background image

 

 

Exterior Wash 200 Series 

User manual 

 

Содержание Martin Exterior Wash 200 Series

Страница 1: ...Exterior Wash 200 Series User manual...

Страница 2: ...direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin is a registered trad...

Страница 3: ...5 Protecting connections from moisture 15 Connecting to power 15 Control data link 17 Connecting the data link 17 Setup 19 Accessing and navigating the control menus 19 DMX settings 19 Programming a s...

Страница 4: ......

Страница 5: ...trate the beam Do not look at operating light source Eye injury may result This fixture presents risks of severe injury or death due to burn and fire hazards electric shock and falls if the safety pre...

Страница 6: ...ner Shut down power to the entire installation at the main power distribution board and lock out power before carrying out any installation or maintenance work Use only a source of AC power that compl...

Страница 7: ...nation light intensity can increase and you should consult a lighting professional for more appropriate safety recommendations Exterior Wash 200 The Exterior Wash 200 is classed Risk Group 3 according...

Страница 8: ...ed staring into the light output at less than 14 1 m 46 3 ft from the fixture is not expected Protection from injury Fasten the fixture securely to a fixed surface or structure when in use The fixture...

Страница 9: ...over plate to deter unauthorized access They are prepared for hard wiring with 1 8 m 5 9 ft cables for power and data connection Fixture overview 1 Front ring with recessed channel for optional diffus...

Страница 10: ...erials The fixture can become hot Restrict public access or locate the fixture so that it cannot accidentally be touched Mounting the fixture Warning All fasteners used to mount Exterior Wash 200 Seri...

Страница 11: ...mps secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable will hold the fixture if a rigging clamp fails Loop the...

Страница 12: ...r Nominal diffuser beam angle Effective beam angle 210 model Effective beam angle 200 220 models None 10 7 Narrow 91610154 10 14 12 Medium 91610153 20 22 21 Wide 91610152 40 41 40 Very Wide 91610151 6...

Страница 13: ...can be installed on the front of the fixture in two orientations See illustrations below If a diffuser lens is installed on the front of the fixture install the louver with the profile facing outwards...

Страница 14: ...of the snoot fits into the front of the fixture see arrows in illustration below Line up the snoot correctly making sure that screw holes in the snoot line up with threaded holes in the front of the f...

Страница 15: ...shut down power to fixtures that is easily accessible and is located close to the fixtures Do not use an external dimming system to supply power to the fixture as this may cause damage to the fixture...

Страница 16: ...If you install a power plug on the power cable for temporary use install a grounding type earthed plug with integral cable grip that is rated minimum 277 V 6 A Follow the plug manufacturer s instruct...

Страница 17: ...and the end of each branch by placing a 120 ohm resistor available from Martin P N 04150308 across the data output hot ve and data output cold ve conductors of the last fixture in the chain Avoid crea...

Страница 18: ...into contact with a connector shell as this may cause interference Wires Input pair red tube Output pair black tube Shield Color white green white brown black Signal DMX in DMX in DMX out DMX out com...

Страница 19: ...ol of the red green blue and white LEDs Since fixtures are uncalibrated slight differences in color and or intensity between different fixtures may be visible in the light output from multiple fixture...

Страница 20: ...me type and set to the same DMX control mode may share the same address and control channels if identical behavior is desired The DMX address may be set from the control panel or by RDM To set the fix...

Страница 21: ...g when the fixture is mounted upside down flip the display as follows 1 Access the control menu and select DISPLAY SETTINGS Press ENTER 2 Select DISPLAY INVERSE and press ENTER 3 Select YES to invert...

Страница 22: ...esistor across data hot and data cold in the data IN connector of the first fixture DMX and RDM signals will override standalone operation in both the host and the client fixtures This means that stan...

Страница 23: ...en it is not receiving a control signal from either a DMX controller or a host fixture SHOW MODE Fixture executes its standalone show fixture must be set to HOST If the fixture is set to HOST and it d...

Страница 24: ...Press and hold the MENU button to access the control menu 2 If prompted for a password press the arrow buttons to scroll to the current 3 digit password or the service password 111 Press ENTER when th...

Страница 25: ...o not use products that contain solvents abrasives or caustic agents for cleaning as they can cause surface damage to the fixture The aluminum housing and front glass can be cleaned with mild detergen...

Страница 26: ...t on the PC 3 Connect the Martin Companion Cable to the DMX data link using an XLR connector or screw terminals see Connecting the data link on page 17 for wire colors and pinouts 4 Launch the Martin...

Страница 27: ...the ability to control overall intensity level on DMX channel 1 Output is not calibrated Channel Value Function 1 0 255 Dimmer 0 100 2 0 255 Red 0 100 3 0 255 Green 0 100 4 0 255 Blue 0 100 5 0 255 W...

Страница 28: ...hannels 1 and 2 Channel 3 provides color temperature control from warm to cold at maximum output When set to a level above 26 channel 3 overrides channels 1 and 2 Channel Value Function 1 0 255 Warm W...

Страница 29: ...10 Red 0 255 Manually adjust output Green 0 255 Blue 0 255 White 0 255 Manual Mode 220 Warm White 0 255 Manually adjust output Cold White 0 255 Display Setting Display Inverse No Yes Flip display Disp...

Страница 30: ...Config contd DMX State Show Mode Behavior when no DMX control signal present Hold Last Look Black Out Display Lock No Yes Password protect control menu Lock Password 0 999 123 Set user password Facto...

Страница 31: ...X link defective Check number of DMX channels required by each fixture and check DMX addresses on fixtures and DMX controller Verify CHANNEL MODE setting Inspect connections and cables Correct poor co...

Страница 32: ...00 K 6500 K Control and Programming All models Control systems DMX RDM Setting addressing standalone programming Control panel with OLED display Receiver RS 485 Firmware update Serial upload via DMX l...

Страница 33: ...er 12 Medium diffuser 21 Wide diffuser 40 Very wide diffuser 60 Asymmetric diffuser 60 x 12 Photometric Data All models CRI 70 CCT white LEDs 6500 K Exterior Wash 200 Total luminous output 6500 lumens...

Страница 34: ...1 5 A 148 W PF 0 99 120 V 60 Hz 1 3 A 146 W PF 0 99 230 V 50 Hz 0 7 A 146 W PF 0 95 277 V 60 Hz 0 6 A 146 W PF 0 88 Exterior Wash 220 100 V 60 Hz 1 6 A 162 W PF 0 99 120 V 60 Hz 1 4 A 160 W PF 0 99 2...

Страница 35: ...num P N 90509091 Specifications subject to change without notice For latest product specifications see www martin com Disposing of this product Martin products are supplied in compliance with Directiv...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...www martin com...

Отзывы: