A. Congratulations

Congratulations on selecting a Harman

®

 Freestanding Pellet 

Stove. The Harman

®

 P-Series pellet stove you have selected 

is designed to provide the utmost in safety, reliability, and 

efficiency.
As the owner of a new pellet stove, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This 

owner’s manual

 

should be retained for future reference. 

We  suggest  that  you  keep  it  with  your  other  important 

documents and product manuals.
Your new Harman

®

 P-Series Freestanding Pellet Stove will 

give you years of durable use and trouble-free enjoyment. 

Welcome to the Harman

®

 family!

The model information regarding your specific stove can be found on 

the rating plate usually located in the control area of the stove.

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Welcome  

Brand: ________________________________________________

Model Name:

 ___________________________

Serial Number:

 __________________________________________

Date Installed:

 __________________________

Appliance Information:

Local Dealer Information

DEALER: 

Fill in 

your name, address, 

phone and email 

information here and 

appliance information 

below.

Dealer Name: ________________________________________________________

Address: ____________________________________________________________

               ____________________________________________________________

Phone:   _____________________________________________________________

Email:    _____________________________________________________________

P.N. 3-90-04300

Made in U.S.A. of US and imported parts. / Fabriqué

aux États-Unis-d’Amérique par des pièces d’origine

américaine et pièces importées.

BARCODE LABEL

008

Serial No.

N

o

 de série:

Report #/ Raport #

135-S-23-4, 135-S-23b-6.2

Tested to / Testé à:

 ASTM E 1509-04, 

ULC-S627-00, EPA Method 28 & 5G

MODEL / MODÈLE: “P43”

Room Heater Pellet Fuel-Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

This pellet burning appliance has been tested and listed for use in

Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909

Rev G

MINIMUM CLEARANCES TO COMBUSTIBLES/ DISTANCES DE 

SECURITE PAR RAPPORT AUX MATERIAUX COMBUSTIBLES:

Back Wall / Entre Mur Arrière  2”/ 51mm 

2”/ 51mm

Side Wall / Entre Paroi Latér  16”/ 406mm  10”/ 254mm

CORNER INSTALLATION / EN ANGLE

Walls to Appliance  / 

9”/228mm 

9”/228mm

Entre Murs et appareil

FLOOR PROTECTION / Protection Du Plancher

  

USA

 

Canada

Sides*/Côtés  (A) 

6” 

200mm

Back**/Arrière  (B) 

6” 

200mm

Front*/Avant  (C) 

6” 

450mm

**Measured from pedestal base in the US ONLY

**Mesuré à partir de la base du socle aux États-Unis uniquement

*Measured from Glass Opening 

US ONLY

*Mesurer à partir de la surface de la porte en verre 

CANADA ONLY

Floor Protection Must Be a Non-Combustible Material. Must Also be 

Place Under Any Horizontal Flue Connector, Extending 2” or 51mm 

Beyond the Pipe Measurement.

Pour protéger le plancher, il faut sous le pêole un matériau. Qui doit 

aussi être placé sous les parties horizontales du tuyau de raccord à la 

cheminée et s’étendre à 51mm ø 2 po. au-delà de la mesure du tuyau.

Without

Side Shields
Sans Écrans

Latéraux

With

Side Shields
Avec Écrans

Latéraux

2"(51mm)

10" (254mm) with side shields

16" (406mm) w/out side shields

9”(228mm) 

9"(228mm)

PRotection De Sol

FlooR PRotection

A

cAn

A

USA

c

B

F

loor

 

protector

352 Mountain House Road

Halifax, PA 17032

ECO:  77540
PARt # / REv:  3-90-04300_Rev G
ORiGinAtOR:  Spidlet
DAtE:  04/15
LAbEL SizE:  4-3/8” H. x 10-3/4” W
LOCAtiOn: 

Hopper - top Rear

CLASS: 
ADHESivE: 486
MAtERiAL: MEtAL
ink: bLACk
OvERCOAt:

LAbEL tiCkEt

Corners .062

Room Heater, Pellet Fuel-Burning Type, Also For Use In Mobile Homes. (UM) 84-HUD

“PREVENT HOUSE FIRES”

 Install and use only in accordance with manufactures 

installation and operation instructions.

