background image

www.harmanstoves.com    

!"#

Service Parts

Oakwood

Beginning Manufacturing Date: N/A 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION

. Parts must be ordered from a dealer or 

distributor. 

Hearth and Home Technologies does not sell directly to consumers

. Provide 

model number and serial number when requesting service parts from your dealer or distributor.

Stocked 

atDepot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

17

Ash Lip

3-00-249121P

18

Ash Fender Bolt Plate

Qty 2 req

2-00-249169L

19

Wood Knob

Pkg of 3

3-40-08746-3

20

Ash Door

4-00-249113D

Ash Door Latch Hardware

1-00-24923

Y

Ash Door Latch 

3-00-249149

Ash Door Gasket

5 Ft

1-00-43375

Y

Ash Door Hinge

2-00-249150

21

Hinge Stiffener

2-00-249188L

22

Ash Pan

1-10-249151

Y

23

Steel Ash Box Weldment

1-10-249144S

24

Ca Shield

2-00-249157B

25

Leg

Qty 4 req

4-00-249100P

Y

26

Bottom

4-00-249104D

27

Right Side Panel

4-00-249102D

28

Damper Frame Assembly w/Gasket

1-10-249106

Y

Gasket

30 Ft

1-00-00888

Y

Damper  w/Adjuster

1-10-249107

Damper Linkage

1-10-249146

Y

Damper Shaft Retainers and Hardware

1 Set

1-00-249145

Y

Adjuster w/Hardware

Pre  00726440

1-00-249142

Y

Post  008426440

1-00-250153

Air Slide Assembly

30.1

Air Adjuster Pipe

Qty 2 req

2-00-249158S

30.2

Air Adjuster Weldment

1-10-249130S

30.3

AirSlide Weldment

1-10-249131W

31.1

Back Heat Shield Kit -Top Vent

1-00-02492

31.2

Back Heat Shield Kit - Rear Vent

1-00-02493

31.3

Outside Air Option

1-00-02494

31.4

Bottom Heat Shield Kit

1-00-02491

Additional service part numbers appear on following page.

ƒ‰

ƒ‰‚

ƒ‰ƒ

#30 Air Slide assembly

#31 Flue Shield 
Asembly

ƒ

ƒ‚

ƒƒ

ƒ„

Содержание Oakwood

Страница 1: ...ntire manual before installation and use of this wood burning room heater Failure to follow these instructions could result in property damage bodily injury or even death 0 1 0 2 3 41 0 5 6 0 3 2 7 2...

Страница 2: ...ons and local codes for precautions required for passing chimney through a combustible wall or ceiling This wood heater needs periodic inspection and repair for proper operation Consult the owner s ma...

Страница 3: ...2 2 2 2 2 2 2 12 5 Chimneys and Venting C2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 7 0 7 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 72 F 2 2...

Страница 4: ...D 6 9D7 6 FC K 558 2 2 EPA BTU Output 6 BTU Input 6 Vent Size 4 Recommend Log Lenght 5 Fuel 7 Q HI FLHQF EDVHG RQ 3 KLVWRULFDO GDWD RI FWXDO WHVWHG HI FLHQF DQG GDWD FROOHFWHG GXULQJ 3 HPLVVLRQV WHVW...

Страница 5: ...UR AREA WARNING THIS WOOD HEATER HAS A MANUFACTURER SET MINIMUM LOW BURN RATE THAT MUST NOT BE ALTERED IT IS AGAINST FEDERAL REGULATIONS TO ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD HEATER IN...

Страница 6: ...rances may only be reduced by means approvedbytheregulatoryauthorityhavingjurisdiction 3 1 06 1 2 4 1 0 2 0 1 2 8 1 6 02 2 C 0 7 C 3 5 3 1 2 2 C 6 1 2 2 C 0 3 1 4 1 0 3 2 02 2 10 8 2 2 0 0 3 2 2 3 Get...

Страница 7: ...nt Locations D Flue Direction Conversion 1 Z 1 5 2 8 1 2 8 6 0 2 3 5 0 6 1 2 6 1 1 02 0 2 E 11 2 2 Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handl...

Страница 8: ...SUBSTITUTE COMPONENTS REPORT DAMAGED PARTS TO DEALER WARNING FIRE RISK HEARTH HOME TECHNOLOGIES DISCLAIMS ANY RESPONSIBILITY FOR AND THE WARRANTY WILL BE VOIDED BY THE FOLLOWING ACTIONS WARNING INSTAL...

Страница 9: ...Dry Seasoned Wood Only Oakwood Woodburning Stove 9 3 90 08327 A Appliance Dimensions 4 Dimensions Clearances 24 15 16 18 1 16 21 24 3 4 26 1 4 21 7 1 2 30 1 4 30 1 2 when rear vented...

Страница 10: ...eduction methods refer to NFPA 211 or Local Codes Follow NFPA 211 Table 13 6 1 Clearances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested f...

Страница 11: ...ods refer to NFPA 211 or Local Codes Follow NFPA 211 Table 13 6 1 Clearances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested for installati...

Страница 12: ...ods refer to NFPA 211 or Local Codes Follow NFPA 211 Table 13 6 1 Clearances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested for installati...

Страница 13: ...s refer to NFPA 211 or Local Codes Follow NFPA 211 Table 13 6 1 Clearances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested for installation...

Страница 14: ...allation Rear Flue 6 Single Wall Pipe _ weight limitations 1 0 3 5 1 2 6 5 0 2 Side Wall 37 940mm 22 559mm 16 406 5mm 2 75 70mm 26 660 5mm Mantel Extends over 3 4 from the wall Trim Extends less than...

Страница 15: ...EH SURWHFWHG H WHQGLQJ WZR LQFKHV EH RQG WKH PHDVXUHPHQW RI WKH KRUL RQWDO FRQQHFWRU 8 1 1 4 92 2 0 6 5 1 1 6 2 4 7 6 5 1 1 6 5 2 DANGER 0 1 2 Parallel versus Corner Installations C 1 1 2 C 1 0 1 2 1...

Страница 16: ...1 0 0 0 1 G 6 3 1 0 2 1 1 1 6 0 3 6 1 0 2 4 0 1 0 6 G 6 0 6 1 2 6 0 1 0 2 B Chimney Connectors 4 6 1 0 6 0 13 0 1 0 0 2 0 2 0 2 G 1 G 1 2 1 2 1 0 0 1 6 6 2 6 1 0 6 6 2 K K K K 7 C 6 0 2 Z 6 I 0 1 2 0...

Страница 17: ...connector and wall Non combustible cover one side only If two covers are used each must be mounted on non combustible spacers at least 7 8 21mm away from the wall 1 25mm Clearance Minimum 2 50mm Clear...

Страница 18: ...1 0 2 1 0 2 7 8 F 2 0 3 5 6 0 0 2 41 0 3 0 6 0 0 0 02 0 0 6 3 2 8 5 6 0 6 6 6 1 3 02 Installing to a Prefabricated Chimney 1 06 6 1 1 I H DFWO 2 9 0 1 I 1 2 C 1 0 92 2 7 6 9D 9D7 2 Other Consideration...

Страница 19: ...Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shield SS SSS SSS SSS SSS SSS SSS...

Страница 20: ...required air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non combustible material Com...

Страница 21: ...insulated clean out Flue liner with required air space Floor Protection Stainlesssteel chimney connector must extend to flue liner Minimum 8 masonry thickness in front of smoke chamber Use damper ada...

Страница 22: ...r other approved lining system Floor Protection Follow liner manufacture s instructions on insulation and support UL1777 insulated stainless steel flex liner or other approved lining system in offsets...

Страница 23: ...Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior c...

Страница 24: ...FOR SLEEPING WARNING MAINTAIN STRUCTURAL INTEGRITY OF MOBILE HOME FLOOR WALL CEILING AND OR ROOF DO NOT CUT THROUGH FLOOR JOIST WALL STUDS OR CEILING TRUSSES ANY SUPPORTING MATERIAL THAT WOULD AFFECT...

Страница 25: ...1 2 2 5 1 2 7 5 2 2 5 1 2 2 1 5 1 2 0 1 0 8 2 2 1 3 2 2 5 6 2 B Leveling the Appliance Z 6 0 3 2 6 2 C Optional Cooking Grill 0 1 2 3 7 2 6 2 6 0 C 2 6 0 3 G 0 2 6 0 0 0 2 0 0 5 3 6 0 12 7 Appliance...

Страница 26: ...7 E Bottom Heat Shield F 2 1 1 1 02 1 2 D 1 2 D Optional Rear Shield 6 A A 6 0 0 2 F 11 2 Slide heat shield in from the rear of the unit F Optional Cozy Screen 1 3 2 6 7 G0 1 2 0 2 7 G0 1 1 3 5 2 3 7...

Страница 27: ...perating Instructions CAUTION Approved for use with wood fuel only The use of any other fuel will void the product warranty and may cause damage to the appliance and or your home NEVER USE GASOLINE GA...

Страница 28: ...1 2 1 1 6 1 2 3 0 2 The grates and andirons must remain in place at all times Do not tamper with or change the Doors E 1 3 6 1 2 Front Door 1 6 0 1 6 6 0 0 1 1 2 6 0 3 6 6 6 6 6 2 Ash Door 6 1 2 7 0 0...

Страница 29: ...OPERATION F Building and Maintaining a Fire 0 6 5 6 0 2 2 1 G 3 1 0 1 6 1 0 1 2 D 0 5 2 4 2 C 3 1 1 6 0 2 C 3 1 G 6 1 0 3 5 2 7 1 2 C 0 1 3 0 1 6 5 0 1 1 2 You must have this charcoal bed established...

Страница 30: ...1 2 3 5 1 6 0 1 0 2 41 0 1 3 6 0 3 6 2 4 1 0 3 6 0 3 0 1 0 1 2 1 0 1 2 3 2 0 0 1 0 1 0 2 C 0 0 6 0 Z 6 1 1 3 2 1 2 1 6 0 2 0 6 0 1 0 2 7 0 1 1 1 2 Ashes should be placed in a metal container with a t...

Страница 31: ...Creosote Formation and Need For Removal 06 5 1 2 0 0 1 3 2 C 6 2 6 5 0 3 2 0 0 0 1 2 41 6 1 0 3 2 7 0 10 3 2 0 3 6 3 5 02 0 0 0 1 2 0 1 6 6 5 3 2 0 0 6 6 5 2 1 06 0 5 2 6 6 1 5 0 2 41 6 5 1 0 2 F 1 1...

Страница 32: ...te on the glass may lead to permanent fogging or crazing of the glass 4 2 2 2 6 6 0 0 2 3 1 0 0 2 0 1 6 0 0 3 2 D 0 6 2 0 0 2 Ashes must be placed in a metal container with a tight disposal If the ash...

Страница 33: ...ebox Frequency C 0 E 0 By 9 7 3 5 5 1 13 02 0 0 1 1 6 0 0 1 02 0 1 2 1 1 2 C 0 1 2 Chimney Connector Frequency C 0 E 0 By 3 9 C 1 6 1 0 2 0 1 11 2 C 0 1 0 2 0 0 1 2 0 6 0 2 0 1 1 8 2 Chimney Frequency...

Страница 34: ...allic Blue Ending Manufacturing Date Jan 2010 1 90 02490 1 Black 1 90 02490 12 Forest Green Ending Manufacturing Date Jan 2010 1 90 02490 13 Enamel blue Ending Manufacturing Date Jan 2010 1 90 02490 1...

Страница 35: ...Elbow Painted 3 50 00500S Y 7 Cook Grill Assembly Optional 1 00 08121 8 Flue Collar 4 00 249108D 9 Top Hinge Plate Qty 2 req 2 00 249147S 10 Top 4 00 249105P Gasket 30 Ft 1 00 00888 Y 11 Top Load Door...

Страница 36: ...nge Stiffener 2 00 249188L 22 Ash Pan 1 10 249151 Y 23 Steel Ash Box Weldment 1 10 249144S 24 Ca Shield 2 00 249157B 25 Leg Qty 4 req 4 00 249100P Y 26 Bottom 4 00 249104D 27 Right Side Panel 4 00 249...

Страница 37: ...rate 2 00 249122 Y 32 9 Cast Right Inside Plate w Gasket 1 10 249118A Y 32 10 Rear Brick Retainer Pkg of 2 1 00 249135 32 11 Shoe Brick 3 40 00100 Y Gasket shoe Brick 10 Ft 1 00 11862 Y 32 12 Side Bri...

Страница 38: ...6 6 6 2 6 6 0 1 0 1 0 1 1 1 1 12 5 0 1 2 0 Z 6 5 2 WARRANTY PERIOD 0 1 2 4 1 6 0 1 1 0 1 5 1 1 0 6 G 6 2 0 1 1 1 6 1 0 2 0 1 1 1 2 D D 1 1 0 1 1 0 1 6 0 1 1 0 1 6 6 2 1 5 1 1 2 6 5 6 5 2 F D F FC 7 A...

Страница 39: ...6 6 6 1 6 1 2 4 1 0 0 1 2 5 1 6 0 0 0 2 0 0 1 0 0 6 0 1 2 7 F F A4 E DC 6 CB F C C 4 C C C E F 7484 4 2 9 C 4 8 C E 4 FD4 C C E 4 D4 4 9 C 4 8 F C C E F 7484 C A 2 WARRANTY EXCLUSIONS 0 1 7 1 1 1 2 C...

Страница 40: ...Oakwood Woodburning Stove Dry Seasoned Wood Only 3 90 08327 Service Maintenance Log _ _...

Страница 41: ...Oakwood Woodburning Stove Dry Seasoned Wood Only 41 3 90 08327...

Страница 42: ...www harmanstoves com 6 1 K 6 1 56 FC 2 2 F 0 0 2 8 1 0 6 2 2 2 NOTES 3ULQWHG LQ 8 6 DO NOT DISCARD THIS MANUAL NOTICE D 0 1 2 4 2 6 1 1 1 2...

Отзывы: