C. Loss of Power

Harman pellet burning appliances rely on a combustion 

blower to remove exhaust from the firebox. A power failure 

will cause the combustion blower to stop running, which 

may lead to exhaust see page into the room. Vertical rise in 

the venting system can help create natural draft, which may 

reduce the likelihood of exhaust leakage into the home.

Installation of a low-cost uninterruptible power supply (UPS) 

or battery backup system can help ensure the units shuts 

down without any minor smoke leakage into the home. 

Harman recommends the installation of one of these two 

systems for areas prone to power outages.

There is one Harman® approved UPS option for your 

appliance:

Uninterruptible Power Supply UPS

 battery back-ups are 

available online or at computer and office equipment stores. 

Your  Harman®  appliance  with  Rev  E  or  later  software 

available beginning in November 2010 may be plugged 

directly into a Harman® approved UPS:

• 

TrippLite model INTERNET750U

 is tested and 

approved.  Other  brands  or  models  may  not  be 

compatible.

When power is lost, a fully charged UPS will power a safe, 

combustion  blower  only  shut-down.  Your  appliance  will 

pulse the blower every few seconds to clear exhaust until 

the fire is out.

 NOTE: The UPS provides safe shut-down 

only. It is not intended for continued operation.

•  A  Inverter/Charger  connects  to  a  12  volt  deep  cycle 

battery that will run your appliance for up to eight (8) 

hours. It includes a trickle charge feature that keeps your 

battery charged when power is available. 

NOTE:

 If the 

power is out for longer than battery life, smoke leakage 

may still occur unless your stove has been safely shut 

down.

For an approved Inverter/Charger refer to www.

harmanstoves.com.

Your appliance will recognize when power is restored. What 

happens  depends  on  ESP  temperature  and  whether  it  is 

equipped with automatic ignition:

 

In “Automatic” Mode

, units equipped with automatic 

ignition will respond to the set point and ESP temperature 

and resume normal operation.

• 

In “Idle” Mode

, or for units without automatic ignition:

•  If  the  ESP  is  cool,  the  appliance  will  remain  shut 

down.

•  If the fire is out and the ESP is still warm, the feeder 

may restart. Since the fire is out, the ESP temperature 

will not rise. The unit will then shut-down, and may 

flash a six-blink status error. (See ESP error codes)

•  If  the  fire  is  still  burning,  it  will  resume  normal 

operation.

Contact  your  dealer  if  you  have  questions  about  UPS 

compatibility with your appliance.

IMPORTANT! :

 UPS or Battery Backup cannot prevent smoke 

leakage from an improperly maintained unit. Keep the venting 

system clean and free from obstructions and maintain all 

gaskets to keep an airtight seal.

Use only Harman

®

 approved battery back-up devices. 

Other products may not operate properly, can create 

unsafe conditions or damage your appliance.

CAUTION

Always keep appliance doors and hopper lid closed 

and latched during operation and during power 

failures to minimize risk of smoke or burn-back.

D. Emergency Manual Ignition

Harman

®

 pellet stoves and inserts should be lit using the 

automatic ignition system. This is the safest and most 

reliable way for igniting the unit.  In the event the automatic 

igniter is not functioning, the steps below may be followed 

to manually light the stove or insert in the “Constant Burn” 

mode.  Manual  lighting  is  for  emergency  purposes  only, 

and the igniter should be repaired or replaced as soon as 

practical.

WARNING

Only  use  firestarter  commercially  marketed  for  pellet 

stoves  and  inserts,  including  wax  coated  wood  chips, 

pellet  starter  gel  and  pellet  igniter  blocks.  Use  of  any 

other type of firestarter is prohibited.

To  avoid  serious  injury  or  death  read  and  follow 

manufacturer’s warning and instructions for use of firestarter. 

Use of firestarter is only permitted when performing a cold 

start.
Never attempt to manually light a stove or insert that has 

been operated recently and is not at room temperature. 

If  automatic  ignition  was  attempted,  be  sure  to  give  the 

stove or insert at least 30 minutes or longer to cool to room 

temperature.

Be sure that the stove or insert is in the “Igniter - Disabled” 

mode of operation.

Once  all  the  precautions  have  been  taken,  follow  these 

steps:

1.  On  the  touch  control,  select  the  Burn  Mode  icon  then 

select “Constant Burn”.

2.  Arrow back and select the Igniter icon then select “Manual” 

for the ignition method. Select the Home Icon to go back 

to the Main Menu.

3.  Fill burn pot with pellets, only half way. (Do Not Over Fill).

4.  Add firestarter to pellets following manufacturer’s 

instructions.

5.  Light pellet gel with a match, and close the door, touch 

the On/Off icon on the home screen. Operation will begin 

when the fire reaches the proper temperature.

