Harman PC45 Скачать руководство пользователя страница 3

3

pC 45 Corn/pellet Stove

3-90-02686R29_05/14

Assembly and Installation

Fig. 1

unpacking

The PC 45 is bolted to the skid to prevent movement during 

shipping. 
To free the stove from the skid you must remove the hold-

down bolts in the rear of the pedestal base.

removing or Installing rear panels

To remove the rear cover panels, loosen the screws slightly 

and slide the covers outward as shown in Fig 1. To reinstall, 

simply slide back into place and retighten the screws.
If needed, install the (2) 5/16-18 X 3/4” leveling bolts located 

in the hardware kit. Fig 1.

Firebrick

Install the three (3) firebrick vertically on the angle above 

the burnpot. Fig. 2

Follow these instructions along with all local codes regarding 

installation of this appliance. 
Do

 NOT

  use  makeshift  compromises  when  installing  this 

appliance, serious consequences may result.
With any hearth appliance, installation of smoke detectors 

is recommended on every level of the home. 

Possible causes of smoke detector activation:

Paint curing process - Open a window near the appliance 

for the first few hours of burning.
Exhaust being drawn back inside the dwelling - Outside air 

connection to the appliance is necessary.
Vent leakage - All interior seams and joints should be sealed 

with silicone where applicable. Follow vent manufacturers 

instructions for proper sealing.

Fig. 2

Rear Cover 

Panel

Shipping bolts 

Note: These same holes are used for 

securing  the  stove  in  mobile  home 

installation.

Rear Cover 

Panel

Содержание PC45

Страница 1: ...onnaire de Harman Save these instructions Installation Operating Manual Model s PC45 Freestanding Corn Pellet Stove NOTICE SAVE THESE INSTRUCTIONS Hot glass will cause burns Do not touch glass until i...

Страница 2: ...is uniquement Measured from Glass Opening Mesurer partir de la surface de la porte en verre Floor Protection Must Be a Non Combustible Material MustAlso be Place UnderAny Horizontal Flue Connector Ext...

Страница 3: ...e burnpot Fig 2 Follow these instructions along with all local codes regarding installation of this appliance Do NOT use makeshift compromises when installing this appliance serious consequences may r...

Страница 4: ...heck for possible restrictions or the need for outside air For more information on the draft test procedure refer to the draft adjustment procedure located in this manual Mobile Home Installation When...

Страница 5: ...r assembly when measured from the horizontal center line of the regulator V Vent Terminal A Air Supply Inlet Area where termination is not permitted Door Sidewalk Fixed Closed Openable Openable Fixed...

Страница 6: ...corn burning The sections of pipe lock together to form an air tight seal however in some cases a perfect seal is not achieved For this reason and the fact that the PC45 operates with a positive vent...

Страница 7: ...wever consideration must be given to the total house demand House demand may consume the air needed for the stove It may be necessary to add additional ventilation to the space in which the appliance...

Страница 8: ...od This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high and...

Страница 9: ...excellent venting for normal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate Kaowool mineral wool or an equivalent n...

Страница 10: ...Be sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Insta...

Страница 11: ...bustible materials are allowed within 3 of the PL vent pipe flashing storm collar 1 MIN 1 MIN 1 2 M I N 1 MIN Fig 15 12 min wall to outlet 36 min clearance to any combustible material Fig 17 DO NOT IN...

Страница 12: ...with a burn pot that has 125 1 8 combustion air holes This grate has no identifying marks Included with your stove is an additional grate that has 0625 1 16 combustion air holes This grate can be iden...

Страница 13: ...uit board switches The pellet kit contains the instructions for the conversion a new burn pot end gate and a new combustion blower inlet ring The combustion blower inlet ring on the left is the one or...

Страница 14: ...e setting can be adjusted within the full range between 1 on the low side to 6 on the high side Overfeeding is not a safety concern but the fire may be pushed off the burnpot and extinguish in the ash...

Страница 15: ...you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door open NOTE The initial start up on a new stove may require the corn to be purged into the burn...

Страница 16: ...EMP AUTO MANUAL IGNITER FEED ADJUSTER PELLET ONLY C O R N PELLET Manual Stove Temperature Mode Igniter Switch to MANUAL Room Temp Mode The fire will have to be lit with starting gel and a match or sta...

Страница 17: ...ll reset the control and start the combustion motor 3 Turn the Temperature Dial to the desired setting 4 Clean the burnpot and housing if necessary 5 Fill the burnpot with pellets so that the auger tu...

Страница 18: ...when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below Indicates power to Distribution Blower 6 Blinks Indicates that the control has calcula...

Страница 19: ...itch will not allow the feeder motor or the igniter to operate A simple draft test should be performed after completing the flue pipe installation To record the results for future reference Combustion...

Страница 20: ...container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If ashes ar...

Страница 21: ...ombustion blower wheel and flue outlet Fig 33 7 Clean the blower wheel with a brush and a vacuum cleaner Soot and Fly Ash Formation and Need For Removal The products of combustion will contain small p...

Страница 22: ...basic ways 1 Because the corn slag buildup will absorb moisture from the air when cool the parts can just be left exposed for several days and the slag buildup will crumble off of the parts 2 To acce...

Страница 23: ...Lay the glass into the door making sure that the glass is contained within the channels and raised areas of the door itself Lay the glass retainers into position and install the screws Tighten each s...

Страница 24: ...too rich a Feed rate too high b Draft too low caused by a gasket leak 2 Unit is in an ignition cycle Troubleshooting LOW HEAT OUTPUT 1 Feed rate too low 2 Temperature setting too low Stove Temp Mode...

Страница 25: ...fuel with high moisture content takes energy to dry and tends to cool the appliance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through...

Страница 26: ...02686R29_05 14 Specifications 23 1 2 10 35 1 2 5 1 4 12 3 8 29 1 2 Weight 249 lbs Blower 135 CFM Feed Rate 0 to 5 0 lbs per hr Hopper Capacity 80 lbs Fuel Corn Wood Pellets Flue Size 3 Inch Outside Ai...

Страница 27: ...installs behind the trim on the ash door Cleaning Plated Trim Gold or nickel plated hardware should never be buffed or polished Abrasive cleansers and metal polishes will remove the plating and theref...

Страница 28: ...e room sensor is essential for the PC45 s excellent efficiency NOTE It is recommended that the room sensor be installed even if only installed on the rear of the unit as a return air sensor Fig 43 Fig...

Страница 29: ...OUND 18 3 RUBBER CORD N O WHITE BLUE GREEN WHITE GREEN RED ESP PROBE 6 AMP GLASS FUSE PART NO 3 89 02676 BLUE FEEDER AUGER MOTOR PUMP BLACK RED REMOTE SENSOR PORTS IGNITOR ELEMENT MALE FEMALE CONNECTI...

Страница 30: ...e construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs...

Страница 31: ...is warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is...

Страница 32: ...shut down Your appliance will pulse the blower every few seconds to clear exhaust until the fire is out NOTE The UPS provides safe shut down only It is not intended for continued operation Your applia...

Страница 33: ...33 PC 45 Corn Pellet Stove 3 90 02686R29_05 14 Service Maintenance Log Date Of Service Description Of Service Performed By...

Страница 34: ...34 pC 45 Corn pellet Stove 3 90 02686R29_05 14 Service Maintenance Log Date Of Service Description Of Service Performed By...

Страница 35: ......

Страница 36: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Отзывы: