Harman Martin MAC Ultra Wash Скачать руководство пользователя страница 15

Fixture setup

 15

Fixture setup

The onboard control panel lets you configure the fixture using a range of fixture settings. Note that many of 
these settings are also available on the Control / settings DMX channel (see “Adjusting settings via DMX” on 
page 20).

Fixture ID

The fixture lets you set a four-digit ID number to ease identification of the fixtures in an installation. When a 
fixture is powered on for the first time, it displays its DMX address by default. As soon as you set an ID 
number other than 

0

 in 

FIXTURE ID

, the fixture will display this ID number by default, and indicate 

FIXTURE 

ID

 in the display.

Personality

The 

PERSONALITY

 menu provides several options that let you customize the fixture for different 

applications:

• The 

PAN/TILT

 menu offers the following options:

-

PAN INVERSE 

and

 TILT  INVERSE 

let you invert the direction of pan and tilt movement. This can be a 

fast way of setting symmetrical action in multiple fixtures with no need to reprogram cues.

-

FOLLOWSPOT MODE 

disables the pan and tilt motors so that you can move the head manually using 

the integrated handles on the back of the head. 

Warning! 

The head becomes hot during use. Make sure that it is impossible for operators to burn 

themselves. 

When you disable followspot mode, the fixture resets pan and tilt and the head returns to its original 
position.

The pan and tilt motors are completely disabled to give the smoothest head movement with maximum 
freedom, but you must support the head constantly while in followspot mode (unless you apply 

TOGGLE HOLD POSITION

 in the shortcuts menu as described below). If you let go of the handles, the 

head will sink under gravity to a tilt down position. 

- Using the shortcuts menu that opens if you hold the MENU button pressed in for 2 - 3 seconds (see 

“Shortcuts” on page 10), a followspot operator can quickly put the fixture into followspot mode and also 
use the 

TOGGLE HOLD POSITION 

feature. Applying 

TOGGLE HOLD POSITION

 while the fixture is in 

followspot mode uses the pan and tilt motors to hold the head in its current position. This menu item lets 
the followspot operator quickly toggle between free head movement and static head position.

-

LIMIT PAN/TILT

 lets you define minimum and maximum limits for pan and tilt angles so that you can 

install fixtures close to obstacles (such as other fixtures or trusses) with no risk of collision, so that the 
beam will only hit a certain area of a stage or set, or so that you can avoid the fixture shining into the 
eyes of the audience.

PAN MIN 

and 

TILT MIN 

set minimum limits for pan and tilt, and 

PAN MAX

 and 

TILT MAX

 likewise set 

maximum limits. The fixture’s pan and tilt movement will remain in a ‘safe zone’ within the limits that you 
set.

- To set the limits using the control panel menus, go into the 

LIMIT PAN/TILT

 menu and enter the 

minimum and maximum limits for pan and tilt as the 16-bit values that you would use to move pan 
and tilt to those positions via DMX. The range of values available is -32767 to 32768.

- To set the limits via DMX, move the head using the pan and tilt DMX channels to the position where 

you want to set minimum pan and tilt limits, then enable

 Pan minimum

 and 

Tilt minimum 

limits on the 

Control/Settings DMX channel, sending values for at least 1 second to activate them. Use the same 
method to set the maximum pan and tilt limits.

Note that when you power the fixture off, the head may move under its own weight to a position that is 
outside its pan and tilt limits.

RESET PAN/TILT LIMITS

 sets the fixture to default pan and tilt limits that are suitable for mounting the 

fixture in a GT Pre-Rig truss using standard Martin half-coupler rigging clamps. If you install the fixture 
in this type of pre-rig truss, you only need to execute a 

RESET PAN/TILT LIMITS

 command and set 

LIMIT ENABLE

 to 

ON

 to avoid the risk of head collisions.

Содержание Martin MAC Ultra Wash

Страница 1: ...MAC Ultra Wash User Guide...

Страница 2: ...affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the info...

Страница 3: ...ntrol options 11 DMX 11 P3 video 11 RDM 12 Fixture setup 15 Fixture ID 15 Personality 15 Managing fixture settings 17 Fixture information readouts 18 Temperatures 18 DMX signal monitoring 18 Test sequ...

Страница 4: ...ge dimming with four dimming curve options Electronic shutter effect with variable speed regular and random strobe CMY color mixing Continuously variable Color Temperature Control from 6000 to 2850 K...

Страница 5: ...up suddenly Check that no one is looking at the fixture from close range The fixture does not have an On Off switch To apply power to the fixture connect the power input cable to a source of AC power...

Страница 6: ...eed from approx 1 Hz to 20 Hz Dimming Smooth 0 100 overall dimming is available with 16 bit control resolution Four dimming curves are available see Figure 3 on page 16 Color mixing The fixture featur...

Страница 7: ...m angle Linked zoom focus works within 3 distance ranges close medium and long range The ranges are as follows figures are approximate Close 5 10 meters 16 5 33 ft Medium 10 20 meters 33 66 ft Long 20...

Страница 8: ...channel Once activated the corresponding FX Speed and Direction channel will control the LED PWM frequency Note that this change is not stored permanently in the fixture so you have to keep the FX Sel...

Страница 9: ...a menu or make a selection The currently selected item in a menu is indicated by a star Press the MENU button C to step backwards through the menus Status LED The LED F next to the control buttons ind...

Страница 10: ...ost important commands appears Select a command with the UP and DOWN buttons D and press the ENTER button E to activate or press the MENU button C again to cancel RESET ALL resets the whole fixture RO...

Страница 11: ...the other networked fixtures in the daisy chain will not be interrupted Data rate Any Ethernet switch used to relay Art Net streaming ACN or P3 data to the MAC Ultra Wash must be capable of running at...

Страница 12: ...icate over standard DMX cable and over Art Net and sACN Ethernet links using RDM Remote Device Management in accordance with ESTA s American National Standard E1 20 2006 RDM is a bi directional commun...

Страница 13: ...DEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS SOFTWARE_VERSION_LABEL DMX Setup DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DMX_START_ADDRESS SLOT DESCRIPTION Sensors SENSOR_DEFINITI...

Страница 14: ...EFFECT_SHORTCUT_ENABLE DISPLAY_ERRORS_ENABLE DIMMER_CURVE VIDEO_TRACKING FOCUS_TRACKING DISPLAY_AUTO_OFF HIBERNATION_MODE TUNGSTEN_MODE Pan tilt PAN_TILT_SPEED PAN_TILT_LIMITATION_ENABLE PAN_LIMITATI...

Страница 15: ...an quickly put the fixture into followspot mode and also use the TOGGLE HOLD POSITION feature Applying TOGGLE HOLD POSITION while the fixture is in followspot mode uses the pan and tilt motors to hold...

Страница 16: ...to display video the processing can interfere with video response times If you enable video tracking the fixture does not smooth out input but instead snaps instantly when a value changes For best res...

Страница 17: ...asily no matter how the fixture is oriented TEMPERATURE UNIT lets you choose whether the fixture should display all temperature readings in Celsius or Fahrenheit ERROR MODE enables or disables error w...

Страница 18: ...for troubleshooting control problems RATE displays the DMX refresh rate in packets per second Values lower than 10 or higher than 44 may result in erratic performance especially when using tracking c...

Страница 19: ...in the DMX protocol in this User Manual When you exit the MANUAL CONTROL menu the fixture will keep its effect positions and settings until you enter a new menu When you do this the fixture will reve...

Страница 20: ...ivity To bring it out of sleep mode set the display to ON again via DMX Control menu setting overrides The following fixture settings can be adjusted via DMX overriding the settings entered in the onb...

Страница 21: ...and hold for 5 seconds to exit the DMX calibration procedure and return to normal DMX control Calibration offsets that are stored in memory are not affected by powering the fixture off and on or by up...

Страница 22: ...14 15 16 29 30 31 44 45 46 59 60 61 74 75 76 89 90 91 104 105 160 161 163 164 166 167 169 170 172 173 175 176 178 179 192 193 214 215 221 222 243 244 247 248 251 252 255 Color wheel Indexing Split co...

Страница 23: ...ed by power off on Inverse square law dimming curve 1 sec menu override setting unaffected by power off on S curve dimming curve 1 sec menu override setting unaffected by power off on No function Fast...

Страница 24: ...on 5 sec Store zoom calibration 5 sec Store color wheel calibration 5 sec No function Return all calibration settings to factory defaults 5 sec No function Snap 0 P3 Mix 24 0 26 27 28 227 228 229 255...

Страница 25: ...et shift 120 Offset shift 130 Offset shift 140 Offset shift 150 Offset shift 160 Offset shift 170 Offset shift 180 Offset shift 190 Offset shift 200 Offset shift 210 Offset shift 220 Offset shift 230...

Страница 26: ...address RESET IP SETUP RESET ARE YOU SURE YES NO Reset static IP address and subnet mask to default values FIXTURE ID 0 9999 User settable 4 digit fixture ID number default 0 PERSONALITY PAN TILT PAN...

Страница 27: ...ensity fans run at full speed light intensity reduced if necessary to keep fixture within temperature limits CONSTANT FAN MEDIUM Fans run at medium speed light intensity reduced if necessary to keep f...

Страница 28: ...s 3 SAVE ARE YOU SURE YES NO Save fixture s current settings as Custom Settings 3 INFORMATION POWER ON TIME TOTAL 0 XXX HR Display hours fixture has been powered on since manufacture not user resettab...

Страница 29: ...X 2 then enter a value from 0 to 255 one channel or 0 to 65535 two DMX channels 256 x 256 to apply a command FX 2 ADJUST 0 255 FX SYNC 0 255 Select FX SYNC then enter a value from 0 to 255 to manually...

Страница 30: ...on USB memory device UPDATING FILES Fixture updating internal memory from USB memory device AVAILABLE FIRMWARE XX XX XX XX XX XX Select firmware from versions stored in internal memory Scroll to selec...

Страница 31: ...when the user reacts to the warning If more than one warning is detected all warnings are displayed in sequence If the display is inactive the fixture s status LED see Figure 2 on page 9 flashes orang...

Страница 32: ...rface LCD display and control panel PCB sensor detects abnormally high operating temperature ZFTW ZF TEMP HIGH Zoom focus PCB sensor detects abnormally high operating temperature Short code Long messa...

Страница 33: ...e to correct pan position but pan movement will often still be possible FBET TILT FBACK ERR Tilt position magnetic indexing system timeout Fixture is unable to correct tilt position but tilt movement...

Страница 34: ...ng a firmware upload Error cleared when new firmware is uploaded successfully or power is cycled off and on UELD UPL ERR LED DRV Could not upload new LED driver software during a firmware upload Error...

Страница 35: ...www martin com...