WARNING

Содержание P42i-TC

Страница 1: ...y cause house fire WARNING Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove Al...

Страница 2: ...Burning Type Also For Use In Manufactured Homes UM 84 HUD PREVENT HOUSE FIRES Install and use only in accordance with the manufacturer s installation and operation instructions Contact local building...

Страница 3: ...18 B Limited Lifetime Warranty 25 C Loss of Power Addendum 27 D Emergency Manual Ignition 27 E Troubleshooting 28 F Contact Information 30 1 Product Specifications and Important Safety Information A...

Страница 4: ...Hopper Capacity 64 5 lbs Fuel Wood Pellet NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Weight...

Страница 5: ...ba org safety information To prevent unintended operation when not using your stove for an extended period of time summer months vacations trips etc Unplug stove from receptacle Due to high temperatur...

Страница 6: ...evacuate the residence Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors Carbon Mono...

Страница 7: ...AND COULD RESULT IN A HOUSE FIRE USE ONLY APPROVED FUELS AND FOLLOW ONLY THESE OPERATION GUIDELINES WARNING NEVERUSEGASOLINE GASOLINE TYPELANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILARLIQUID...

Страница 8: ...per with pellets Initial start up Only 1 Select Language 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations Please Note The US...

Страница 9: ...flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the airwash Bu...

Страница 10: ...u did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue to heat...

Страница 11: ...oot coming from the vent Not properly cleaning your appliance on a regular basis will void your warranty Note Do not use a household vacuum to clean the stove We recommend that you use a shop vacuum t...

Страница 12: ...into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugged fro...

Страница 13: ...nthly cleaning Monthly cleanings will ensure proper operation of your unit throughout the heating season Cleaning Glass Once unit is cold use a non abrasive glass cleaner on glass and wipe clean Scrap...

Страница 14: ...of the burn pot grate Simply push the allen wrench down through each hole ensuring it is clear of any build up paying attention not to damage the igniter element in the process Figure 2 6 Disconnect...

Страница 15: ...e the high temperature igniter wires WARNING Clean Ash Accumulation Figure 2 9 Yearly Maintenance Cleaning the Combustion Fan Chamber Remove the combustion cover assembly Figure 2 11 To do this pull u...

Страница 16: ...periods can result in etching due to the acidity of the ash Never clean the glass while it is hot and do not use abrasive substances Wash the surface with cool water and rinse thoroughly You may wish...

Страница 17: ...place thoroughly vacuum around the Distribution Blowers Figure 2 17 Figure 2 17 Distribution Blower Cleaning Venting System It is recommend that a certified chimney sweep perform service and inspectio...

Страница 18: ...Material Service Parts P42i TC Beginning Manufacturing Date May 2023 Ending Manufacturing Date Active Part number list on following page Pellet Insert 1 90 742200 1 20 Hopper 03 23 1 90 742240 1 24 H...

Страница 19: ...ol Board 1 00 05372 Y 9 Control Board Mounting Plate 1 10 584012A 10 Differential Switch 3 20 6866 Y Silicone Tubing 1 8 5 Ft 1 00 5113574 Y 11 Hinge Set 4 pc Side Panel 2 Sets SRV8742 7890 12 Surroun...

Страница 20: ...ts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER 29 Feeder Assembly See following page 30 Distribution Blower 3 21 33647 Y 18 1 Burn Pot Weldment w Cradle 1 00...

Страница 21: ...ontrol 1 00 777552 Y Touch Control Screws Pkg of 30 SRV8787 011 Cable Cover Gasket 3 44 777549 20 2 Screw Post Kit Set of 20 1 00 129004 Y 20 3 Hopper Lid Knob w Screw Black 1 00 02000 1 20 4 Touch Co...

Страница 22: ...rts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER 21 1 Wooden Handle w Bolt Pkg of 2 1 00 00247 21 2 Door Latch Painted 3 00 249119P Y Door Latch Roller Hardwa...

Страница 23: ...Y 29 4 Gasket UL Feeder Cover 1 00 677122 Y 29 5 5 16 18 wing screw Pkg of 25 3 30 8012 25 29 6 UL Feeder Pusher Arm 1 10 677187W Y 29 7 UL Feeder Auger Assembly 3 50 00565 Y 29 8 Cam Block Assembly...

Страница 24: ...on COMMENTS PART NUMBER Burn Pot Scraper Pkg of 10 2 00 777692 10 Communication Cable 3 20 72662 Y Draft Meter Assembly 1 00 00637 Y Draft Meter Bolt Tube 1 00 04004 Fuse Ceramic 5A Pkg of 5 1 00 0523...

Страница 25: ...tallation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from the beginning date of warranty cov...

Страница 26: ...as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicabl...

Страница 27: ...not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Contact your dealer if you have questions...

Страница 28: ...iled Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell Seal th...