.
Young children should be carefully supervised when they are in
the same room as the stove.
Clothing and other flammable materials should not be placed on
or near this unit.
in s t a l l a t i o n
L
J
Fl o o r Pr o t ec t i o n
Req u i r em en t s
US
Canada
Sides
Rear
6"
200mm
6"
200mm
K
Front
6"
450mm
Minimum Size floor protection (USA) is 32
1/2
" wide By
33" deep (825mm X 838mm).
* Floor protection dimensions for the front and sides
are measured from the appliance door opening in
The United States. In Canada, the side dimension is
measured from the widest part of the appliance.
NOTE:
Measurement "L"
is measured from
the pedestal base
in the US ONLY
NOTE:
Measurement "K"
is measured from
the glass in the
US ONLY
W ARNiNG
TH E STRUCTURAL iNTEGRiTY OF TH E MANUFACTURED
H OME FLOOR, W ALL, AND CEiLiNG/ ROOF MUST BE
MAiNTAiNED.
DO NOT iNSTALL iN SLEEPiNG ROOM.
Fi g . 3
9"(228mm)With or w/Out Side Shields
9"(228mm)
9"(228mm)
Alternate floor protector
dimension may be used
as long as they satisfy the
measurement requirements
shown below.
M i n u m u m s i z e f l o o r
protection for a corner
installation hearth pad is
36" x 36". Clearance shown
as 9" with optional side
shields installed.
Fi g . 4
2"(51mm)
36"(914mm)
10" (254mm) with
side shields
16" (406mm)
without side shields
10" (254mm)
16" (406mm)
J
USA
K
L
J
CANADA
F
loor
protector