ERA 500 Hybrid IP Safety and Installation Manual

• If the level is below 45%, the fixture will run the dehumidification program for 30 seconds.

The fixture will then stop the dehumidification program and the control panel display will return to the 
main menu page.

Note that you can stop the dehumidification process at any time by selecting EXIT in the control panel 
and pressing ENTER to confirm.Note also that, for safety reasons, you cannot run the dehumidification 
process if the fixture is too hot (above 65° C or 149° F).

6. If the fixture is receiving a DMX signal, it will begin to obey DMX control. If no DMX signal is present, the 

fixture will go to standby.

7. Shut down power the fixture. Check that the pressure relief valves and their O-rings are clean, dry and in 

perfect condition. If in any doubt, replace the valves with new items. Reinstall the valves, tightening them 
to 0.6 - 0.8 Nm.

8. When the fixture is powered on again it will no longer be in Service mode: pan and tilt will no longer be 

immobilized.

Vacuum testing

To be sure that the fixture’s IP65 rating is maintained, it is necessary to vacuum test the fixture after 
reassembly each time you have removed a cover (including the rear cover during lamp replacement or lamp 
readjustment). You will need the following items:

• Vacuum tester – you can obtain a suitable tester from Martin (see “Related Items” on page 26).

• M12 x 1.5 adapter, available from Martin (see “Related Items” on page 26), to connect the tester to the 

fixture.

• Vacuum pump with a minimum capacity of 30 liters per minute that can create a vacuum of minimum 

10 kPa (0.1 bar), maximum 50 kPa (0.5 bar). Suitable pumps are available commercially – the instructions 
supplied with the vacuum tester include some suggested products.

• Two M12 x 1.5 nylon or steel blanking plugs with rubber seals. Suitable blanking plugs are available 

commercially.

When you test the fixture, follow the instructions supplied with the vacuum tester. Disconnect any cables 
that are connected to the fixture. See Figure 9. Install all the connectors’ rubber seals 

A

. Remove the two 

pressure relief valves 

B

 on the sides of the head and replace them temporarily with two M12 x 1.5 blanking 

plugs. Remove the pressure relief valve 

C

 on the connections side of the base and screw the M12 x 1.5 

vacuum tester adapter with its O-ring seal into this valve’s threaded hole.

After testing is complete, remove the tester adapter and blanking plugs. Check that the rubber seals on the 
pressure relief valves are in perfect condition and that the valves are perfectly clean. If in any doubt, replace 
the valves with new items. Reinstall the valves, tightening them to 0.6 - 0.8 Nm.

Figure 9: Preparing for a vacuum test

B

C

A

A

Содержание Martin ERA 500 Hybrid IP

Страница 1: ...ERA 500 Hybrid IP Safety and Installation Manual...

Страница 2: ...for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Marti...

Страница 3: ...9 AC power 11 Power input 11 Data links 13 DMX and RDM 13 Service and maintenance 14 Managing humidity 14 Pressure relief valves 15 Dehumidifying the fixture 15 Vacuum testing 16 Cleaning 17 Lubricati...

Страница 4: ...RA 500 Hybrid IP check the Martin website and make sure that you have the latest user documentation for the fixture Document revisions are indicated at the bottom of page 2 This product is for profess...

Страница 5: ...hat are accessible and live at high voltage while the fixture is connected to power and that remain under tension for up to five minutes after power is disconnected Wait for at least five minutes afte...

Страница 6: ...8 under worst case conditions At a distance of less than 19 2 m 63 ft from the fixture the light output can potentially cause eye or skin injury before an exposed person s natural aversion responses b...

Страница 7: ...8 2 17 Section 17 6 6 or BGV C1 DGUV 17 and must be capable of bearing a static suspended load at least six times or more if required by locally applicable regulations the weight that it secures Elimi...

Страница 8: ...for complex projections and mid air effects For the latest firmware updates documentation and other information about this and all Martin products please visit the Martin website at http www martin co...

Страница 9: ...or shade the head so that the front lens will not be exposed to sunlight or another strong light source from any angle even for a few seconds See Figure 1 The ERA 500 Hybrid IP s lens can focus the s...

Страница 10: ...rom a stable platform hang the fixture on the truss with the front facing towards the area to be illuminated Tighten the rigging clamps 5 See Figure 5 Install a safety cable that is approved as a safe...

Страница 11: ...urce The power cable can be hard wired to a building installation circuit or fitted with a mains plug cord cap to allow connection to local AC mains power outlets If you install a mains plug on the po...

Страница 12: ...h clicks and that the connector is locked into the socket 3 If operating outdoors in wet conditions or in conditions where condensation may appear ensure that all cables arrive from below connectors C...

Страница 13: ...ot overload the DMX data link You can connect up to a maximum of 32 devices on a serial DMX link Install a DMX termination plug on the last fixture on the link Connecting to data via DMX cable To conn...

Страница 14: ...rface see Related Items on page 26 and the Martin Companion software suite available for download free of charge from the Martin website at www martin com All other service operations on the ERA 500 H...

Страница 15: ...ronment where airborne dust or dirt is present we recommend that you replace the valves with their rubber seals each time you replace the lamp If heavy dust or dirt is present and the fixture is power...

Страница 16: ...ent You will need the following items Vacuum tester you can obtain a suitable tester from Martin see Related Items on page 26 M12 x 1 5 adapter available from Martin see Related Items on page 26 to co...

Страница 17: ...head by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub the surface hard lift particles off with a soft repeated press Dry with a soft clean lint f...

Страница 18: ...create a safety hazard Replacement lamps are available from Martin see Spare parts on page 26 The lamp bulb and reflector must be perfectly clean when you install the lamp Do not touch them with your...

Страница 19: ...wed on the left hand side of the lamp compartment just above the horizontal lamp adjustment screw Do not confuse the two screws the lamp slider locking screw is smaller than the horizontal lamp adjust...

Страница 20: ...sealed to its original IP65 level carry out a vacuum test as described in Dehumidifying the fixture on page 15 19 Each time you install a new lamp reset the lamp lifetime counter in the fixture s cont...

Страница 21: ...ear cover fan is disconnected 7 See Figure 15 Turn the two Torx 20 lamp adjustment screws A for vertical adjustment and B for horizontal adjustment until you obtain the most even projection 8 Shut dow...

Страница 22: ...fore applying power to the fixture Read the safety information section of this manual starting on page 4 Read Connecting to power on page 11 Check that the installation is safe and secure Check that t...

Страница 23: ...ERA 500 Hybrid IP on the data link Incorrect addressing of fixtures Check fixture address and protocol settings One of the fixtures is defective and is disturbing data transmission on the link Unplug...

Страница 24: ...Motorized Pan 540 coarse fine control and speed Tilt 260 coarse fine control and speed Control and Programming Control options DMX RDM 16 bit control Dimming pan and tilt Setting and addressing Contr...

Страница 25: ...perature steady state at Ta 40 C 60 C 140 F Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 20 C 4 F Maximum total heat dissipation calculated 10 2120 BTU hr Allow for...

Страница 26: ...n Companion software suite incl firmware uploader Free download from www martin com Martin Companion Cable USB DMX hardware interface P N 91616091 Martin RDM 5 5 Splitter P N 90758150 Martin Vacuum Te...

Страница 27: ...nformity for this product The Declaration of Conformity is available for download from the ERA 500 Hybrid IP area of the Martin website at www martin com Canadian Interference Causing Equipment Regula...

Страница 28: ...www martin com...

Отзывы: