36
MAC Ultra Performance User Guide
Service and display messages
The MAC Ultra Performance gives service and maintenance information by displaying a large 3- or
4-character short code and a smaller full-text message in the fixture’s display. The short code is visible at a
distance, allowing easier reading with the fixture still in the rig, for example, while the full-text message gives
more detailed information.
Excessively high temperatures
If any of the temperature sensors reports that the fixture has exceeded its recommended temperature
range, the fixture reports a temperature warning and reduces light output to reduce its temperature. If the
temperature reaches a dangerous level, light output is shut down completely.
Temperature warnings are canceled and full light output becomes available again as soon as the
temperature returns to normal.
Warning messages
Warning messages indicate that either:
• problems might appear in the future if no action is taken, or
• the user needs to pay special attention to a function or procedure when working with the fixture.
The MAC Ultra Performance communicates warnings as follows:
• Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
• If more than one warning is detected, all warnings are displayed in sequence.
• If the display is inactive, the fixture’s status LED (see Figure 5 on page 12) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
The possible warning messages are listed in Table 3 below
:
Short code
Long message and explanation
BANK
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BATM
BATTERY MODE
Fixture in battery mode. Certain control menu items are not available.
BETW
BEAM TMP HIGH
LED beam pixels sensor detects abnormally high operating temperature.*
CMTW
CMY TEMP HIGH
CMY module sensor detects abnormally high operating temperature.*
EFTW
EFF TEMP HIGH
Effects module sensor detects abnormally high operating temperature.*
F2TW
FRAMING2 TMP HIGH
Framing module sensor 2 detects abnormally high operating temperature.*
FRTW
FRAMING TMP HIGH
Framing module sensor 1 detects abnormally high operating temperature.*
FTNA
FROST ADJUST
Frost effect out of adjustment range.
G11M
GOBO 1-1 MISSING
Gobo Wheel 1: Gobo 1 not detected.
G11M
GOBO 2-1 MISSING
Gobo Wheel 2: Gobo 1 not detected.
Table 3: Warning messages