This wood heater needs periodic inspection and repair for proper operation. Consult 

the owner’s manual for further information. It is against federal regulations to operate 

this wood heater in a manner inconsistent with the operating instructions in the owner’s 

manual.

Contact local building or fire officials about restrictions and installation inspection in 

your area.

WARNING: FOR MANUFACTURED HOMES:

 Do not install appliance in a sleeping 

room. An outside combustion air inlet must be provided. The structural integrity of the 

manufactured home floor, ceiling and walls must be maintained.

Refer to manufacturer’s instructions and local codes for precautions required for 

passing chimney through a combustible wall or ceiling. Inspect and clean exhaust 

venting system frequently in accordance with manufacturer’s instructions.

Use a 3” or 4” diameter type “L” or “PL” venting system.

Do not connect this unit to a chimney flue servicing another appliance.

Do not obstruct the space beneath the heater.

FOR USE WITH PELLETIZED WOOD FUEL ONLY.

Input Rating Max: 5.5 lb. fuel/hr

EPA Certified Emissions: 1.3 g/hr

U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPS

Fuel Type: Wood Pellet.

Route power cord away from unit.

OPERATE ONLY WITH DOORS CLOSED

DANGER:

 Risk of Electrical Shock. Disconnect Power Before Servicing Unit.

For Further Instruction, Refer To Installation and Owner’s Manual.

Replace glass only with 5mm mirrored ceramic available from your dealer.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

Chauffe-chambre, Pellet à combustibles Type, également pour les maisons mobiles. (UM) 84-HUD

“EMPêCHER MAISON INCENDIES”

 Installer et utiliser uniquement en conformité avec les instructions 

du fabricant d’installation et d’exploitation.

Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le 

manuel du propriétaire pour plus d’informations. Ce est contre les règlements fédéraux pour faire fonctionner 

ce poêle à bois d’une manière incompatible avec les instructions d’utilisation dans le manuel du propriétaire.

Contactez le service des incendies à propos des restrictions et l’inspection d’installation dans votre région.

AVERTISSEMENT: POUR MAISONS PRÉFABRIQUÉES:

 Ne pas installer l’appareil dans une chambre à 

coucher. Une entrée d’air de combustion à l’extérieur doit être fournie. L’intégrité structurale de la maison 

étage, plafond et murs fabriqués doit être maintenue.

Reportez-vous aux instructions du fabricant et les codes locaux pour les précautions nécessaires pour 

faire passer la cheminée à travers un mur ou un plafond combustible. Inspectez et nettoyez système 

d’évacuation souvent en conformité avec les instructions du fabricant.

Utilisez un “ou 4” Type de diamètre «L» 3 ou le système de ventilation “PL”.

Ne pas connecter cet appareil à un conduit de cheminée desservant un autre appareil.

Ne pas obstruer l’espace sous le chauffe-eau.

À UTILISER AVEC LA GRANULE DE BOIS SEULEMENT.

Entrée Max Note: £ 5,5 carburant / h

Émissions certifiés EPA: 1,3 g / h

US Note électrique: 115 VAC, 60 Hz, Start 4,2 AMPS, Run 2,8 AMPS

Type de carburant: granulés de bois.

Route cordon électrique de l’appareil.

Fonctionner uniquement avec les portes fermées

DANGER:

 Risque de choc électrique. Débranchez l’alimentation avant l’Unité des services.

Pour de plus amples instructions, reportez-vous à l’installation et le manuel du propriétaire.

Remplacer le verre seulement avec 5mm miroir en céramique disponibles chez votre revendeur.

Ne ENLEVEZ PAS CETTE ÉTIQUETTE / NE PAS CETTE ÉTIQUETTE enlever

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.

Date of Manufacture / Date de fabrication:

2015   2016   2017   JAn   FeB   MAR   APR   MAY   JUn   JUl   AUG   SeP   oct   noV   Dec

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

Serial Number

Model Name

EXAMPLE

Содержание P43

Страница 1: ...enandadultstohazardsofhightemperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and ot...

Страница 2: ...eater needs periodic inspection and repair for proper operation Consult the owner s manual for further information It is against federal regulations to operate this wood heater in a manner inconsisten...

Страница 3: ...gency Manual Ignition 26 E Service Parts 27 P43 27 P61A 31 P68 36 F Contact Information 42 Contains updated information 1 Welcome A Congratulations 2 B Limited Lifetime Warranty 4 2 Product Specific a...

Страница 4: ...f new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whicheve...

Страница 5: ...S This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This...

Страница 6: ...S627 00 ULC ORD C 1482 M1990 UM 84 HUD MODEL P43 Pellet Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 23 4 135 S 23b 6 2 TYPE Pellet Fueled Supplementary For Residential Use STANDARD s...

Страница 7: ...ency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn r...

Страница 8: ...in front or to the sides of the appliance High temperatures may ignite clothing furniture or draperies Mantel Avoid placing candles and other heat sensitive objects on mantel or hearth Heat may damage...

Страница 9: ...r scale marked from 1 to 7 Mode Selector Allows you to choose between Room Temp Mode Constant burn Mode or OFF Also allows you to vary the distribution blower speed by turning the knob to the high or...

Страница 10: ...ing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system NOTICE Hearth Home Technologies is not responsible for stove performance or e...

Страница 11: ...igh After burning approximately 7 10 minutes the appliance will then burn at the rate at which it was originally set If the appliance is set at one of the lower settings it will run quieter but take l...

Страница 12: ...stics test to insure the control is operating properly This is normal 3 For your first fire it may be necessary to purge the auger system by putting the feed limit knob to Test prior to starting the u...

Страница 13: ...temp mode however the blower will turn on and off in accordance to what temperature the room sensor is reading When the room sensor is satisfied the blower will shut down until the room sensor sees a...

Страница 14: ...r element to operate if the view door is open 4 Adjust Feed Limit If this is your first fire or you are trying different pellets set the feed limit to 4 Figure 4 6 This is a conservative number and wi...

Страница 15: ...tant fuel consumption rate is sacrificed for exact room temperature Therefore as it gets colder more pellets will be burned automatically The distribution blower speed will vary according to the posit...

Страница 16: ...hese are recommendations Clean more frequently if you encounter heavy build up of ash at the recommended interval or you see soot coming from the vent Not properly cleaning your appliance on a regular...

Страница 17: ...e self adhesive 1 4 gasket material around the front face of the glass Set the glass panel and gasket gently onto the door Install the hold down clips and tighten with bolts Glass Cleaning Sometimes i...

Страница 18: ...e burn pot This will help knock pieces of ash loosened by the scraping process down through the holes It also helps knock scale off of the igniter element Figure 5 3 The igniter is made to be removabl...

Страница 19: ...ke cover pull towards the front of the unit while sliding to the right Figure 5 6 Now that the combustion intake cover is removed you can remove any flyash or debris that has collected around combusti...

Страница 20: ...16 wing nut Figure 5 8 Lift up and slide the cover off of the threaded stud Inspect and clean the inner chamber if necessary Figure 5 9 Reinstall the cover making certain it is seated properly on the...

Страница 21: ...will not start in AUTO with this status error 5 Blinks In Igniter Auto Mode Only Indicates that the unit has failed to light within the 36 minute start cycle To reset Turn Mode Selector to OFF then tu...

Страница 22: ...it burns on low the more frequent cleaning of the glass is required 4 Glass has turned dirty 4 Excessive build up of ash The lower burn settings will produce more ash the higher burn settings produce...

Страница 23: ...low blocked flue 3 Something is restricting fuel flow 4 Hopper lid not closed properly 5 Feed motor or combustion blower has failed SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich a...

Страница 24: ...iner until all cinders have thoroughly cooled Soot and fly ash Formation and need for removal The products of combustion contain small particles of fly ash The fly ash will collect in the exhaust vent...

Страница 25: ...ty control There are 2 high limits one normal operation high limit and one backup high limit The control has an automatic diagnostic circuit that continuously monitors the ESP and Room Sensor for faul...

Страница 26: ...l remain shut down If the fire is out and the ESP is still warm the feeder may restart Since the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink st...

Страница 27: ...RT NUMBER 1 Hopper Assembly 1 10 04300 Y Hopper Knob Post 008168147 1 00 02000 1 Hopper Lid w Hinge Swell Latch Pre 008168147 1 10 08518 Hopper Lid w Hinge Knob Post 008168147 1 10 773900 Hopper Switc...

Страница 28: ...ake Assembly 1 10 06810A 2 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 2 6 UL Feeder Air Intake 1 10 72222 2 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 2 8 Ultra Feeder Weldment 1 10...

Страница 29: ...0 08516S Y 12 Retainer Assembly 1 10 08533S Y 13 Ash Pan 1 10 7738108A Y 14 Ash Door Assembly Pre 008168147 1 10 7738106A Post 008168147 1 10 773904A Wood Handle Pkg of 3 3 40 08746 3 15 Bolt on Hinge...

Страница 30: ...lpipe Pkg of 5 1 00 07381 Y Gasket Hopper Lid 1 00 00248 Y Gasket Hopper Throat 3 44 677185 Y Gasket Over re Air Burnpot 3 44 724114 Y Glass Clip Pkg of 4 1 00 249140 Y Hopper Muf er and Fitting 1 set...

Страница 31: ...ed at Depot ITEM Description COMMENTS PART NUMBER 1 Hopper Assembly Pre 008085092 1 10 08622 Y Post 008085092 1 10 05803 Hopper Extension Switch Kit 1 00 06826 Y Hopper Knob Post 008093438 1 00 02000...

Страница 32: ...t 1 10 06461 2 3 Feeder Weldment 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Assembly 1 10 06691 Y 2 6 Feed Cover and Gasket 2 Sets 1 00 677152 Y 2 7 Auger Assembly 3 50 00465 Y...

Страница 33: ...r Air Intake Pkg of 6 3 44 72224 6 Y 3 6 UL Feeder Air Intake 1 10 72228 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132 Y 3 9 UL Feeder Pusher Arm 1 10 67...

Страница 34: ...2P Y 12 Comb Intake Weldment 1 10 08516S Y 13 Retainer Assembly 1 10 08533S Y 14 Ash Pan 1 10 05800 Y 15 Ash Door Assembly Pre 008093438 1 10 06724S Post 008093438 1 10 06798A Wood Handle Pkg of 3 3 4...

Страница 35: ...Load Door 30 Ft 1 00 00888 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y Gasket Hopper Lid 1 00 00248 Y Hopper Lid W Hinge Swell Latch Pre 008093438 1 10 09109 Y Hopper Lid w Hinge Knob Post 00809...

Страница 36: ...ed at Depot ITEM Description COMMENTS PART NUMBER 1 Hopper Assembly Pre 008280309 1 10 06709 Y Post 008280309 1 10 00688 Hopper Extention Switch Kit 1 00 06826 Y Hopper Knob Post 008295042 1 00 02000...

Страница 37: ...embly Pre 008280309 1 10 07806 2 1 Air Intake Damper Assembly 1 10 06466W 2 2 Air Intake Weldment 1 10 06461 2 3 Feeder Weldment 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Asse...

Страница 38: ...embly 1 10 06810A 3 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 3 6 UL Feeder Air Intake 1 10 72228 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132...

Страница 39: ...Cover Right 2 00 06468 2P Y 12 Door Latch Assembly 1 00 06713 Y Contains Latch Adjustment SHCS 1 4 20 X 1 Lock Nut 1 4 X 20 Jam Nut HX Jam 1 4 20Z Steel Bushing 13 Comb Intake Weldment 1 10 08516S Y 1...

Страница 40: ...1 00 00959 Y Draft Meter Assembly 1 00 00637 Y Draft Meter Bolt and Tube 1 00 04004 Fuse 6 Amp Pkg of 5 3 20 49447 5 Y Gasket 1 4 Rope Black W PSA Glass 15 Ft 1 00 2312 Y Gasket 3 8 Rope White LD Ash...

Страница 41: ...and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER Leaf Door Trim Gold 3 43 06717 4 Brushed Stainless 3 43 06717 7 B...

Страница 42: ...___________________________________________________________________________ ________________________________________________________________________________ ___________________________________________...